1SDA069640R1 ABB XT4L 250 Ekip E-LSIG 250A 4-Pole Circuit Breaker

1SDA069640R1 ABB XT4L 250 Ekip E-LSIG 250A 4-Pole Circuit Breaker

ABB 1SDA069640R1 XT4L 250 is a fixed four-pole 250 A moulded case circuit breaker with front terminals and an Ekip E-LSIG electronic trip unit providing comprehensive LSIG protection for demanding low-voltage power distribution systems.

SKU: 1SDA069640R1Alt SKU: XT4L 250MPN: 1SDA069640R1
Price
List Price £2,633.99 ex VAT
Your Price (ex VAT) Save 25%
£1,975.49 25% OFF
You save £658.50 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,975.49
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,975.49

Why Choose the ABB 1SDA069640R1 XT4L 250 Ekip E-LSIG 250A 4-Pole Circuit Breaker?

The ABB 1SDA069640R1, designated XT4L 250 Ekip E-LSIG In=250A 4p F F, is a fixed four-pole moulded case circuit breaker (MCCB) from the ABB SACE Tmax XT range. Built on the XT4L 250 frame and rated at 250 A, it is designed for protection and switching in demanding low-voltage power distribution systems.

The integrated Ekip E-LSIG electronic trip unit provides comprehensive LSIG protection, covering long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault conditions. Electronic protection enables accurate fault detection and adjustable protection characteristics for effective coordination within industrial and commercial distribution networks.

This model has a four-pole configuration and is supplied for fixed installation with front terminals. The XT4L performance level is intended for applications requiring high short-circuit interruption capability, while the Ekip E-LSIG release has a short-circuit setting range extending from 1–10 × In.

Key Advantages

  • Genuine ABB SACE Tmax XT4L 250 moulded case circuit breaker.
  • 250 A rated current for substantial low-voltage distribution loads.
  • Four-pole configuration suitable for three-phase systems requiring neutral switching.
  • Advanced Ekip E-LSIG electronic protection.
  • Comprehensive LSIG protection against overload, short-circuit and earth-fault conditions.
  • High-performance XT4L breaking-capacity class for demanding installations.
  • Fixed mounting with front terminals supports conventional switchboard integration.

Key Features

  • ABB SACE Tmax XT4L 250 circuit breaker.
  • 250 A rated current (In).
  • 4-pole configuration.
  • Ekip E-LSIG electronic trip unit.
  • L – long-time overload protection.
  • S – short-time short-circuit protection.
  • I – instantaneous short-circuit protection.
  • G – earth-fault protection.
  • Short-circuit setting range of 1–10 × In.
  • Fixed circuit breaker installation with front terminals.

Advanced LSIG Protection for High-Performance Distribution

The Ekip E-LSIG electronic release combines four essential protection functions within the circuit breaker. Long-time protection responds to sustained overloads, short-time and instantaneous functions protect against short-circuit faults, and ground-fault protection detects damaging current paths to earth. Together, these functions provide comprehensive protection for cables, switchgear and connected electrical equipment.

The XT4L performance class is designed for distribution systems with elevated prospective fault currents. Combined with the 250 A rating, four-pole architecture and configurable electronic protection, the 1SDA069640R1 provides a compact solution for demanding industrial and commercial low-voltage switchboards.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Commercial building power distribution systems.
  • Four-pole three-phase distribution circuits.
  • Manufacturing and process plant electrical systems.
  • Infrastructure and utility distribution panels.
  • Main and sub-distribution circuits requiring electronic LSIG protection.
  • Installations with elevated prospective short-circuit currents.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Frame / size XT4L 250
ABB order code 1SDA069640R1
Product type Moulded case circuit breaker
Application Low-voltage power distribution
Rated current (In) 250 A
Frame rated current 250 A
Number of poles 4
Trip unit Ekip E-LSIG electronic release
Protection functions LSIG
Short-circuit setting range 1–10 × In
Installation Fixed
Terminal configuration Front terminals
Rated operational voltage up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Performance class XT4L
Selectivity category A
Standard IEC 60947-2
Electrical durability 8000 operations
Electrical operating rate 120 cycles/hour

Frequently Asked Questions

What is the ABB 1SDA069640R1?

The ABB 1SDA069640R1 is an XT4L 250 four-pole moulded case circuit breaker rated at 250 A and equipped with an Ekip E-LSIG electronic trip unit.

What protection functions does the Ekip E-LSIG trip unit provide?

The Ekip E-LSIG provides LSIG protection: long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.

What is the rated current of the ABB XT4L 250 1SDA069640R1?

The circuit breaker is rated at 250 A and uses the XT4L 250 frame.

Is the ABB 1SDA069640R1 a four-pole circuit breaker?

Yes. The 1SDA069640R1 has a four-pole configuration, making it suitable for compatible three-phase distribution systems where switching and protection of four conductors is required.

How is the ABB 1SDA069640R1 installed?

The 1SDA069640R1 is a fixed circuit breaker with front terminals, designed for integration into compatible low-voltage switchboards and distribution panels.

Trusted ABB Low-Voltage Protection Technology

ABB SACE Tmax XT moulded case circuit breakers combine compact construction, high short-circuit performance and advanced electronic protection, making the XT4L 250 Ekip E-LSIG a robust solution for demanding industrial and commercial low-voltage power distribution systems.