1SDA070762R1 ABB E1.2N 800 Ekip Dip LSI 3P F F Air Circuit Breaker

1SDA070762R1 ABB E1.2N 800 Ekip Dip LSI 3P F F Air Circuit Breaker

ABB 1SDA070762R1 E1.2N 800 is an 800 A three-pole fixed SACE Emax 2 air circuit breaker with front terminals and an Ekip Dip LSI electronic trip unit for overload, selective short-circuit and instantaneous protection.

SKU: 1SDA070762R1MPN: 1SDA070762R1
Price
List Price £5,798.17 ex VAT
Your Price (ex VAT) Save 25%
£4,348.63 25% OFF
You save £1,449.54 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,348.63
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,348.63

Why Choose the ABB E1.2N 800 Ekip Dip LSI 3P F F Air Circuit Breaker?

The ABB E1.2N 800 Ekip Dip LSI 3P F F, order code 1SDA070762R1, is an 800 A three-pole fixed air circuit breaker from the ABB SACE Emax 2 range. It combines the compact E1.2 frame with an Ekip Dip LSI electronic trip unit, providing long-time overload, short-time selective and instantaneous short-circuit protection for low-voltage AC distribution systems.

The E1.2N performance level delivers an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC. Its rated short-time withstand current reaches 50 kA for 1 s, providing the fault-withstand performance required for demanding main distribution and feeder applications.

Rated at 800 A with an operational voltage up to 690 V AC, this model uses a fixed three-pole construction with front, bolt-type terminals. The breaker is fitted with four auxiliary contacts and open/closed position indication, while its Ekip Dip LSI release provides the additional short-time protection function needed for selective coordination in appropriately designed distribution systems.

Key Advantages

  • Genuine ABB SACE Emax 2 air circuit breaker.
  • 800 A rated uninterrupted current.
  • 66 kA ultimate breaking capacity at 400–440 V AC.
  • 50 kA ultimate breaking capacity at 500–690 V AC.
  • 50 kA short-time withstand current for 1 s.
  • Ekip Dip LSI electronic release for overload and short-circuit protection.
  • Short-time selective protection supports coordinated distribution-system design.
  • Three-pole fixed configuration with front terminals.
  • Suitable for systems operating at up to 690 V AC.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 800 A rated current.
  • Ekip Dip LSI electronic trip unit.
  • Long-time (L) overload protection.
  • Short-time selective (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Three-pole construction.
  • Fixed (F) execution.
  • Front (F) terminal connection.
  • Bolt-type main terminals.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Suitable for 690 V IT networks.
  • Four auxiliary contacts with open/closed position indication.

Reliable LSI Protection for Selective Power Distribution

The Ekip Dip LSI trip unit combines three essential protection functions. Long-time protection responds to sustained overload currents, short-time selective protection provides controlled operation during short-circuit conditions to assist discrimination with downstream devices, and instantaneous protection rapidly interrupts severe short-circuit faults.

Together with the E1.2N frame's 66 kA ultimate breaking capacity at 400–440 V AC and 50 kA short-time withstand current for 1 s, this makes the 1SDA070762R1 suitable for demanding distribution networks. Its fixed construction, 800 A current rating and front bolt terminals provide a robust configuration for permanent installation in industrial and commercial switchboards.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Commercial building electrical distribution.
  • Main incomer and feeder protection.
  • Selective and coordinated distribution networks.
  • Manufacturing and process plant switchgear.
  • Motor control centres and power distribution panels.
  • Infrastructure and compatible 690 V IT distribution systems.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA070762R1
Product type Air circuit breaker
Frame E1.2
Short-circuit performance level N
Rated current (In) 800 A
Rated uninterrupted current (Iu) 800 A
Number of poles 3
Current type AC
Trip unit Ekip Dip LSI
Release type Electronic
Protection functions Long-time (L), short-time selective (S), instantaneous (I)
Installation version Fixed
Terminal connection Front
Terminal type Bolt
Recommended main-circuit screw M10
Tightening torque 45 N·m
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400–440 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–690 V AC 50 kA
Rated service short-circuit breaking capacity (Ics) at 400–690 V AC 50 kA
Rated short-time withstand current (Icw) 50 kA for 1 s; 30 kA for 3 s
Power loss 50 W
Electrical durability 8000 cycles
Mechanical durability 20,000 cycles
Suitable for IT networks Yes, up to 690 V
Dimensions (W × H × D) 210 × 296 × 183 mm
Net weight 14 kg
Standard IEC
EAN 8015644746124
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA070762R1?

The ABB 1SDA070762R1 is an E1.2N 800 A three-pole fixed SACE Emax 2 air circuit breaker with front terminals and an Ekip Dip LSI electronic trip unit.

What protection functions does the Ekip Dip LSI provide?

The Ekip Dip LSI provides long-time (L) overload, short-time selective (S) short-circuit and instantaneous (I) short-circuit protection.

What is the breaking capacity of the ABB E1.2N 800?

The breaker has an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC.

What is the short-time withstand rating of the ABB 1SDA070762R1?

The breaker has a rated short-time withstand current of 50 kA for 1 s and 30 kA for 3 s.