1SDA070730R1 ABB E1.2N 630 Ekip G Hi-Touch LSIG 3-Pole Fixed Air Circuit Breaker

1SDA070730R1 ABB E1.2N 630 Ekip G Hi-Touch LSIG 3-Pole Fixed Air Circuit Breaker

ABB 1SDA070730R1 is an Emax 2 E1.2N 630 A three-pole fixed air circuit breaker with front terminals and an Ekip G Hi-Touch LSIG solid-state electronic trip unit for advanced generator and low-voltage power-system protection.

SKU: 1SDA070730R1MPN: 1SDA070730R1
Price
List Price £10,191.94 ex VAT
Your Price (ex VAT) Save 25%
£7,643.96 25% OFF
You save £2,547.99 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,643.96
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,643.96

Why Choose the ABB 1SDA070730R1 E1.2N 630 Ekip G Hi-Touch LSIG Air Circuit Breaker?

The ABB 1SDA070730R1 is a SACE Emax 2 E1.2N 630 three-pole fixed air circuit breaker equipped with an advanced Ekip G Hi-Touch LSIG solid-state electronic trip unit. Designed for generator and demanding low-voltage power-distribution applications, this configuration combines a 630 A rated current with comprehensive electronic protection, measurement and monitoring capabilities.

The E1.2N performance level provides an ultimate short-circuit breaking capacity of 66 kA and a short-time withstand current of 50 kA. Its fixed construction and front terminals provide a practical configuration for integration into compatible low-voltage switchboards, while the three-pole arrangement is suited to three-phase distribution systems.

The Ekip G Hi-Touch LSIG release provides generator-oriented functionality together with long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection. The breaker is also supplied with four auxiliary contacts and circuit-breaker open/closed position indication, supporting integration into professional control and monitoring systems.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for generator and distribution protection.
  • 630 A rated current on the compact E1.2 frame.
  • Ekip G Hi-Touch LSIG solid-state trip unit with advanced generator-oriented functionality.
  • 66 kA ultimate short-circuit breaking capacity.
  • 50 kA short-time withstand current.
  • Fixed three-pole construction with front terminals for professional switchboard integration.

Key Features

  • ABB SACE Emax 2 air circuit breaker.
  • E1.2N 630 configuration.
  • 630 A rated current.
  • 690 V rated voltage.
  • Three-pole construction.
  • Fixed execution.
  • Front terminals.
  • Ekip G Hi-Touch solid-state electronic trip unit.
  • LSIG protection: long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection.
  • Supplied with four auxiliary contacts and circuit-breaker open/closed position indication.

Advanced Generator and Power-System Protection

The Ekip G Hi-Touch LSIG electronic trip unit provides comprehensive protection for generator and low-voltage distribution applications. Its LSIG functions cover long-time overload protection, selective short-circuit protection, instantaneous short-circuit protection and earth-fault protection, helping safeguard generators, conductors and connected equipment against a broad range of electrical fault conditions.

Combined with the E1.2N platform, the ABB 1SDA070730R1 provides high fault-interruption performance in a compact fixed configuration. Front terminals simplify integration into compatible switchboards, while auxiliary contacts and open/closed position indication support connection to control, status-monitoring and automation systems.

Typical Applications

  • Generator protection and generator switchboards.
  • Low-voltage main distribution switchboards.
  • Industrial power-distribution systems.
  • Critical and standby power installations.
  • Commercial and infrastructure electrical distribution.
  • OEM switchboards requiring advanced LSIG electronic protection and monitoring.

Technical Specifications

Product family SACE Emax 2
ABB order code 1SDA070730R1
Product type Air circuit breaker
Frame E1.2
Performance level N
Rated current 630 A
Rated voltage 690 V
Number of poles 3
Execution Fixed
Terminal connection Front
Trip unit Ekip G Hi-Touch
Release technology Solid-state electronic
Protection functions LSIG
Ultimate short-circuit breaking capacity 66 kA
Short-time withstand current 50 kA
Auxiliary contacts 4
Circuit-breaker position indication Open / closed
Standard IEC
EAN 8015644745806
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA070730R1?

The ABB 1SDA070730R1 is a SACE Emax 2 E1.2N 630 three-pole fixed air circuit breaker with front terminals and an Ekip G Hi-Touch LSIG solid-state electronic trip unit.

What is the current rating of ABB 1SDA070730R1?

The E1.2N 630 configuration has a 630 A rated current.

What protection functions does the Ekip G Hi-Touch LSIG trip unit provide?

The LSIG configuration provides long-time overload protection, selective short-circuit protection, instantaneous short-circuit protection and earth-fault protection.

Is ABB 1SDA070730R1 suitable for generator protection?

Yes. The Ekip G Hi-Touch trip unit provides advanced generator-oriented protection and monitoring functionality for compatible generator and power-distribution applications.

What is the breaking capacity of the E1.2N 630?

The E1.2N 630 configuration has an ultimate short-circuit breaking capacity of 66 kA.

What is the short-time withstand current of ABB 1SDA070730R1?

The E1.2N configuration has a 50 kA short-time withstand current.

Is ABB 1SDA070730R1 fixed or withdrawable?

The 1SDA070730R1 is a fixed Emax 2 air circuit breaker with front terminals.

Does ABB 1SDA070730R1 include auxiliary contacts?

Yes. This configuration is supplied with four auxiliary contacts and circuit-breaker open/closed position indication.

Trusted by Electrical Professionals Worldwide

ABB SACE Emax 2 air circuit breakers are used in demanding generator, industrial, commercial and infrastructure power systems where dependable fault protection, advanced electronic functionality and robust low-voltage switching performance are essential.