ABB XT4N 250 4 pole Normal MCCB Electronic trip unit I Ii=250A

ABB XT4N 250 4 pole Normal MCCB Electronic trip unit I Ii=250A

ABB 1SDA068152R1 SACE Tmax XT4N 250 Ekip I moulded case circuit breaker with 250 A rated current, four-pole configuration, fixed mounting and front terminals for industrial electrical distribution.

SKU: 1SDA068152R1Alt SKU: XT4N 250 Ekip I In=250A 4p F FMPN: 1SDA068152R1
Price
List Price £1,387.76 ex VAT
Your Price (ex VAT) Save 25%
£1,040.82 25% OFF
You save £346.94 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,040.82
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,040.82

Why Choose the ABB 1SDA068152R1 SACE Tmax XT4N MCCB?

The ABB 1SDA068152R1 is a robust SACE Tmax XT4N moulded case circuit breaker (MCCB) designed to provide reliable protection for low voltage electrical distribution systems. Built for industrial and commercial power applications, this four-pole breaker combines high breaking performance with ABB's advanced electronic protection technology.

Featuring an integrated Ekip I electronic trip unit, the XT4N provides accurate overload and short-circuit protection for demanding installations. Its fixed design with front terminals makes it suitable for switchboards, distribution panels and control assemblies where dependable circuit protection and straightforward installation are essential.

With a 250 A rated current, 690 V AC rated operational voltage and an XT4N frame size, the ABB 1SDA068152R1 is ideal for protecting feeders, machinery circuits, motor control centres and industrial power distribution networks.

Key Advantages

  • High quality ABB SACE Tmax XT4N moulded case circuit breaker.
  • 250 A rated current for industrial and commercial power distribution.
  • Four-pole fixed configuration with front terminal connections.
  • Advanced Ekip I electronic trip unit for accurate protection.
  • Reliable overload and short-circuit protection.
  • Compact construction supports efficient panel and switchboard installation.

Key Features

  • ABB SACE Tmax XT series.
  • Model XT4N 250 Ekip I.
  • 250 A rated current (In).
  • 690 V AC rated operational voltage.
  • Four-pole (4P) configuration.
  • Ekip I electronic protection release.
  • Front terminal connections.
  • Fixed mounting execution.
  • Designed for low voltage electrical distribution systems.

Reliable Circuit Protection for Industrial Distribution

Moulded case circuit breakers such as the ABB SACE Tmax XT4N protect electrical systems by interrupting fault currents and preventing damage caused by overloads and short circuits. This helps maintain safe operation across distribution networks, machinery circuits and power control systems.

The XT4N series is widely used by panel builders, electrical contractors and industrial engineers who require dependable performance, compact installation and precise protection within modern low voltage switchgear.

Typical Applications

  • Industrial power distribution systems.
  • Electrical switchboards and distribution panels.
  • Motor control centres.
  • Manufacturing and processing facilities.
  • Commercial building electrical infrastructure.
  • OEM machinery and automation systems.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Trip Unit I
Current 250 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 36 kA
Manufacturer ABB
Series SACE Tmax XT
Model XT4N 250 Ekip I In=250A 4p F F
Product code 1SDA068152R1
Product type Moulded Case Circuit Breaker (MCCB)
Frame size XT4
Rated current 250 A
Number of poles 4
Trip unit Ekip I electronic release
Rated operational voltage 690 V AC
Rated frequency 50 / 60 Hz
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Breaking capacity at 415 V AC (Icu) 36 kA
Terminal type Front terminals
Mounting Fixed
Standards IEC / CE
Dimensions (H × W × D) approx. 160 × 140 × 82.5 mm
Weight approx. 3.1 kg
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA068152R1 used for?

This MCCB is used to protect low voltage electrical circuits against overloads and short circuits in industrial and commercial power distribution systems.

What is the rated current of this circuit breaker?

The ABB 1SDA068152R1 has a rated current of 250 A.

How many poles does this MCCB have?

This model features a four-pole (4P) configuration.

Which trip unit is fitted to this breaker?

The breaker is fitted with an ABB Ekip I electronic trip unit for accurate overload and short-circuit protection.

Where is the ABB 1SDA068152R1 typically installed?

It is typically installed in switchboards, distribution panels, motor control centres and industrial electrical assemblies.

Trusted by Electrical Professionals Worldwide