1SDA068181R1 ABB XT4L 250 Breaking Part 4p F F

1SDA068181R1 ABB XT4L 250 Breaking Part 4p F F

ABB 1SDA068181R1 XT4L 250 BREAKING PART 4p F F is a four-pole fixed Tmax XT4 moulded case circuit breaker breaking part with front terminals, a 250 A frame size and 120 kA ultimate breaking capacity at 415 V AC for combination with compatible ABB XT4 protection trip units.

SKU: 1SDA068181R1MPN: 1SDA068181R1
Price
List Price £917.05 ex VAT
Your Price (ex VAT) Save 25%
£687.79 25% OFF
You save £229.26 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £687.79
Trade pricing is personalised to your account

Manufacturer Lead Time

£687.79

Why Choose the ABB XT4L 250 Breaking Part 4p F F?

The ABB XT4L 250 BREAKING PART 4p F F, order code 1SDA068181R1, is a four-pole moulded case circuit breaker breaking part from the ABB SACE Tmax XT range. Designed around the XT4 250 frame, it provides the switching and high-fault-current interruption section required for building a compatible modular Tmax XT4 circuit-breaker assembly.

This version is a fixed four-pole breaking part with front terminals and is designed for the 250 A XT4 frame size. The XT4L configuration provides a high ultimate short-circuit breaking capacity of 120 kA at 415 V AC, making it suitable for demanding industrial and commercial distribution systems where high prospective fault currents are present.

Unlike a complete MCCB supplied with an integral protection release, the 1SDA068181R1 is the breaking part intended for combination with a compatible ABB XT4 trip unit. This modular architecture allows the protection release to be selected according to the required current rating and protection functions, including compatible thermomagnetic and electronic protection solutions within the Tmax XT4 platform.

Key Advantages

  • Genuine ABB SACE Tmax XT4 breaking part for modular circuit-breaker configurations.
  • 250 A XT4 frame size for substantial low-voltage distribution loads.
  • Four-pole configuration for three-phase systems with neutral switching.
  • High 120 kA ultimate breaking capacity at 415 V AC.
  • L-level interruption performance for installations with high prospective fault currents.
  • Rated for electrical systems up to 690 V.
  • Fixed construction with front terminals for straightforward switchboard integration.
  • Modular design enables selection of a compatible ABB XT4 protection trip unit.
  • Suitable for industrial, infrastructure, commercial and OEM power-distribution applications.

Key Features

  • ABB SACE Tmax XT series.
  • XT4L 250 breaking part.
  • L-level short-circuit performance.
  • Four-pole configuration.
  • 250 A frame size.
  • 120 kA Icu at 415 V AC.
  • 690 V rated voltage.
  • Fixed mounting arrangement.
  • Front terminal connections.
  • Designed for combination with compatible ABB XT4 trip units.
  • Modular construction supports configurable protection solutions.

High-Performance Modular Tmax XT4 Breaking-Part Technology

A circuit-breaker breaking part provides the current-carrying contacts, operating mechanism and fault-interruption capability of the MCCB while allowing the protection release to be selected separately. The ABB XT4L 250 breaking part can therefore be combined with a compatible XT4 trip unit to create a circuit-breaker configuration tailored to the required current rating, protection functions and electrical installation.

The XT4L platform is particularly suited to applications requiring substantial short-circuit interruption performance, providing an Icu of 120 kA at 415 V AC. Its four-pole, fixed, front-connected construction makes the 1SDA068181R1 a flexible foundation for high-performance ABB Tmax XT4 protection assemblies in industrial switchboards, distribution systems and OEM electrical equipment.

Typical Applications

  • Modular ABB Tmax XT4 circuit-breaker assemblies.
  • Industrial low-voltage power distribution systems.
  • Four-pole three-phase distribution circuits.
  • Electrical switchboards and distribution panels.
  • High prospective short-circuit current installations.
  • Feeder and main distribution protection assemblies.
  • Industrial machinery and automation panels.
  • Commercial and infrastructure electrical systems.
  • OEM electrical equipment and panel building.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA068181R1
Product type Moulded case circuit breaker breaking part
Frame size XT4
Frame designation 250
Short-circuit performance level L
Number of poles 4
Ultimate breaking capacity (Icu) at 415 V AC 120 kA
Rated voltage 690 V
Mounting Fixed
Terminal position Front
Dimensions (W × H × D) 140 × 160 × 82.5 mm
Net weight 2.65 kg
EAN / GTIN 8015644020781
Minimum order quantity 1 piece
Customs tariff number 85362090
Standard IEC / EN 60947-2

Frequently Asked Questions

What is the ABB 1SDA068181R1?

The ABB 1SDA068181R1 is an XT4L 250 four-pole fixed breaking part with front terminals from the SACE Tmax XT range, designed to provide the switching and short-circuit interruption section of a modular XT4 moulded case circuit-breaker assembly.

Is the ABB 1SDA068181R1 a complete protected circuit breaker?

The 1SDA068181R1 is specified as an XT4L 250 breaking part and is intended for combination with a compatible ABB XT4 protection trip unit selected according to the required circuit protection characteristics.

What frame size is the ABB XT4L breaking part?

The 1SDA068181R1 uses the ABB Tmax XT4 250 frame and has a four-pole configuration. Compatible protection trip units can be selected to create the required XT4 circuit-breaker assembly.

What is the breaking capacity of the ABB XT4L 250?

The XT4L 250 breaking part provides an ultimate short-circuit breaking capacity of 120 kA at 415 V AC, making it suitable for installations with high prospective fault currents.

How is the ABB 1SDA068181R1 installed?

The 1SDA068181R1 is a fixed four-pole breaking part with front terminals. Its dimensions are approximately 140 × 160 × 82.5 mm, supporting integration into industrial switchboards, distribution panels and OEM electrical equipment.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit-breaker components are widely used by panel builders, electrical engineers and OEMs to create compact, modular and high-performance protection solutions for low-voltage electrical distribution systems.