1SDA068027R1 ABB XT2V 160 Ekip LSIG In=160A 4P Fixed Circuit Breaker with 100% Neutral

1SDA068027R1 ABB XT2V 160 Ekip LSIG In=160A 4P Fixed Circuit Breaker with 100% Neutral

ABB 1SDA068027R1 is an XT2V 160 four-pole fixed moulded case circuit breaker with front terminals, a 160 A rated current, a 100% fully rated neutral and an Ekip DIP LSIG solid-state electronic trip unit.

SKU: 1SDA068027R1MPN: 1SDA068027R1
Price
List Price £2,948.26 ex VAT
Your Price (ex VAT) Save 25%
£2,211.20 25% OFF
You save £737.07 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,211.20
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,211.20

Why Choose the ABB XT2V 160 Ekip LSIG In=160A 4P Fixed Circuit Breaker?

The ABB XT2V 160 Ekip LSIG In=160A 4P FF InN=100% is a high-performance moulded case circuit breaker (MCCB) designed for comprehensive protection of low-voltage AC power distribution systems. As part of the ABB SACE Tmax XT2 series, it combines the compact XT2 frame with an Ekip DIP LSIG solid-state electronic trip unit for dependable overload, short-circuit and ground-fault protection.

This XT2V configuration features a fixed four-pole construction with front terminals and a fully rated 100% neutral. Its V short-circuit performance class provides high fault-interruption capability, making the breaker suitable for demanding industrial, commercial and infrastructure distribution systems.

With a rated current of 160 A and an Ekip LSIG electronic protection release, the breaker provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. Its four-pole arrangement with fully rated neutral is particularly suitable for three-phase four-wire systems where the neutral conductor requires full-current capability and comprehensive electronic protection.

Key Advantages

  • High-performance ABB SACE Tmax XT2V moulded case circuit breaker.
  • 160 A rated current for low-voltage AC power distribution.
  • Ekip DIP LSIG electronic trip unit for comprehensive circuit protection.
  • Long-time, short-time, instantaneous and ground-fault protection functions.
  • Four-pole design with 100% fully rated neutral.
  • V short-circuit performance level for demanding fault-current conditions.
  • Fixed construction with front terminals for efficient switchboard integration.

Key Features

  • ABB SACE Tmax XT2 series.
  • XT2V 160 configuration.
  • 160 A rated current.
  • Ekip DIP LSIG solid-state electronic protection release.
  • LSIG protection functions for overload, short-circuit and ground-fault protection.
  • Four-pole configuration.
  • 100% fully rated neutral.
  • Fixed mounting arrangement.
  • Front terminal connections.
  • V interruption rating.
  • Rated voltage of 690 V AC.

Comprehensive Electronic Protection for Power Distribution

The ABB Tmax XT2V protects low-voltage electrical distribution systems by disconnecting circuits when damaging overload, short-circuit or ground-fault conditions occur. Its Ekip LSIG solid-state electronic release combines long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection within a compact MCCB platform.

The four-pole design incorporates a 100% fully rated neutral, allowing the neutral pole to carry the full rated current of the breaker. Combined with fixed mounting, front terminals and the high-performance XT2V platform, this makes the 1SDA068027R1 particularly suitable for three-phase four-wire distribution systems requiring comprehensive electronic protection and full neutral-current capability.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Commercial electrical distribution panels.
  • Three-phase four-wire power distribution systems.
  • Systems requiring a fully rated neutral conductor.
  • Circuits requiring LSIG electronic protection functions.
  • Power distribution systems with high prospective fault currents.
  • Infrastructure and building electrical systems.
  • OEM switchgear and electrical distribution assemblies.

Technical Specifications

Series SACE Tmax XT2
ABB order code 1SDA068027R1
Product type Moulded case circuit breaker
Frame size XT2
Rated current (In) 160 A
Protection release Ekip DIP LSIG solid-state electronic
Protection functions Long-time (L), short-time (S), instantaneous (I) and ground-fault (G)
Number of poles 4
Neutral rating 100% fully rated neutral
Mounting Fixed
Terminal arrangement Front terminals
Current type AC
Rated voltage 690 V AC
Short-circuit performance level V
Ultimate short-circuit breaking capacity (Icu) at 380–415 V AC 150 kA
Standard IEC
Product net weight 1.6 kg
EAN 8015644019235

Frequently Asked Questions

What is the ABB 1SDA068027R1?

The ABB 1SDA068027R1 is an XT2V 160 four-pole fixed moulded case circuit breaker with front terminals, a 160 A rated current, a fully rated neutral and an Ekip LSIG solid-state electronic protection release.

What is the rated current of the ABB XT2V 1SDA068027R1?

This XT2V circuit breaker has a rated current of 160 A.

What does LSIG mean on the Ekip trip unit?

LSIG identifies long-time overload protection, short-time short-circuit protection, instantaneous short-circuit protection and ground-fault protection.

What does InN=100% mean on the ABB 1SDA068027R1?

InN=100% means the neutral pole is fully rated, providing a neutral-current rating equal to 100% of the breaker's 160 A rated current.

What is the breaking capacity of this XT2V circuit breaker?

The XT2V configuration provides an ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC.

How is the ABB 1SDA068027R1 installed?

The breaker is supplied in a fixed four-pole configuration with front terminals for integration into suitable low-voltage switchboards, distribution panels and electrical assemblies.