1SDA070695R1 ABB E1.2N 250 Ekip Touch LSI 3P F F Air Circuit Breaker

1SDA070695R1 ABB E1.2N 250 Ekip Touch LSI 3P F F Air Circuit Breaker

ABB 1SDA070695R1 E1.2N 250 is a 250 A three-pole fixed SACE Emax 2 air circuit breaker with front terminals and Ekip Touch LSI electronic overload, selective short-circuit and instantaneous protection.

SKU: 1SDA070695R1MPN: 1SDA070695R1
Price
List Price £5,878.42 ex VAT
Your Price (ex VAT) Save 25%
£4,408.82 25% OFF
You save £1,469.61 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,408.82
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,408.82

Why Choose the ABB E1.2N 250 Ekip Touch LSI 3P F F Air Circuit Breaker?

The ABB E1.2N 250 Ekip Touch LSI 3P F F, order code 1SDA070695R1, is a 250 A three-pole fixed air circuit breaker from the ABB SACE Emax 2 range. Designed for low-voltage power distribution, it combines the compact E1.2 frame with an advanced Ekip Touch LSI electronic trip unit for adjustable overload, selective short-circuit and instantaneous short-circuit protection.

The E1.2N configuration provides an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC. Its Ekip Touch LSI release incorporates long-time (L), short-time selective (S) and instantaneous (I) protection, providing greater protection flexibility than an LI-only release and making the breaker particularly suitable for coordinated power distribution systems.

Rated at 250 A with an operational voltage up to 690 V AC, this model uses a fixed installation with front terminals. Its compact construction, high fault-interruption capability and configurable electronic protection make it a strong choice for incomers, feeders and distribution circuits in industrial, commercial and infrastructure switchboards.

Key Advantages

  • Genuine ABB SACE Emax 2 air circuit breaker.
  • 250 A rated current for low-voltage power distribution.
  • 66 kA ultimate breaking capacity at 400–440 V AC.
  • Advanced Ekip Touch LSI electronic trip unit.
  • Long-time, short-time selective and instantaneous protection.
  • Adjustable protection functions support improved system selectivity and coordination.
  • Three-pole fixed configuration with front terminals.
  • Rated for operation up to 690 V AC.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 250 A rated uninterrupted current.
  • Ekip Touch LSI electronic release.
  • Long-time (L) overload protection.
  • Short-time selective (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Three-pole construction.
  • Fixed (F) execution.
  • Front (F) terminals.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 50/60 Hz operating frequency.
  • 66 kA Icu at 400–440 V AC.
  • 50 kA Icu at 500–690 V AC.
  • 50 kA short-time withstand current for 1 s.
  • Designed to IEC 60947-2.

Advanced LSI Protection for Selective Power Distribution

The Ekip Touch LSI trip unit provides three key protection functions. Long-time protection responds to sustained overloads, short-time selective protection allows delayed response to short-circuit currents to support coordination with downstream protective devices, and instantaneous protection provides rapid interruption of severe fault currents.

Combined with the E1.2N breaker's 66 kA ultimate breaking capacity at 400–440 V AC and 50 kA short-time withstand capability for 1 s, the LSI release makes the 1SDA070695R1 particularly suitable for distribution systems where both high fault performance and selective protection are important. The fixed mounting and front terminals also provide a straightforward arrangement for permanent switchboard installation.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Commercial building electrical distribution.
  • Main incomer and feeder protection.
  • Selective and coordinated distribution networks.
  • Manufacturing and process plant switchgear.
  • Motor control centres and power distribution panels.
  • Infrastructure and utility low-voltage installations.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA070695R1
Product type Air circuit breaker
Frame E1.2
Short-circuit performance level N
Rated uninterrupted current (Iu) 250 A
Number of poles 3
Current type AC
Release Ekip Touch LSI
Release type Electronic
Protection functions Long-time (L), short-time selective (S), instantaneous (I)
Long-time protection setting Adjustable from 0.4–1 × In
Instantaneous protection setting Adjustable from 1.5–15 × In
Installation version Fixed
Terminal connection Front
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50/60 Hz
Rated ultimate short-circuit breaking capacity (Icu) at 400–440 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–690 V AC 50 kA
Rated service short-circuit breaking capacity (Ics) at 400–690 V AC 50 kA
Ics as percentage of Icu 100%
Rated short-time withstand current (Icw) 50 kA for 1 s; 30 kA for 3 s
Standard IEC 60947-2
EAN 8015644745455
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA070695R1?

The ABB 1SDA070695R1 is an E1.2N 250 A three-pole fixed SACE Emax 2 air circuit breaker with front terminals and an Ekip Touch LSI electronic trip unit.

What protection functions does the Ekip Touch LSI provide?

The Ekip Touch LSI provides long-time (L) overload, short-time selective (S) short-circuit and instantaneous (I) short-circuit protection.

What is the breaking capacity of the ABB E1.2N 250?

The E1.2N has an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC.

What is the rated voltage of the ABB 1SDA070695R1?

The breaker has a rated operational voltage of 690 V AC and a rated insulation voltage of 1000 V AC.

How is the ABB E1.2N 250 1SDA070695R1 installed?

This model is a fixed three-pole air circuit breaker with front terminals, designed for permanent installation within a compatible low-voltage switchboard.

Trusted ABB Power Distribution Technology

ABB SACE Emax 2 air circuit breakers combine high-performance fault interruption with advanced Ekip electronic protection, providing flexible, selective and dependable protection for modern low-voltage power distribution systems.