ABB XT4S 250 4 pole Standard MCCB Adjustable Thermal-Magnetic Release In=250A Ii=2500A

ABB XT4S 250 4 pole Standard MCCB Adjustable Thermal-Magnetic Release In=250A Ii=2500A

ABB 1SDA068326R1 SACE Tmax XT4S four-pole moulded case circuit breaker with 250 A TMA thermomagnetic trip unit and 50% rated neutral for industrial power distribution.

SKU: 1SDA068326R1Alt SKU: XT4S 250 TMA 250-2500 4p F F InN=50%MPN: 1SDA068326R1
Price
List Price £1,362.66 ex VAT
Your Price (ex VAT) Save 25%
£1,022.00 25% OFF
You save £340.67 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,022.00
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,022.00

Why Choose the ABB 1SDA068326R1 Tmax XT4S Moulded Case Circuit Breaker?

The ABB 1SDA068326R1 is a high performance Tmax XT4S moulded case circuit breaker (MCCB) engineered to provide dependable overload and short circuit protection for low voltage electrical distribution systems. As part of the trusted ABB SACE Tmax XT series, it is designed for industrial, commercial and infrastructure applications requiring reliable power protection.

This fixed four-pole MCCB features a TMA thermomagnetic trip unit with adjustable thermal overload protection and adjustable instantaneous magnetic short circuit protection. The neutral pole is rated at 50% of the phase current, making it suitable for installations where reduced neutral loading is expected.

With a 250 A rated current, 250 A frame size, 690 V AC operating voltage and a 50 kA breaking capacity at 415 V AC, the ABB 1SDA068326R1 provides robust circuit protection for feeders, switchboards, OEM machinery and industrial power distribution systems.

Key Advantages

  • High quality ABB Tmax XT4S moulded case circuit breaker.
  • 250 A rated current for industrial power distribution.
  • Four-pole fixed MCCB with 50% rated neutral.
  • TMA thermomagnetic release for overload and short circuit protection.
  • Adjustable instantaneous trip setting from 1250 to 2500 A.
  • 50 kA breaking capacity at 415 V AC.
  • Compact XT4 frame simplifies switchboard installation.
  • Manufactured in accordance with IEC 60947-2.

Key Features

  • ABB SACE Tmax XT4S series.
  • Product code: 1SDA068326R1.
  • Rated current: 250 A.
  • 250 A frame size.
  • Four-pole fixed configuration.
  • Neutral pole rated at 50% of phase current.
  • TMA thermomagnetic trip unit.
  • Thermal setting range: 175 to 250 A.
  • Instantaneous trip setting: 1250 to 2500 A.
  • Front terminal connections.

Reliable Protection for Industrial Power Distribution

The ABB Tmax XT4S range is designed to disconnect electrical circuits safely during overload and short circuit fault conditions, helping protect cables, switchgear and connected equipment while supporting reliable operation across low voltage electrical installations.

The ABB 1SDA068326R1 combines compact dimensions, high interrupting performance and adjustable thermomagnetic protection with a reduced neutral rating, making it suitable for modern switchboards, OEM machinery and demanding industrial distribution systems.

Typical Applications

  • Main and sub-distribution boards.
  • Industrial switchboards.
  • Commercial electrical installations.
  • Four-pole distribution circuits.
  • Motor feeder protection.
  • OEM machinery and control panels.
  • Infrastructure projects.
  • Low voltage electrical systems.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Current 250 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 50 kA
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax XT
Model XT4S 250 TMA 250-2500 4P F F InN=50%
Product code 1SDA068326R1
EAN 8015644696368
Product type Moulded Case Circuit Breaker (MCCB)
Number of poles 4
Frame size XT4
Rated current (In) 250 A
Rated uninterrupted current (Iu) 250 A
Neutral rating 50% of phase current
Trip unit TMA thermomagnetic
Thermal setting range 175 to 250 A
Instantaneous trip setting (Ii) 1250 to 2500 A
Rated operational voltage 690 V AC / 750 V DC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Frequency 50 / 60 Hz
Breaking capacity (Icu) 50 kA at 415 V AC
Short circuit performance level S
Protection rating IP20
Terminal type Front terminals
Mounting Fixed
Dimensions (H × W × D) approx. 160 × 140 × 82.5 mm
Weight approx. 3.5 kg
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA068326R1 used for?

It protects low voltage electrical distribution systems against overloads and short circuits in industrial and commercial applications.

What is the rated current of this MCCB?

The ABB 1SDA068326R1 has a 250 A rated current within a 250 A XT4 frame.

What does InN = 50% mean?

The neutral pole is rated at 50% of the phase current, making it suitable for installations where the neutral conductor carries a reduced load.

What type of trip unit is fitted?

The breaker incorporates a TMA thermomagnetic trip unit with adjustable overload and magnetic short circuit protection.

Where is this breaker typically installed?

It is commonly installed in industrial switchboards, OEM machinery, commercial distribution panels and electrical power distribution systems.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers are trusted worldwide by panel builders, OEM manufacturers and electrical engineers for dependable protection, long service life and reliable operation in demanding industrial environments.