ABB 1SDA070157R1 XT3N 250 is a 63 A three-pole fixed moulded case circuit breaker with front terminals, a TMD thermomagnetic trip unit, 630 A magnetic protection setting and 36 kA breaking capacity at 415 V AC for low-voltage circuit protection.

SKU: 1SDA070157R1MPN: 1SDA070157R1
Price
List Price £780.71 ex VAT
Your Price (ex VAT) Save 25%
£585.53 25% OFF
You save £195.18 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £585.53
Trade pricing is personalised to your account

Manufacturer Lead Time

£585.53

Why Choose the ABB XT3N 250 TMD 63-630 3p F F 50°C?

The ABB XT3N 250 TMD 63-630 3p F F 50°C, order code 1SDA070157R1, is a three-pole moulded case circuit breaker (MCCB) designed for dependable protection and switching in low-voltage electrical distribution systems. Part of the ABB SACE Tmax XT3 range, it combines a compact 250 A frame with a 63 A TMD thermomagnetic trip unit.

The integrated TMD thermomagnetic release combines thermal overload protection with magnetic short-circuit protection. This version has a rated current of 63 A and a magnetic protection setting of 630 A, providing straightforward and reliable protection without the need for an electronic trip unit.

Designed with a 50 °C reference temperature, the 1SDA070157R1 features a three-pole fixed configuration with front terminals and a rated voltage of 690 V. Its N interruption-performance class provides an ultimate short-circuit breaking capacity of 36 kA at 415 V AC, making it suitable for a broad range of industrial, commercial and OEM distribution applications.

Key Advantages

  • Compact ABB Tmax XT3N moulded case circuit breaker for low-voltage distribution.
  • 63 A rated current within the XT3 250 A frame.
  • TMD thermomagnetic release provides overload and short-circuit protection.
  • 630 A magnetic protection setting for rapid operation under high fault-current conditions.
  • 36 kA ultimate breaking capacity at 415 V AC.
  • Fixed three-pole construction with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT3N 250 MCCB.
  • 63 A rated current.
  • 250 A frame size.
  • 3-pole configuration.
  • TMD thermomagnetic trip unit.
  • Thermal protection for sustained overload conditions.
  • Magnetic protection for short-circuit conditions.
  • 630 A magnetic protection setting.
  • N breaking-performance class.
  • Rated voltage of 690 V.
  • 50 °C reference temperature for the thermomagnetic release.
  • Fixed mounting with front terminals.

Reliable Thermomagnetic Protection for Low-Voltage Distribution

Thermomagnetic moulded case circuit breakers combine two proven protection principles within a single device. The thermal element responds to sustained overload conditions, while the magnetic element provides rapid operation when a high short-circuit current occurs. This provides dependable circuit protection through a straightforward mechanical and electromagnetic protection system.

The ABB XT3N 250 1SDA070157R1 combines TMD protection with the robust Tmax XT3 platform. Its 63 A rated current, 630 A magnetic setting, three-pole construction and 36 kA breaking capacity at 415 V AC make it well suited to feeders, machinery supplies and distribution circuits requiring reliable protection in a compact MCCB format.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Commercial building switchboards and distribution panels.
  • Three-phase feeder and branch-circuit protection.
  • Machinery and automation power distribution.
  • Manufacturing and process plant electrical systems.
  • Electrical installations requiring thermomagnetic overload and short-circuit protection.
  • OEM switchgear and electrical panel assemblies.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Order code 1SDA070157R1
Alternate catalogue number XT3N53063AFF000XXX
UPC / EAN 8015644709709
Product type Moulded case circuit breaker
Frame size XT3
Frame rating 250 A
Performance level N
Rated current (In) 63 A
Number of poles 3
Trip unit TMD thermomagnetic release
Magnetic protection setting (I3) 630 A
Rated voltage 690 V
Ultimate breaking capacity (Icu) at 415 V AC 36 kA
Reference temperature 50 °C
Mounting type Fixed
Terminal type Front terminals
Standard / certification IEC

Frequently Asked Questions

What is the ABB 1SDA070157R1 used for?

The ABB 1SDA070157R1 is a 63 A three-pole moulded case circuit breaker designed to provide overload and short-circuit protection in low-voltage electrical distribution systems.

What trip unit is fitted to the ABB XT3N 250 1SDA070157R1?

The circuit breaker is fitted with an ABB TMD thermomagnetic release, combining thermal overload protection with magnetic short-circuit protection.

What does 63-630 mean on the XT3N 250 TMD?

The designation identifies a 63 A rated current together with a 630 A magnetic protection setting for the TMD thermomagnetic trip unit.

What is the breaking capacity of the ABB XT3N 250 at 415 V?

This XT3N configuration has an ultimate short-circuit breaking capacity of 36 kA at 415 V AC.

How is the ABB XT3N 250 TMD 1SDA070157R1 installed?

This model is a fixed three-pole circuit breaker with front terminals, designed for permanent installation in compatible low-voltage switchboards, distribution panels and electrical assemblies.

Trusted ABB Low-Voltage Circuit Protection

ABB SACE Tmax XT moulded case circuit breakers combine compact construction, proven thermomagnetic protection and robust short-circuit performance for industrial, commercial and OEM low-voltage power distribution systems.