ABB 1SDA070725R1 E1.2N 630 is a 630 A three-pole fixed SACE Emax 2 air circuit breaker with front terminals and an Ekip Touch LSI electronic trip unit for overload, selective short-circuit and instantaneous protection.

SKU: 1SDA070725R1MPN: 1SDA070725R1
Price
List Price £5,557.42 ex VAT
Your Price (ex VAT) Save 25%
£4,168.07 25% OFF
You save £1,389.36 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,168.07
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,168.07

Why Choose the ABB E1.2N 630 Ekip Touch LSI 3P F F Air Circuit Breaker?

The ABB E1.2N 630 Ekip Touch LSI 3P F F, order code 1SDA070725R1, is a 630 A three-pole fixed air circuit breaker from the ABB SACE Emax 2 range. Designed for low-voltage AC power distribution, it combines the compact E1.2 frame with an advanced Ekip Touch LSI electronic trip unit for overload, selective short-circuit and instantaneous short-circuit protection.

The E1.2N performance level provides a rated ultimate short-circuit breaking capacity of 66 kA at common low-voltage distribution levels. Its Ekip Touch LSI release incorporates long-time (L), short-time selective (S) and instantaneous (I) protection functions, supporting coordinated protection strategies where discrimination between upstream and downstream devices is important.

Rated at 630 A and 690 V AC, the 1SDA070725R1 uses a fixed three-pole configuration with front terminals. The breaker is supplied complete with its protection unit, four auxiliary changeover contacts and open/closed position indication, providing a capable solution for industrial, commercial and infrastructure switchboards.

Key Advantages

  • Genuine ABB SACE Emax 2 air circuit breaker.
  • 630 A rated current for substantial low-voltage distribution loads.
  • 66 kA short-circuit performance class for demanding installations.
  • Advanced Ekip Touch LSI electronic trip unit.
  • Long-time, short-time selective and instantaneous protection.
  • Short-time protection supports improved selectivity with downstream protective devices.
  • Three-pole fixed construction with front terminals.
  • 690 V AC rated operational voltage.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 630 A rated uninterrupted current.
  • Ekip Touch LSI electronic release.
  • Long-time (L) overload protection.
  • Short-time selective (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Three-pole construction.
  • Fixed (F) execution.
  • Front (F) terminals.
  • 690 V AC rated operational voltage.
  • 66 kA E1.2N breaking-performance class.
  • Four auxiliary changeover contacts.
  • Open/closed circuit-breaker position indication.
  • Optional motor drive capability.
  • IP30 degree of protection.

Advanced LSI Protection for Selective Distribution

The Ekip Touch LSI trip unit provides three complementary protection functions. Long-time protection responds to sustained overload currents, short-time protection allows controlled delayed operation during short-circuit conditions to support selectivity, and instantaneous protection provides rapid interruption when severe fault currents occur.

This combination makes the 1SDA070725R1 particularly useful in distribution systems where coordination between protective devices is required. Together with the 630 A rating, E1.2N fault performance and compact fixed construction, the breaker provides a flexible solution for protecting main distribution and feeder circuits while supporting continuity of supply in properly coordinated systems.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Commercial building electrical distribution.
  • Main incomer and feeder protection.
  • Selective and coordinated distribution networks.
  • Manufacturing and process plant switchgear.
  • Motor control centres and power distribution panels.
  • Infrastructure and utility electrical installations.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA070725R1
Product type Air circuit breaker
Frame E1.2
Performance level N
Rated uninterrupted current (Iu) 630 A
Number of poles 3
Current type AC
Trip unit Ekip Touch LSI
Trip-unit technology Electronic / solid-state
Protection functions Long-time (L), short-time selective (S), instantaneous (I)
Overload release current setting From 252 A
Short-time delayed short-circuit release setting From 378 A
Instantaneous short-circuit release setting From 945 A
Integrated earth-fault protection No
Installation version Fixed
Terminal configuration Front
Main-circuit connection Bolt connection
Rated operational voltage (Ue) 690 V AC
Short-circuit performance class 66 kA
Auxiliary changeover contacts 4
Open/closed position indication Yes
Motor drive Optional
Degree of protection IP30
EAN 8015644745752
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA070725R1?

The ABB 1SDA070725R1 is an E1.2N 630 A three-pole fixed SACE Emax 2 air circuit breaker with front terminals and an Ekip Touch LSI electronic protection unit.

What protection functions does the Ekip Touch LSI provide?

The Ekip Touch LSI provides long-time (L) overload, short-time selective (S) short-circuit and instantaneous (I) short-circuit protection.

What is the rated current of the ABB E1.2N 1SDA070725R1?

The circuit breaker has a rated uninterrupted current of 630 A.

What is the rated voltage of the ABB 1SDA070725R1?

The breaker has a rated operational voltage of 690 V AC and belongs to ABB's 66 kA E1.2N performance class.

What is the difference between Ekip Touch LI and Ekip Touch LSI?

An LI release provides long-time and instantaneous protection, while the LSI release in this breaker adds short-time selective protection, allowing additional coordination with downstream protective devices.

Trusted ABB Power Distribution Technology

ABB SACE Emax 2 air circuit breakers combine compact construction, high fault-interruption performance and advanced Ekip electronic protection to provide selective and dependable protection for modern low-voltage power distribution systems.