ABB XT4N 250 4 pole Normal MCCB Adjustable Thermal-Magnetic Release In=225A Ii=2250A

ABB XT4N 250 4 pole Normal MCCB Adjustable Thermal-Magnetic Release In=225A Ii=2250A

ABB XT4N 250 moulded case circuit breaker with 225 A thermal magnetic trip unit, fixed four-pole design and front terminals for industrial power distribution.

SKU: 1SDA068110R1Alt SKU: XT4N 250 TMA 225-2250 4p F F InN=100%MPN: 1SDA068110R1
Price
List Price £1,268.59 ex VAT
Your Price (ex VAT) Save 25%
£951.44 25% OFF
You save £317.15 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £951.44
Trade pricing is personalised to your account

Manufacturer Lead Time

£951.44

Why Choose the ABB 1SDA068110R1 XT4N 250 TMA 225 MCCB?

The ABB 1SDA068110R1 is a high-performance ABB SACE Tmax XT4N moulded case circuit breaker (MCCB) engineered to provide dependable protection for low voltage electrical distribution systems. Designed for industrial and commercial installations, this fixed four-pole circuit breaker combines robust overload and short circuit protection with ABB's proven reliability.

Featuring a 225 A thermal magnetic (TMA) trip unit, front terminals and a fully rated neutral, the XT4N delivers excellent protection for feeders, switchboards, distribution panels and critical power circuits. As part of the ABB SACE Tmax XT range, it offers compact dimensions, high breaking performance and long mechanical life while complying with IEC 60947-2 standards.

The ABB XT4N 250 is suitable for applications requiring reliable circuit protection up to 690 V AC. Its thermal magnetic release provides dependable overload protection together with rapid magnetic tripping during short circuit conditions, helping minimise equipment damage and improve electrical system safety.

Key Advantages

  • 225 A moulded case circuit breaker for industrial power distribution.
  • Fixed 4-pole design with fully rated neutral.
  • Thermal magnetic (TMA) trip unit for overload and short circuit protection.
  • Compact ABB SACE Tmax XT4 frame saves panel space.
  • Front terminal connections simplify installation.
  • Suitable for demanding industrial and commercial electrical systems.

Key Features

  • ABB SACE Tmax XT4N series.
  • Product code: 1SDA068110R1.
  • Rated current: 225 A.
  • 4-pole fixed MCCB.
  • Thermal magnetic TMA release.
  • Front terminal connections.
  • Rated operational voltage up to 690 V AC.
  • Designed in accordance with IEC 60947-2.

Reliable Protection for Electrical Distribution Systems

The ABB XT4N series is designed to protect electrical installations against overloads and short circuits while maintaining dependable operation in demanding industrial environments. Its thermal magnetic trip unit provides accurate protection across a wide range of operating conditions.

Whether installed within manufacturing plants, commercial buildings, infrastructure or OEM control panels, the ABB 1SDA068110R1 delivers dependable circuit protection, excellent durability and straightforward installation as part of modern low voltage power distribution systems.

Typical Applications

  • Industrial switchboards.
  • Power distribution panels.
  • Commercial electrical installations.
  • Motor distribution systems.
  • OEM machinery and equipment.
  • Infrastructure and process industries.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Current 225 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax XT
Model XT4N 250 TMA 225-2250 4P F F
Product code 1SDA068110R1
Product type Moulded Case Circuit Breaker (MCCB)
Frame size XT4
Rated current (In) 225 A
Rated uninterrupted current (Iu) 250 A
Number of poles 4
Trip unit Thermal Magnetic (TMA)
Instantaneous trip setting (Ii) 1125 to 2250 A
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Frequency 50 / 60 Hz
Mounting Fixed panel mounting
Terminal type Front terminals
Dimensions (H × W × D) Approx. 160 × 140 × 82.5 mm
Weight Approx. 3.5 kg
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA068110R1 used for?

It is a four-pole moulded case circuit breaker designed to protect low voltage electrical circuits against overloads and short circuits.

What is the rated current of this MCCB?

The ABB 1SDA068110R1 has a 225 A rated current with a thermal magnetic trip unit.

How many poles does this circuit breaker have?

This model is supplied as a 4-pole fixed circuit breaker with a fully rated neutral.

What type of trip unit is fitted?

The breaker uses an ABB TMA thermal magnetic release providing overload and instantaneous short circuit protection.

Where is this MCCB typically installed?

It is commonly installed in industrial switchboards, distribution panels, commercial buildings and OEM electrical control systems.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are trusted by electrical engineers, panel builders and industrial facilities worldwide for dependable protection, long service life and high performance in critical power distribution applications.