ABB XT4S 250 3 pole Standard MCCB Electronic trip unit LS/I Ii=250A

ABB XT4S 250 3 pole Standard MCCB Electronic trip unit LS/I Ii=250A

ABB XT4S 250 three-pole moulded case circuit breaker with 250 A Ekip Dip LS/I electronic trip unit for industrial low voltage power distribution.

SKU: 1SDA068475R1Alt SKU: XT4S 250 Ekip Dip LS/I In=250A 3p F FMPN: 1SDA068475R1
Price
List Price £1,179.86 ex VAT
Your Price (ex VAT) Save 25%
£884.90 25% OFF
You save £294.97 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £884.90
Trade pricing is personalised to your account

Manufacturer Lead Time

£884.90

Why Choose the ABB 1SDA068475R1 XT4S 250 MCCB?

The ABB 1SDA068475R1 is a high-performance ABB SACE Tmax XT4S moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection for industrial and commercial low voltage power distribution systems. As part of the advanced ABB Tmax XT series, this breaker combines compact construction, electronic protection and reliable breaking performance for demanding electrical installations.

Featuring a 250 A Ekip Dip LS/I electronic trip unit, the XT4S 250 delivers accurate protection against overloads and fault currents while offering adjustable protection settings for a wide range of applications. Its fixed three-pole construction with front terminals enables straightforward installation in switchboards, distribution panels and OEM equipment.

Designed in accordance with IEC 60947-2, the ABB XT4S 250 offers reliable operation, long mechanical endurance and high short-circuit breaking performance, making it an excellent choice for industrial automation, machinery and power distribution systems.

Key Advantages

  • ABB SACE Tmax XT4S moulded case circuit breaker.
  • 250 A rated current with Ekip Dip LS/I electronic protection.
  • Three-pole fixed configuration.
  • Front terminal connections for straightforward installation.
  • Adjustable overload and short-circuit protection.
  • Suitable for industrial, commercial and OEM electrical systems.

Key Features

  • ABB SACE Tmax XT series.
  • XT4S 250 frame size.
  • 250 A rated current.
  • Ekip Dip LS/I electronic trip unit.
  • 3-pole fixed breaker.
  • Front terminal connections.
  • Rated operational voltage up to 690 V AC.
  • Rated insulation voltage of 1000 V.
  • Breaking capacity up to 50 kA at 415 V AC.
  • Designed to IEC 60947-2.

Accurate Electronic Protection for Industrial Installations

The ABB XT4S Ekip Dip LS/I range uses electronic protection technology to monitor electrical conditions and disconnect circuits during overload or short-circuit faults. This helps protect cables, switchgear, machinery and connected equipment while supporting safer and more reliable low voltage power distribution.

With flexible protection settings and ABB's proven Tmax XT platform, the XT4S 250 is widely specified by panel builders, OEM manufacturers and electrical contractors for industrial and commercial installations.

Typical Applications

  • Industrial switchboards.
  • Power distribution panels.
  • OEM machinery.
  • Motor control centres.
  • Commercial electrical installations.
  • Industrial automation systems.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Trip Unit LS/I
Current 250 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Breaking Capacity 50 kA
Manufacturer ABB
Series SACE Tmax XT
Product ID 1SDA068475R1
Model XT4S 250 Ekip Dip LS/I In=250A 3p F F
Product type Moulded Case Circuit Breaker (MCCB)
Rated current (In) 250 A
Rated uninterrupted current (Iu) 250 A
Frame size XT4S 250
Trip unit Ekip Dip LS/I electronic release
Release type Solid-state electronic
Number of poles 3
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated ultimate breaking capacity (Icu) 50 kA at 415 V AC
Rated frequency 50 / 60 Hz
Connection type Front terminals
Mounting type Fixed
Dimensions (H × W × D) 160 × 105 × 82.5 mm
Weight Approx. 2.5 kg
Standards IEC 60947-2
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA068475R1 used for?

This moulded case circuit breaker protects low voltage electrical systems against overloads and short circuits in industrial and commercial applications.

What is the rated current of this MCCB?

The ABB 1SDA068475R1 has a 250 A rated current.

What type of trip unit is fitted?

The breaker is fitted with an Ekip Dip LS/I electronic trip unit providing adjustable overload and short-circuit protection.

How many poles does this breaker have?

This model is supplied in a 3-pole configuration for three-phase electrical systems.

Where is the XT4S Ekip Dip LS/I range commonly installed?

It is widely used in industrial switchboards, distribution panels, OEM machinery and commercial power distribution installations.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are trusted by panel builders, machine manufacturers and industrial engineers worldwide for delivering dependable protection, outstanding reliability and long operational life.