1SDA068023R1 ABB XT2V 160 Ekip LSIG 25 A 4-Pole MCCB

1SDA068023R1 ABB XT2V 160 Ekip LSIG 25 A 4-Pole MCCB

ABB 1SDA068023R1 is an XT2V 160 four-pole fixed moulded case circuit breaker with a 25 A Ekip LSIG electronic trip unit, front terminals and high breaking performance for low-voltage AC electrical distribution.

SKU: 1SDA068023R1MPN: 1SDA068023R1
Price
List Price £2,774.14 ex VAT
Your Price (ex VAT) Save 25%
£2,080.61 25% OFF
You save £693.54 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,080.61
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,080.61

Why Choose the ABB XT2V 160 Ekip LSIG In=25A 4p F F Circuit Breaker?

The ABB XT2V 160 Ekip LSIG In=25A 4p F F, order code 1SDA068023R1, is a high-performance four-pole moulded case circuit breaker (MCCB) designed for protection and switching in industrial and commercial low-voltage electrical distribution systems. As part of the ABB Tmax XT range, it combines the compact XT2 frame with an Ekip LSIG solid-state electronic trip unit for comprehensive circuit protection.

This circuit breaker features a 25 A rated current and an Ekip LSIG electronic release, providing long-time, short-time, instantaneous and earth-fault protection functions. These electronic protection functions help safeguard cables, equipment and electrical distribution circuits against overloads, short circuits and earth faults while supporting effective coordination between protective devices.

The XT2V 160 is supplied in a fixed, four-pole configuration with front terminals and is designed for AC power distribution applications. It has a rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 150 kA at 400 V AC, making the V performance version suitable for demanding installations with high prospective fault currents.

Key Advantages

  • Compact ABB Tmax XT2 moulded case circuit breaker for low-voltage distribution.
  • 25 A rated current for industrial and commercial circuit protection.
  • Ekip LSIG electronic trip unit with long-time, short-time, instantaneous and earth-fault protection.
  • Four-pole configuration for three-phase distribution systems requiring four-pole switching.
  • Fixed mounting with front terminals for straightforward switchboard installation.
  • 150 kA ultimate breaking capacity at 400 V AC for demanding fault-current conditions.
  • Electronic protection supports precise circuit protection and improved selectivity.
  • Part of ABB's established Tmax XT circuit breaker platform.

Key Features

  • ABB Tmax XT2 frame.
  • XT2V 160 circuit breaker configuration.
  • 25 A rated current.
  • Ekip LSIG solid-state electronic release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • 4-pole construction.
  • Fixed installation.
  • Front terminal connection.
  • 690 V AC rated operational voltage.
  • 50 / 60 Hz rated frequency.
  • 8 kV rated impulse withstand voltage.
  • Designed to applicable IEC standards.

Advanced Electronic Protection for Electrical Distribution

The ABB Ekip LSIG trip unit monitors electrical conditions and initiates breaker operation when configured protection thresholds are exceeded. The long-time function protects against sustained overloads, while short-time and instantaneous functions provide protection against short-circuit currents. Integrated earth-fault protection provides an additional layer of protection for electrical distribution systems.

The four-pole construction makes the breaker suitable for three-phase distribution systems requiring four-pole switching. Combined with the compact XT2 frame, fixed mounting arrangement, front terminals and high V-class breaking performance, the 1SDA068023R1 provides a versatile protection solution for modern switchboards, machinery and industrial distribution panels.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Electrical switchboards and control panels.
  • Three-phase and neutral distribution circuits.
  • Machine and equipment power distribution.
  • Commercial electrical distribution systems.
  • Protection of cables and feeder circuits.
  • OEM machinery and automation panels.
  • Installations requiring electronic LSIG protection and high short-circuit breaking performance.

Technical Specifications

Series Tmax XT
Product group T-Max XT 250 Range
ABB order code 1SDA068023R1
EAN 8015644019198
Product type Moulded case circuit breaker (MCCB)
Frame size XT2
Frame designation XT2V 160
Rated current 25 A
Rated uninterrupted current 160 A
Rated operational voltage 690 V AC
Rated frequency 50 / 60 Hz
Rated impulse withstand voltage 8 kV
Ultimate breaking capacity at 400 V AC 150 kA
Number of poles 4
Trip unit Ekip LSIG solid-state electronic release
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Overload release setting range 10–25 A
Short-time short-circuit adjustment range 25–250 A
Instantaneous short-circuit adjustment range 25–250 A
Earth-fault protection Integrated
Mounting type Fixed
Terminal arrangement Front terminals
Breaking-capacity class V
Application AC electrical distribution
Standard IEC
Dimensions (H × W × D) 130 × 120 × 82.5 mm
Weight approx. 1.6 kg

Frequently Asked Questions

What is the ABB 1SDA068023R1 used for?

The ABB 1SDA068023R1 is a four-pole moulded case circuit breaker used for protection and switching of low-voltage AC electrical distribution circuits in industrial and commercial installations.

What is the rated current of this circuit breaker?

The XT2V 160 circuit breaker supplied under ABB order code 1SDA068023R1 has a rated current of 25 A.

What protection functions does the Ekip LSIG trip unit provide?

The Ekip LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection.

What is the breaking capacity of the ABB XT2V 160?

The XT2V version has an ultimate short-circuit breaking capacity of 150 kA at 400 V AC, providing high fault-current interruption performance for demanding electrical installations.

How is the ABB 1SDA068023R1 installed?

The 1SDA068023R1 is supplied as a fixed four-pole circuit breaker with front terminals, making it suitable for installation within switchboards and electrical control panels.

Trusted ABB Circuit Protection

ABB Tmax XT moulded case circuit breakers are widely used in industrial and commercial electrical distribution systems, combining compact construction, dependable switching performance and advanced electronic protection for modern low-voltage installations.