1SDA070768R1 ABB E1.2N 800 Ekip Hi-Touch LSI 3-Pole Fixed Air Circuit Breaker

1SDA070768R1 ABB E1.2N 800 Ekip Hi-Touch LSI 3-Pole Fixed Air Circuit Breaker

ABB 1SDA070768R1 is an Emax 2 E1.2N 800 A three-pole fixed air circuit breaker with front terminals and an Ekip Hi-Touch LSI electronic trip unit for advanced overload, selective short-circuit and instantaneous short-circuit protection in low-voltage power-distribution systems.

SKU: 1SDA070768R1MPN: 1SDA070768R1
Price
List Price £9,529.87 ex VAT
Your Price (ex VAT) Save 25%
£7,147.40 25% OFF
You save £2,382.47 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,147.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,147.40

Why Choose the ABB 1SDA070768R1 E1.2N 800 Ekip Hi-Touch LSI Air Circuit Breaker?

The ABB 1SDA070768R1 is a SACE Emax 2 E1.2N 800 three-pole fixed air circuit breaker equipped with an advanced Ekip Hi-Touch LSI electronic trip unit. Designed for demanding low-voltage power-distribution systems, it combines an 800 A rated current with advanced electronic protection, measurement and power-management capabilities.

This configuration features front terminals and the E1.2N performance level, providing a 66 kA breaking capacity and robust short-circuit performance for industrial, commercial and infrastructure switchboards. Its compact E1.2 construction provides high electrical performance while supporting efficient integration into modern low-voltage assemblies.

The Ekip Hi-Touch LSI release provides long-time overload, selective short-circuit and instantaneous short-circuit protection. The Hi-Touch platform extends the capabilities of the Emax 2 electronic protection system with advanced measurement and monitoring functions, making the breaker particularly suitable for installations requiring sophisticated protection and power-system supervision.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution.
  • 800 A rated current in the compact E1.2 frame.
  • Ekip Hi-Touch LSI electronic trip unit with advanced protection and monitoring capabilities.
  • 66 kA breaking capacity for high-performance fault protection.
  • LSI protection supports selective coordination within complex distribution networks.
  • Three-pole fixed construction with front terminals for practical switchboard integration.

Key Features

  • ABB SACE Emax 2 air circuit breaker.
  • E1.2N 800 configuration.
  • 800 A rated current.
  • 690 V rated voltage.
  • Three-pole construction.
  • Fixed execution.
  • Front terminals.
  • Ekip Hi-Touch LSI electronic trip unit.
  • LSI protection: long-time overload, selective short-circuit and instantaneous short-circuit protection.
  • Designed for advanced protection, measurement and supervision of low-voltage power systems.

Advanced LSI Protection and Power-System Supervision

The Ekip Hi-Touch LSI electronic trip unit provides comprehensive current-based protection for sophisticated low-voltage distribution networks. Long-time protection responds to sustained overload conditions, selective short-circuit protection enables delayed fault clearing to support coordination between protective devices, and instantaneous protection rapidly disconnects severe short-circuit faults.

Combined with the E1.2N air circuit-breaker platform, the ABB 1SDA070768R1 provides high fault-interruption performance in a compact fixed configuration. Its front terminals facilitate integration into compatible switchboards, while the Hi-Touch electronic platform makes this breaker particularly suitable for installations requiring advanced protection, electrical measurement and power-system monitoring.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power-distribution systems.
  • Commercial building electrical distribution.
  • Transformer and feeder protection.
  • Critical power and infrastructure installations.
  • OEM switchboards requiring advanced LSI protection and power-system supervision.

Technical Specifications

Product family SACE Emax 2
ABB order code 1SDA070768R1
Product type Air circuit breaker
Frame E1.2
Performance level N
Rated current 800 A
Rated voltage 690 V
Number of poles 3
Execution Fixed
Terminal type Front terminals
Trip unit Ekip Hi-Touch LSI
Protection functions LSI
Breaking capacity 66 kA
Short-time withstand current 50 kA
Product dimensions (W × H × D) 296 × 210 × 183 mm
Standard / approval IEC
Country of origin Italy
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA070768R1?

The ABB 1SDA070768R1 is a SACE Emax 2 E1.2N 800 three-pole fixed air circuit breaker with front terminals and an Ekip Hi-Touch LSI electronic trip unit.

What is the current rating of ABB 1SDA070768R1?

The E1.2N 800 configuration has a rated current of 800 A.

What protection functions does the Ekip Hi-Touch LSI trip unit provide?

The LSI configuration provides long-time overload protection, selective short-circuit protection and instantaneous short-circuit protection.

What is the breaking capacity of the E1.2N 800?

The E1.2N 800 configuration has a 66 kA breaking capacity.

What is the short-time withstand current of the E1.2N 800?

The E1.2N 800 configuration has a 50 kA short-time withstand current.

Is ABB 1SDA070768R1 fixed or withdrawable?

The ABB 1SDA070768R1 is a fixed Emax 2 air circuit breaker with front terminals.

What is the rated voltage of ABB 1SDA070768R1?

The ABB 1SDA070768R1 has a 690 V rated voltage.

Where is ABB 1SDA070768R1 typically used?

Typical applications include industrial and commercial main distribution boards, transformer and feeder protection, infrastructure power systems and OEM switchboards requiring advanced LSI protection and monitoring.

Trusted by Electrical Professionals Worldwide

ABB SACE Emax 2 air circuit breakers are used in demanding industrial, commercial and infrastructure power systems where dependable fault protection, selective coordination, advanced electronic functionality and robust low-voltage switching performance are essential.