ABB XT4H 160 4 pole High MCCB Electronic trip unit I Ii=100A

ABB XT4H 160 4 pole High MCCB Electronic trip unit I Ii=100A

ABB 1SDA068538R1 SACE Tmax XT4H 160 moulded case circuit breaker with Ekip Dip I electronic release, 80 A rated current, four-pole fixed configuration, front terminals and 70 kA breaking capacity at 415 V AC.

SKU: 1SDA068538R1Alt SKU: XT4H 160 Ekip I In=100A 4p F FMPN: 1SDA068538R1
Price
List Price £1,479.58 ex VAT
Your Price (ex VAT) Save 25%
£1,109.69 25% OFF
You save £369.90 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,109.69
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,109.69

Why Choose the ABB 1SDA068538R1 SACE Tmax XT4H MCCB?

The ABB 1SDA068538R1 is a reliable SACE Tmax XT4H moulded case circuit breaker (MCCB) designed for dependable short-circuit protection in low voltage electrical distribution systems. As part of ABB’s trusted Tmax XT circuit breaker range, this four-pole fixed breaker combines compact construction, high breaking performance and robust electronic protection for industrial and commercial power distribution applications.

This MCCB is fitted with an Ekip Dip I solid-state electronic release, providing instantaneous short-circuit protection for circuits where fast fault interruption is required. Its fixed configuration with front terminals allows straightforward integration into switchboards, distribution boards, electrical panels and low voltage power assemblies.

With a rated current of 80 A, a 690 V AC rated operational voltage and a high breaking capacity of 70 kA at 415 V AC, the ABB 1SDA068538R1 is well suited to installations requiring compact, reliable and high-performance circuit protection.

Key Advantages

  • High-performance ABB SACE Tmax XT4H moulded case circuit breaker.
  • 80 A rated current for protected low voltage distribution circuits.
  • Four-pole fixed configuration for three-phase and neutral applications.
  • Ekip Dip I electronic trip unit for instantaneous short-circuit protection.
  • 70 kA breaking capacity at 415 V AC for strong fault interruption performance.
  • Compact XT4 frame design for efficient switchboard installation.

Key Features

  • ABB SACE Tmax XT series.
  • XT4H 160 frame moulded case circuit breaker.
  • 80 A rated current.
  • Four-pole fixed breaker.
  • Ekip Dip I solid-state electronic release.
  • 690 V AC rated operational voltage.
  • Front terminal connection.
  • Designed for industrial and commercial low voltage power distribution.

Instantaneous Protection for Low Voltage Distribution

Moulded case circuit breakers such as the ABB 1SDA068538R1 are used to disconnect electrical circuits during fault conditions, helping protect cables, switchgear, machinery and downstream equipment from damage caused by short circuits. The XT4H frame provides strong short-circuit performance in a compact breaker format.

The Ekip Dip I electronic release is designed for applications requiring instantaneous protection. Combined with ABB’s Tmax XT platform, this MCCB supports dependable fault interruption, efficient panel design and reliable operation across modern low voltage distribution systems.

Typical Applications

  • Industrial low voltage switchboards.
  • Commercial power distribution panels.
  • Electrical control panels and feeder circuits.
  • Building services electrical installations.
  • Manufacturing and process control systems.
  • Transformer, generator and distribution circuit protection.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Trip Unit I
Current 100 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 70 kA
Manufacturer ABB
Series SACE Tmax XT
Model XT4H 160 Ekip I In=80A 4p F F
SKU 1SDA068538R1
Product type Moulded case circuit breaker
Frame size XT4
Sub-type XT4H
Rated current 80 A
Rated uninterrupted current 160 A
Number of poles 4
Trip unit Ekip Dip I
Release type Electronic / solid-state
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Rated frequency 50 / 60 Hz
Breaking capacity 70 kA at 415 V AC
Terminal type Front terminals
Mounting version Fixed
Standard IEC 60947-2
Dimensions (H × W × D) approx. 160 × 140 × 82.5 mm
Weight approx. 3.5 kg
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA068538R1 used for?

The ABB 1SDA068538R1 is used to protect low voltage electrical circuits against short-circuit faults in industrial and commercial power distribution systems.

What current rating does this MCCB have?

This ABB XT4H MCCB has a rated current of 80 A.

How many poles does the ABB 1SDA068538R1 have?

The ABB 1SDA068538R1 is a four-pole fixed moulded case circuit breaker.

What type of trip unit is fitted?

This breaker is fitted with an Ekip Dip I electronic trip unit, providing instantaneous short-circuit protection.

What is the breaking capacity at 415 V AC?

The ABB 1SDA068538R1 has a rated ultimate short-circuit breaking capacity of 70 kA at 415 V AC.

Trusted by Electrical Professionals Worldwide