1SDA070712R1 ABB E1.2C 630 Ekip Dip LSI 3P Fixed Air Circuit Breaker

1SDA070712R1 ABB E1.2C 630 Ekip Dip LSI 3P Fixed Air Circuit Breaker

ABB 1SDA070712R1 is an Emax 2 E1.2C 630 A three-pole fixed air circuit breaker with front terminals and an Ekip Dip LSI electronic trip unit for low-voltage power distribution protection.

SKU: 1SDA070712R1MPN: 1SDA070712R1
Price
List Price £4,855.21 ex VAT
Your Price (ex VAT) Save 25%
£3,641.41 25% OFF
You save £1,213.80 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,641.41
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,641.41

Why Choose the ABB E1.2C 630 Ekip Dip LSI 3P Fixed Air Circuit Breaker?

The ABB 1SDA070712R1 is a high-performance Emax 2 E1.2C air circuit breaker (ACB) designed for reliable protection and switching in low-voltage power distribution systems. Rated at 630 A, this three-pole breaker incorporates an Ekip Dip LSI electronic trip unit providing long-time overload, short-time short-circuit and instantaneous short-circuit protection.

As part of the advanced ABB Emax 2 range, the E1.2C combines compact construction with strong short-circuit performance for industrial, commercial and infrastructure switchboards. Its electronic protection system supports effective selectivity and dependable protection of cables, busbars and connected electrical equipment.

This configuration is a three-pole fixed circuit breaker with front terminals. The E1.2C performance class provides an ultimate short-circuit breaking capacity of 50 kA at 440 V AC and a short-time withstand current of 42 kA for 1 second, with a rated operational voltage up to 690 V AC.

Key Advantages

  • Compact ABB Emax 2 E1.2C air circuit breaker for low-voltage power distribution.
  • 630 A rated current for industrial and commercial electrical systems.
  • Ekip Dip LSI electronic trip unit for comprehensive overcurrent protection.
  • 50 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 42 kA short-time withstand current for 1 second.
  • Fixed three-pole construction with front terminals for switchboard installation.

Key Features

  • ABB Emax 2 E1.2C air circuit breaker.
  • 630 A rated uninterrupted current.
  • 3-pole configuration.
  • Fixed circuit-breaker version.
  • Front terminal connection arrangement.
  • Ekip Dip LSI electronic protection trip unit.
  • Long-time overload (L) protection.
  • Short-time short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • Rated operational voltage up to 690 V AC.

Reliable LSI Protection for Power Distribution

Air circuit breakers protect low-voltage distribution systems against damaging overcurrent conditions while also providing switching and isolation functions. The ABB Emax 2 platform combines high breaking performance with electronic protection technology, helping provide dependable protection and selectivity in modern electrical distribution networks.

The Ekip Dip LSI trip unit fitted to this E1.2C configuration provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. This combination makes the breaker suitable for distribution systems requiring coordinated protection against both sustained overloads and high-level fault currents.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Commercial building electrical distribution.
  • Manufacturing and process facilities.
  • Infrastructure and utility installations.
  • OEM switchboards and electrical distribution assemblies.

Technical Specifications

Series Emax 2
Order code 1SDA070712R1
Product type Air circuit breaker
Frame E1.2C
Short-circuit performance level C
Rated uninterrupted current (Iu) 630 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 3
Installation Fixed
Terminal arrangement Front terminals
Terminal type Bolted
Trip unit Ekip Dip LSI
Release type Electronic
Protection functions L (overload), S (short-time short circuit), I (instantaneous short circuit)
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 50 kA
Service short-circuit breaking capacity (Ics) at 440 V AC 50 kA
Short-time withstand current (Icw), 1 s 42 kA
Short-time withstand current (Icw), 3 s 24 kA
Electrical durability 8000 cycles
Mechanical durability 20000 cycles
Dimensions (H × W × D) 296 × 210 × 183 mm
Weight 14 kg
Standard IEC
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA070712R1?

The ABB 1SDA070712R1 is an Emax 2 E1.2C 630 A three-pole fixed air circuit breaker with front terminals and an Ekip Dip LSI electronic trip unit.

What protection functions does the Ekip Dip LSI trip unit provide?

The Ekip Dip LSI provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E1.2C 630?

The E1.2C configuration has an ultimate short-circuit breaking capacity of 50 kA at 440 V AC.

Is the ABB 1SDA070712R1 fixed or withdrawable?

The 1SDA070712R1 is a fixed three-pole air circuit breaker with front terminals.

What is the rated operational voltage of the ABB 1SDA070712R1?

The circuit breaker has a rated operational voltage of up to 690 V AC, making it suitable for a wide range of low-voltage industrial power distribution systems.

Trusted by Power Distribution Professionals Worldwide

ABB Emax 2 air circuit breakers are engineered for dependable switching and protection in low-voltage power distribution systems, combining compact construction, high short-circuit performance and advanced electronic protection.