1SDA070728R1 ABB E1.2N 630 Ekip Hi-Touch LSI 3-Pole Fixed Air Circuit Breaker

1SDA070728R1 ABB E1.2N 630 Ekip Hi-Touch LSI 3-Pole Fixed Air Circuit Breaker

ABB 1SDA070728R1 E1.2N 630 is a 630 A three-pole fixed SACE Emax 2 air circuit breaker with front terminals, Ekip Hi-Touch LSI protection, 66 kA ultimate breaking capacity at 380–440 V AC and integrated advanced measurement and power-quality analysis.

SKU: 1SDA070728R1MPN: 1SDA070728R1
Price
List Price £9,028.34 ex VAT
Your Price (ex VAT) Save 25%
£6,771.26 25% OFF
You save £2,257.09 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,771.26
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,771.26

Why Choose the ABB E1.2N 630 Ekip Hi-Touch LSI Air Circuit Breaker?

The ABB E1.2N 630 Ekip Hi-Touch LSI, order code 1SDA070728R1, is a high-performance SACE Emax 2 air circuit breaker designed for protection, control, measurement and monitoring in low-voltage power distribution systems. This configuration combines a 630 A rated uninterrupted current, three-pole construction, fixed installation and front terminals with ABB's advanced Ekip Hi-Touch electronic protection release.

The E1.2N performance level provides an ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC and 50 kA at 500–690 V AC. With a rated operational voltage of up to 690 V AC and rated insulation voltage of 1000 V AC, the breaker is engineered for demanding industrial, commercial and infrastructure distribution systems.

The fitted Ekip Hi-Touch LSI electronic release provides adjustable long-time overload, short-time selective short-circuit and instantaneous short-circuit protection. Integrated Ekip Measuring Pro and Network Analyzer functionality adds advanced electrical measurement and power-quality analysis, making the 1SDA070728R1 particularly suitable for intelligent switchboards requiring comprehensive protection and detailed system visibility.

Key Advantages

  • 630 A rated uninterrupted current for substantial low-voltage distribution circuits.
  • 66 kA ultimate breaking capacity at 380–440 V AC.
  • 50 kA ultimate breaking capacity at 500–690 V AC.
  • Advanced Ekip Hi-Touch LSI electronic protection release.
  • Long-time, short-time and instantaneous protection supports coordinated distribution-system protection.
  • Integrated Ekip Measuring Pro functionality for advanced electrical measurement.
  • Integrated Network Analyzer functionality for power-quality monitoring.
  • 690 V AC rated operational voltage and 1000 V AC insulation voltage.
  • Compact fixed E1.2 construction with front terminals for efficient switchboard integration.

Key Features

  • ABB SACE Emax 2 E1.2N air circuit breaker.
  • Rated uninterrupted current (Iu): 630 A.
  • Three-pole configuration.
  • Fixed (F) execution.
  • Front (F) main terminals.
  • Ekip Hi-Touch LSI solid-state electronic release.
  • LSI protection: long-time, short-time and instantaneous functions.
  • N short-circuit performance level.
  • 66 kA Icu at 380–440 V AC.
  • 50 kA Icu at 500–690 V AC.
  • Integrated Ekip Measuring Pro measurement functionality.
  • Integrated Network Analyzer functionality.
  • Touch-sensitive display interface for protection and measurement configuration.
  • Four auxiliary change-over contacts.
  • Open/closed circuit-breaker position indication.

Advanced LSI Protection and Power Monitoring

The Ekip Hi-Touch LSI release provides three complementary protection functions for coordinated low-voltage distribution. Long-time protection responds to sustained overload conditions, short-time protection provides an adjustable response to short circuits to support selectivity with downstream protective devices, and instantaneous protection provides rapid interruption of severe high-current faults.

Beyond circuit protection, the Ekip Hi-Touch platform incorporates Ekip Measuring Pro and Network Analyzer functionality for detailed monitoring of electrical parameters and power quality. This combination allows the 1SDA070728R1 to operate as both a high-performance protective device and an intelligent monitoring point within modern low-voltage distribution systems.

Typical Applications

  • Low-voltage main and sub-distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process plant electrical systems.
  • Commercial building power distribution.
  • Data centres and critical-power installations.
  • Generator and transformer distribution systems.
  • Applications requiring selective LSI circuit protection.
  • Smart switchboards requiring integrated electrical measurement.
  • Power distribution systems requiring integrated power-quality analysis.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA070728R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Rated uninterrupted current (Iu) 630 A
Rated operational voltage (Ue) up to 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50/60 Hz
Number of poles 3
Short-circuit performance level N
Icu at 380 V AC 66 kA
Icu at 400/415 V AC 66 kA
Icu at 440 V AC 66 kA
Icu at 500/525 V AC 50 kA
Icu at 690 V AC 50 kA
Protection release Ekip Hi-Touch LSI
Release type Electronic
Overload protection adjustment 252–630 A
Short-time delayed short-circuit adjustment 378–6300 A
Instantaneous short-circuit adjustment 945–9450 A
Integrated earth-fault protection No
Measurement Ekip Measuring Pro
Power-quality analysis Network Analyzer
Execution Fixed
Terminal connection Front
Main-circuit connection Bolted
Auxiliary change-over contacts 4
Motor drive Optional
Standard IEC 60947-2
Net weight 14 kg

Frequently Asked Questions

What is the ABB 1SDA070728R1?

The ABB 1SDA070728R1 is a 630 A three-pole SACE Emax 2 E1.2N air circuit breaker with fixed construction, front terminals and an advanced Ekip Hi-Touch LSI electronic protection release.

What protection functions does the Ekip Hi-Touch LSI release provide?

The LSI release provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection, with adjustable settings for coordinated low-voltage power distribution.

What is the breaking capacity of the ABB E1.2N 630?

The E1.2N 630 provides an ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC and 50 kA at 500–690 V AC.

Is the ABB 1SDA070728R1 fixed or withdrawable?

The 1SDA070728R1 is a fixed three-pole air circuit breaker equipped with front main terminals for permanent installation in a compatible low-voltage switchboard.

Does the ABB 1SDA070728R1 provide measurement and power-quality monitoring?

Yes. Its Ekip Hi-Touch configuration incorporates Ekip Measuring Pro and Network Analyzer functionality, providing advanced electrical measurement and power-quality monitoring alongside LSI circuit protection.

Trusted for Intelligent Power Distribution

ABB SACE Emax 2 air circuit breakers combine high-performance fault interruption, selective electronic protection, advanced measurement and digital functionality in a compact platform engineered for dependable industrial, commercial and critical-power distribution systems.