ABB XT4S 250 4 pole Standard MCCB Electronic trip unit LSI Ii=250A

ABB XT4S 250 4 pole Standard MCCB Electronic trip unit LSI Ii=250A

ABB 1SDA068505R1 SACE Tmax XT4S moulded case circuit breaker with Ekip C Dip LSI electronic trip unit, 250 A rated current, four-pole fixed configuration and front terminals for low-voltage power distribution.

SKU: 1SDA068505R1Alt SKU: XT4S 250 Ekip LSI In=250A 4p F FMPN: 1SDA068505R1
Price
List Price £2,596.83 ex VAT
Your Price (ex VAT) Save 25%
£1,947.62 25% OFF
You save £649.21 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,947.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,947.62

Why Choose the ABB 1SDA068505R1 SACE Tmax XT4S MCCB?

The ABB 1SDA068505R1 is a premium SACE Tmax XT4S moulded case circuit breaker (MCCB) engineered to provide dependable protection for low-voltage power distribution systems. As part of ABB's advanced SACE Tmax XT range, it delivers high breaking performance, intelligent electronic protection and exceptional reliability for industrial, commercial and OEM electrical installations.

This model incorporates an Ekip C Dip LSI electronic trip unit, providing adjustable long-time, short-time and instantaneous protection functions. Its fixed four-pole construction with front terminals enables simple installation within switchboards, motor control centres and distribution panels while delivering accurate protection for demanding electrical applications.

With a 250 A rated current, XT4S 250 frame and 690 V AC rated operational voltage, the ABB 1SDA068505R1 is ideally suited for protecting incoming supplies, feeders and critical industrial distribution systems where dependable circuit interruption is essential.

Key Advantages

  • High-performance ABB SACE Tmax XT4S moulded case circuit breaker.
  • 250 A rated current for industrial and commercial power distribution.
  • Ekip C Dip LSI electronic trip unit with adjustable protection functions.
  • Four-pole fixed configuration for comprehensive circuit isolation.
  • Front terminal connections simplify installation and maintenance.
  • Excellent short-circuit breaking capacity for demanding applications.

Key Features

  • ABB SACE Tmax XT series.
  • Product ID: 1SDA068505R1.
  • Model: XT4S 250 Ekip C Dip LSI In=250A 4P F F.
  • 250 A rated current.
  • 250 A frame size.
  • Ekip C Dip LSI electronic release.
  • Four-pole fixed MCCB.
  • Front bolt terminal connections.
  • Designed in accordance with IEC 60947-2.

Reliable Protection for Industrial Power Distribution

The ABB SACE Tmax XT4S range protects low-voltage electrical systems against overloads and short circuits while providing outstanding reliability and operational continuity. The electronic trip unit enables accurate protection settings, helping to minimise downtime and protect valuable electrical equipment.

The XT4S 250 frame is widely specified by panel builders, electrical contractors and machine manufacturers where dependable protection, compact dimensions and long service life are essential.

Typical Applications

  • Main incoming and feeder protection.
  • Industrial switchboards and distribution panels.
  • Motor control centres.
  • OEM machinery and electrical control panels.
  • Commercial building electrical installations.
  • Infrastructure and utility power distribution.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Trip Unit LSI
Current 250 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 50 kA
Manufacturer ABB
Series SACE Tmax XT
Product ID 1SDA068505R1
EAN 8015644024116
Extended product type XT4S 250 Ekip C Dip LSI In=250A 4P F F
Product type Moulded Case Circuit Breaker (MCCB)
Frame size XT4
Rated current (In) 250 A
Rated uninterrupted current (Iu) 250 A
Number of poles 4
Release type Ekip C Dip LSI electronic
Current type AC
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 8 kV
Rated frequency 50 / 60 Hz
Rated ultimate short-circuit breaking capacity (Icu) 50 kA at 415 V AC
Rated service short-circuit breaking capacity (Ics) 50 kA at 415 V AC
Short-circuit performance level S
Terminal connection type Front terminals
Terminal type Bolt
Mounting type Fixed
Standards IEC 60947-2
Dimensions (H × W × D) 160 × 140 × 82.5 mm
Weight approx. 3.05 kg
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA068505R1 used for?

This moulded case circuit breaker protects low-voltage electrical systems against overloads and short circuits in industrial, commercial and OEM applications.

What is the rated current of this MCCB?

The breaker has a 250 A rated current.

What trip unit is fitted?

The breaker is equipped with an Ekip C Dip LSI electronic trip unit providing long-time, short-time and instantaneous protection.

How many poles does this circuit breaker have?

This model is supplied as a 4-pole fixed MCCB with front terminal connections.

Where is this breaker typically installed?

It is typically installed in switchboards, distribution panels, motor control centres and OEM electrical assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are trusted worldwide by electrical engineers, machine builders and panel manufacturers for dependable circuit protection, robust construction and long operational life.