ABB 1SDA070718R1 E1.2C is a 630 A three-pole fixed Emax 2 air circuit breaker with an Ekip Hi-Touch LSI electronic trip unit, 690 V AC operational voltage and 50 kA breaking capacity at 440 V AC for advanced low-voltage circuit protection.
£6,214.49
The ABB E1.2C 630 Ekip Hi-Touch LSI 3P F F (1SDA070718R1) is an advanced three-pole air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage electrical distribution systems. As part of the ABB SACE Emax 2 E1.2 range, it combines a compact fixed-frame design with the sophisticated Ekip Hi-Touch electronic trip unit for precise protection and power distribution management.
The integrated Ekip Hi-Touch LSI electronic release provides long-time, short-time and instantaneous overcurrent protection. This combination protects against overload and short-circuit conditions while offering the adjustable protection functionality required for effective coordination and selectivity in sophisticated industrial and commercial distribution networks.
With a rated uninterrupted current of 630 A, a rated operational voltage up to 690 V AC and a three-pole fixed configuration, the E1.2C 630 provides substantial performance from a compact E1.2 frame. The C performance level delivers a rated ultimate short-circuit breaking capacity of 50 kA at 440 V AC, while front terminals simplify integration into compatible low-voltage switchboards.
Air circuit breakers such as the ABB SACE Emax 2 provide switching, isolation and electronic protection for important low-voltage distribution circuits. The Ekip Hi-Touch trip unit continuously evaluates electrical conditions and operates the breaker according to configured protection thresholds, helping protect cables, busbars and connected equipment against damaging overload and short-circuit conditions.
The LSI protection configuration combines long-time overload protection with short-time and instantaneous short-circuit protection. Together with the E1.2C breaker’s 50 kA breaking capacity at 440 V AC, this provides a powerful protection platform for applications requiring dependable fault interruption, protection coordination and continuity of electrical service.
| Series | SACE Emax 2 |
|---|---|
| Order code | 1SDA070718R1 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker |
| Frame | E1.2 |
| Performance level | C |
| Rated current (In) | 630 A |
| Rated uninterrupted current (Iu) | 630 A |
| Number of poles | 3 |
| Current type | AC |
| Trip unit | Ekip Hi-Touch LSI |
| Release type | Electronic |
| Protection functions | L, S, I |
| Rated operational voltage (Ue) | up to 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 400–440 V AC | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500–690 V AC | 42 kA |
| Rated service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw), 1 s | 42 kA |
| Rated short-time withstand current (Icw), 3 s | 24 kA |
| Mounting type | Fixed |
| Terminal configuration | Front terminals |
| Main terminal type | Bolt connection |
| Main circuit tightening torque | 45 N·m |
| Power loss | 31 W |
| Mechanical durability | 20,000 operating cycles |
| Electrical durability | 8,000 operating cycles |
| Protection rating | IP30 |
| Standard | IEC 60947-2 |
| EAN | 8015644745684 |
The ABB 1SDA070718R1 is a 630 A Emax 2 air circuit breaker designed for switching, isolation and electronic overcurrent protection in industrial, commercial and infrastructure low-voltage distribution systems.
The Ekip Hi-Touch LSI electronic trip unit provides long-time overload protection (L), short-time short-circuit protection (S) and instantaneous short-circuit protection (I).
The E1.2C 630 has a rated ultimate short-circuit breaking capacity of 50 kA at 400–440 V AC and 42 kA at 500–690 V AC.
The ABB 1SDA070718R1 has a rated operational voltage of up to 690 V AC, with a rated insulation voltage of 1000 V AC.
The 1SDA070718R1 is a fixed three-pole air circuit breaker with front terminals, designed for permanent installation within a compatible low-voltage switchboard.
ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, high fault-interruption performance and compact switchgear design to provide dependable control and protection for demanding industrial, commercial and infrastructure power distribution systems.