ABB 1SDA070741R1 is an Emax 2 E1.2B 800 A three-pole fixed air circuit breaker with front terminals and an Ekip Dip LI solid-state electronic trip unit for overload and instantaneous short-circuit protection in low-voltage AC power-distribution systems.
£3,325.42
The ABB 1SDA070741R1 is a SACE Emax 2 E1.2B 800 three-pole fixed air circuit breaker with front terminals and an Ekip Dip LI solid-state electronic trip unit. Designed for AC low-voltage power distribution, it combines an 800 A rated current with dependable overload and instantaneous short-circuit protection in a compact E1.2 frame.
This E1.2B configuration provides a 42 kA ultimate short-circuit breaking capacity at 400–440 V AC, with the same 42 kA rating maintained up to 690 V AC. It also provides a 42 kA short-time withstand current for 1 second and 24 kA for 3 seconds, supporting robust performance in industrial and commercial distribution systems.
The Ekip Dip LI release provides long-time overload and instantaneous short-circuit protection. The breaker is supplied with four auxiliary contacts and circuit-breaker open/closed position indication, providing useful status interfaces for compatible switchboard control and monitoring arrangements.
The Ekip Dip LI electronic trip unit provides the fundamental protection functions required in many low-voltage distribution systems. Long-time protection responds to sustained overload conditions, while instantaneous protection rapidly disconnects severe short-circuit faults, helping protect conductors, switchgear and connected equipment.
Combined with the E1.2B air circuit-breaker platform, the ABB 1SDA070741R1 provides robust fault-interruption capability in a fixed three-pole format. Front terminals support practical switchboard connection, while the supplied auxiliary contacts and open/closed position indication facilitate integration with compatible control and status-monitoring systems.
| Product family | SACE Emax 2 |
|---|---|
| ABB order code | 1SDA070741R1 |
| Product type | Air circuit breaker |
| Frame | E1.2 |
| Short-circuit performance level | B |
| Rated uninterrupted current | 800 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage | 1000 V AC |
| Rated impulse withstand voltage | 12 kV |
| Number of poles | 3 |
| Execution | Fixed |
| Terminal connection | Front |
| Trip unit | Ekip Dip LI |
| Release technology | Solid-state electronic |
| Protection functions | LI |
| Ultimate short-circuit breaking capacity at 400 V AC | 42 kA |
| Ultimate short-circuit breaking capacity at 415 V AC | 42 kA |
| Ultimate short-circuit breaking capacity at 440 V AC | 42 kA |
| Ultimate short-circuit breaking capacity at 690 V AC | 42 kA |
| Rated service short-circuit breaking capacity | 100% of Icu |
| Short-time withstand current, 1 s | 42 kA |
| Short-time withstand current, 3 s | 24 kA |
| Auxiliary contacts | 4 |
| Circuit-breaker position indication | Open / closed |
| Standard | IEC |
| EAN | 8015644745912 |
| ABB product group | Emax2 Air Circuit Breaker |
The ABB 1SDA070741R1 is a SACE Emax 2 E1.2B 800 three-pole fixed air circuit breaker with front terminals and an Ekip Dip LI solid-state electronic trip unit.
The E1.2B 800 configuration has a rated uninterrupted current of 800 A.
The LI configuration provides long-time overload protection and instantaneous short-circuit protection.
The E1.2B 800 provides an ultimate short-circuit breaking capacity of 42 kA at 400 V, 415 V and 440 V AC, with a 42 kA rating also specified at 690 V AC.
The circuit breaker has a rated short-time withstand current of 42 kA for 1 second and 24 kA for 3 seconds.
The 1SDA070741R1 is a fixed Emax 2 air circuit breaker with front terminals.
Yes. This configuration is fitted with four auxiliary contacts and circuit-breaker open/closed position indication.
ABB SACE Emax 2 air circuit breakers are used in industrial, commercial and infrastructure power systems where dependable overload and short-circuit protection, robust switching performance and professional integration into low-voltage switchgear are essential.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.