1SDA070747R1 ABB E1.2B 800 Ekip G Touch LSIG 800 A 3-Pole Fixed Air Circuit Breaker

1SDA070747R1 ABB E1.2B 800 Ekip G Touch LSIG 800 A 3-Pole Fixed Air Circuit Breaker

ABB 1SDA070747R1 E1.2B 800 is an 800 A three-pole fixed SACE Emax 2 air circuit breaker with front terminals and an Ekip G Touch LSIG electronic trip unit for generator protection and low-voltage power distribution.

SKU: 1SDA070747R1MPN: 1SDA070747R1
Price
List Price £8,526.71 ex VAT
Your Price (ex VAT) Save 25%
£6,395.03 25% OFF
You save £2,131.68 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,395.03
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,395.03

Why Choose the ABB E1.2B 800 Ekip G Touch LSIG 3-Pole Air Circuit Breaker?

The ABB 1SDA070747R1 is a SACE Emax 2 E1.2B air circuit breaker designed for generator protection and demanding low-voltage power distribution applications. Rated at 800 A, this three-pole circuit breaker combines the compact E1.2 frame with ABB's advanced Ekip G Touch LSIG electronic trip unit.

The Ekip G Touch LSIG trip unit provides long-time (L), short-time (S), instantaneous (I) and ground-fault (G) protection functions. The Ekip G Touch platform also provides generator-oriented power protection capabilities, making this configuration particularly suitable for generating sets and electrical systems where advanced protection and monitoring are required.

The 1SDA070747R1 features a three-pole fixed (F) construction with front terminals (F) and an R800 rating configuration. The E1.2B platform provides a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC and a rated short-time withstand current of 42 kA for 1 s, providing dependable performance for generator and low-voltage distribution switchboards.

Key Advantages

  • Advanced ABB SACE Emax 2 E1.2B air circuit breaker for generator and low-voltage distribution applications.
  • 800 A rated current for high-current electrical systems.
  • Ekip G Touch LSIG electronic trip unit with generator-oriented protection functionality.
  • Long-time, short-time, instantaneous and ground-fault protection in a single trip unit.
  • 42 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 42 kA short-time withstand current for 1 s.
  • Three-pole fixed construction for permanent switchboard installation.
  • Front terminals provide an accessible connection arrangement for compatible switchgear.

Key Features

  • ABB SACE Emax 2 E1.2B 800 air circuit breaker.
  • 800 A rated current.
  • 690 V rated voltage.
  • Three-pole construction.
  • Fixed (F) installation.
  • Front (F) terminals.
  • Ekip G Touch LSIG electronic trip unit.
  • R800 rating configuration.
  • L protection: long-time overload protection.
  • S protection: short-time short-circuit protection.
  • I protection: instantaneous short-circuit protection.
  • G protection: integrated ground-fault protection.
  • Generator-oriented power protection functionality.
  • Fitted with four auxiliary change-over contacts.
  • Includes circuit-breaker open/closed position indication.

Advanced Generator Protection with Ekip G Touch

The ABB Ekip G Touch platform extends conventional circuit protection with functions intended for generator and advanced power applications. In addition to the core LSIG functions, Ekip G Touch supports generator-oriented power protections, helping protect generating equipment and associated electrical distribution systems against a wider range of abnormal operating conditions.

Combined with the E1.2B 800 circuit-breaker platform, the 1SDA070747R1 provides an 800 A fixed protection solution with 42 kA short-circuit breaking capability at 440 V AC. Its front-terminal arrangement makes it suitable for permanent integration into appropriately designed generator panels, industrial switchboards and low-voltage distribution assemblies.

Typical Applications

  • Low-voltage generator protection systems.
  • Generator switchboards and control panels.
  • Emergency and standby generation systems.
  • Industrial power generation installations.
  • Low-voltage main distribution switchboards.
  • Manufacturing and process plant power systems.
  • Infrastructure and critical-power installations.
  • Three-phase systems requiring LSIG and generator-oriented protection.

Technical Specifications

Series SACE Emax 2
Order code 1SDA070747R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Frame E1.2
Performance level B
Rated current 800 A
Rated voltage 690 V
Number of poles 3
Installation Fixed (F)
Terminal type Front (F)
Trip unit Ekip G Touch LSIG
Rating configuration R800
Protection functions Long-time, short-time, instantaneous and ground-fault (LSIG)
Rated ultimate short-circuit breaking capacity at 440 V AC 42 kA
Rated short-time withstand current 42 kA for 1 s
Overload release adjustment range 320–800 A
Short-time short-circuit adjustment range 480–8000 A
Instantaneous short-circuit adjustment range 1200–12000 A
Integrated ground-fault protection Yes
Auxiliary contacts 4 change-over contacts
Open/closed position indication Yes
Motor drive Optional
Net weight 14 kg
EAN 8015644745974

Frequently Asked Questions

What is the ABB 1SDA070747R1?

The ABB 1SDA070747R1 is a SACE Emax 2 E1.2B 800 three-pole fixed air circuit breaker with front terminals and an Ekip G Touch LSIG electronic trip unit.

What is the rated current of the ABB E1.2B 800?

The ABB E1.2B 800 is rated at 800 A and is designed for generator protection and high-current low-voltage power distribution applications.

What protection functions does the Ekip G Touch LSIG provide?

The Ekip G Touch LSIG provides long-time, short-time, instantaneous and ground-fault protection, together with additional generator-oriented power protection functionality.

What is the short-circuit performance of the ABB E1.2B 800?

The E1.2B 800 has a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC and a rated short-time withstand current of 42 kA for 1 s.

What mounting and terminal configuration does the ABB 1SDA070747R1 use?

The 1SDA070747R1 has a fixed (F) three-pole construction with front (F) terminals for permanent integration into compatible low-voltage switchgear.

Advanced Generator Protection from ABB

ABB SACE Emax 2 circuit breakers with Ekip G Touch protection combine robust short-circuit performance, advanced electronic protection and generator-oriented functionality for dependable operation in demanding low-voltage power systems.