ABB XT4S 250 3 pole Standard MCCB Adjustable Thermal-Magnetic Release In=225A Ii=2250A

ABB XT4S 250 3 pole Standard MCCB Adjustable Thermal-Magnetic Release In=225A Ii=2250A

ABB 1SDA068311R1 SACE Tmax XT4S three-pole moulded case circuit breaker with 225 A TMA thermomagnetic trip unit for industrial power distribution and electrical protection.

SKU: 1SDA068311R1Alt SKU: XT4S 250 TMA 225-2250 3p F FMPN: 1SDA068311R1
Price
List Price £1,000.33 ex VAT
Your Price (ex VAT) Save 25%
£750.25 25% OFF
You save £250.08 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £750.25
Trade pricing is personalised to your account

Manufacturer Lead Time

£750.25

Why Choose the ABB 1SDA068311R1 Tmax XT4S Moulded Case Circuit Breaker?

The ABB 1SDA068311R1 is a high performance Tmax XT4S moulded case circuit breaker (MCCB) designed to protect low voltage electrical distribution systems against overloads and short circuits. As part of the dependable ABB SACE Tmax XT series, it provides reliable circuit protection for industrial, commercial and infrastructure applications.

This fixed three-pole MCCB features a TMA thermomagnetic trip unit, combining thermal overload protection with adjustable instantaneous magnetic short circuit protection. Its front terminal configuration supports efficient installation in switchboards, distribution boards and control panels.

With a 225 A rated current, 250 A frame size, 690 V AC operating voltage and high short circuit performance, the ABB 1SDA068311R1 is well suited to demanding electrical installations where safety, reliability and compact panel integration are essential.

Key Advantages

  • High quality ABB Tmax XT4S moulded case circuit breaker.
  • 225 A rated current for industrial power distribution.
  • Three-pole fixed MCCB with front terminals.
  • TMA thermomagnetic release for overload and short circuit protection.
  • Adjustable magnetic trip range from 1125 to 2250 A.
  • Compact XT4 frame for efficient switchboard design.
  • Reliable protection for feeders, panels and machinery circuits.
  • Manufactured in accordance with IEC 60947-2.

Key Features

  • ABB SACE Tmax XT4S series.
  • Product code: 1SDA068311R1.
  • Rated current: 225 A.
  • 250 A frame size.
  • Three-pole fixed configuration.
  • TMA thermomagnetic trip unit.
  • Magnetic trip setting: 1125 to 2250 A.
  • Operating voltage: up to 690 V AC.
  • Front terminal connections.
  • IP20 protection rating.

Reliable Protection for Industrial Power Distribution

Moulded case circuit breakers such as the ABB Tmax XT4S are designed to disconnect electrical circuits during overload or short circuit fault conditions. This helps protect cables, equipment and downstream circuits while supporting safe, reliable operation across low voltage installations.

The ABB 1SDA068311R1 combines compact construction, strong short circuit performance and adjustable thermomagnetic protection, making it suitable for modern switchboards, industrial panels and demanding distribution applications.

Typical Applications

  • Main and sub-distribution boards.
  • Industrial switchboards.
  • Commercial electrical panels.
  • Manufacturing facilities.
  • Feeder and machinery protection.
  • OEM control panels.
  • Infrastructure and utilities.
  • Low voltage power distribution systems.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Current 225 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax XT
Model XT4S 250 TMA 225-2250 3P F F
Product code 1SDA068311R1
EAN 8015644022174
Product type Moulded Case Circuit Breaker (MCCB)
Number of poles 3
Frame size XT4
Rated current (In) 225 A
Rated uninterrupted current (Iu) 250 A
Trip unit TMA thermomagnetic
Instantaneous trip setting (I3) 1125 to 2250 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Frequency 50 / 60 Hz
Breaking capacity class S
Protection rating IP20
Terminal type Front terminals
Mounting Fixed
Dimensions (H × W × D) approx. 160 × 105 × 82.5 mm
Weight approx. 2.5 kg
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA068311R1 used for?

It is used to protect low voltage electrical distribution systems against overloads and short circuits in industrial, commercial and infrastructure applications.

What is the rated current of this MCCB?

The ABB 1SDA068311R1 has a 225 A rated current within a 250 A XT4 frame.

What type of trip unit does this breaker use?

This model uses a TMA thermomagnetic trip unit with adjustable magnetic short circuit protection.

How many poles does the ABB 1SDA068311R1 have?

It is a three-pole fixed moulded case circuit breaker with front terminals.

Where is this breaker typically installed?

It is typically installed in switchboards, distribution panels, industrial control panels, OEM equipment and machinery protection systems.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers are trusted by panel builders, electrical engineers and industrial maintenance teams worldwide for dependable protection, compact installation and long term operational performance.