ABB XT4S 250 3 pole Standard MCCB Adjustable Thermal-Magnetic Release In=200A Ii=2000A

ABB XT4S 250 3 pole Standard MCCB Adjustable Thermal-Magnetic Release In=200A Ii=2000A

ABB 1SDA068310R1 SACE Tmax XT4S three-pole moulded case circuit breaker with 200 A TMA thermomagnetic trip unit for industrial power distribution and electrical protection.

SKU: 1SDA068310R1Alt SKU: XT4S 250 TMA 200-2000 3p F FMPN: 1SDA068310R1
Price
List Price £1,000.33 ex VAT
Your Price (ex VAT) Save 25%
£750.25 25% OFF
You save £250.08 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £750.25
Trade pricing is personalised to your account

Manufacturer Lead Time

£750.25

Why Choose the ABB 1SDA068310R1 Tmax XT4S Moulded Case Circuit Breaker?

The ABB 1SDA068310R1 is a high performance Tmax XT4S moulded case circuit breaker (MCCB) designed to provide reliable overload and short circuit protection for low voltage electrical distribution systems. As part of the trusted ABB SACE Tmax XT series, it is engineered for industrial, commercial and infrastructure applications where dependable circuit protection is essential.

This fixed three-pole MCCB features a TMA thermomagnetic trip unit, combining adjustable thermal overload protection with instantaneous magnetic short circuit protection. Its front terminal configuration supports straightforward installation in switchboards and control panels, while the compact XT4 frame helps maximise space efficiency.

With a 200 A rated current, 250 A frame size, 690 V AC operating voltage and 50 kA breaking capacity at 415 V AC, the ABB 1SDA068310R1 is ideal for protecting feeders, distribution boards, machinery and industrial electrical systems.

Key Advantages

  • High quality ABB Tmax XT4S moulded case circuit breaker.
  • 200 A rated current for industrial power distribution.
  • Three-pole fixed configuration with front terminals.
  • TMA thermomagnetic release for overload and short circuit protection.
  • Adjustable magnetic trip range from 1000 to 2000 A.
  • 50 kA breaking capacity at 415 V AC.
  • Compact XT4 design for efficient panel integration.
  • Manufactured in accordance with IEC 60947-2.

Key Features

  • ABB SACE Tmax XT4S series.
  • Product code: 1SDA068310R1.
  • Rated current: 200 A.
  • 250 A frame size.
  • Three-pole fixed MCCB.
  • TMA thermomagnetic trip unit.
  • Magnetic trip setting: 1000 to 2000 A.
  • Operating voltage: up to 690 V AC.
  • Front terminal connections.
  • IP20 protection rating.

Reliable Protection for Industrial Power Distribution

Moulded case circuit breakers such as the ABB Tmax XT4S help protect electrical systems by disconnecting circuits during overload or short circuit fault conditions. This helps reduce equipment damage, improve installation safety and support reliable operation across industrial and commercial power networks.

The ABB 1SDA068310R1 provides a strong combination of compact construction, high breaking capacity and adjustable thermomagnetic protection, making it suitable for modern switchboards, machinery panels and demanding distribution applications.

Typical Applications

  • Main and sub-distribution boards.
  • Industrial switchboards.
  • Commercial electrical panels.
  • Manufacturing facilities.
  • Feeder and machinery protection.
  • OEM control panels.
  • Infrastructure and utilities.
  • Low voltage power distribution systems.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Current 200 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Breaking Capacity 50 kA
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax XT
Model XT4S 250 TMA 200-2000 3P F F
Product code 1SDA068310R1
EAN 8015644022167
Product type Moulded Case Circuit Breaker (MCCB)
Number of poles 3
Frame size XT4
Rated current (In) 200 A
Rated uninterrupted current (Iu) 250 A
Trip unit TMA thermomagnetic
Instantaneous trip setting (I3) 1000 to 2000 A
Rated operational voltage 690 V AC / 750 V DC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Frequency 50 / 60 Hz
Breaking capacity (Icu) 50 kA at 415 V AC
Protection rating IP20
Terminal type Front terminals
Mounting Fixed
Dimensions (H × W × D) approx. 160 × 105 × 82.5 mm
Weight approx. 2.5 kg
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA068310R1 used for?

It is used to protect low voltage electrical distribution systems against overloads and short circuits in industrial, commercial and infrastructure applications.

What is the rated current of this MCCB?

The ABB 1SDA068310R1 has a 200 A rated current within a 250 A XT4 frame.

What type of trip unit does this breaker use?

This model uses a TMA thermomagnetic trip unit with adjustable overload and magnetic short circuit protection.

How many poles does the ABB 1SDA068310R1 have?

It is a three-pole fixed moulded case circuit breaker with front terminals.

Where is this breaker typically installed?

It is typically installed in switchboards, distribution panels, industrial control panels, OEM equipment and machinery protection systems.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers are trusted by panel builders, electrical engineers and industrial maintenance teams worldwide for reliable protection, compact installation and long term operational performance.