ABB 1SDA068016R1 XT2V 160 is a four-pole fixed moulded case circuit breaker with a 10 A Ekip DIP LSI electronic release, front bolt terminals and 150 kA ultimate breaking capacity at 415 V AC.
£1,583.94
The ABB XT2V 160 Ekip LSI In=10A 4p F F, order code 1SDA068016R1, is a high-performance four-pole moulded case circuit breaker (MCCB) designed for precise protection of low-voltage electrical distribution systems. Part of the ABB SACE Tmax XT2 range, it combines a compact 160 A frame with a 10 A Ekip LSI electronic release and ABB's high-performance V interruption level for demanding industrial, commercial and infrastructure applications.
This fixed circuit breaker incorporates an ABB Ekip DIP LSI solid-state electronic trip unit. The LSI release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection, allowing accurate electronic protection and effective selectivity and coordination with other protective devices within a low-voltage distribution system.
Rated for operation at up to 690 V AC, the XT2V 160 provides an ultimate short-circuit breaking capacity of 150 kA at 415 V AC and up to 200 kA at 230–240 V AC. Its fixed four-pole construction, front bolt terminals and compact 120 × 130 × 82.5 mm dimensions make it suitable for switchboards and distribution assemblies where high fault-current performance and four-pole switching are required.
Electronic circuit breakers equipped with an ABB Ekip LSI release provide precise protection against the principal overcurrent conditions encountered in low-voltage distribution systems. The long-time function protects against sustained overloads, while the short-time and instantaneous functions provide coordinated protection against short-circuit currents, helping improve selectivity between protective devices.
The combination of the 10 A Ekip DIP LSI release, four-pole construction and the XT2V circuit breaker's 150 kA Icu at 415 V AC makes the 1SDA068016R1 particularly suitable for lower-current circuits supplied from distribution systems with high prospective fault levels. Its compact XT2 frame also helps optimise switchboard space while providing advanced electronic circuit protection.
| Series | SACE Tmax XT2 |
|---|---|
| Product group | T-Max XT 250 Range |
| Order code | 1SDA068016R1 |
| Product type | Moulded case circuit breaker |
| Frame size | XT2 160 |
| Short-circuit performance level | V |
| Rated release current | 10 A |
| Rated uninterrupted current | 160 A |
| Number of poles | 4 |
| Trip unit | Ekip DIP LSI |
| Release technology | Solid-state electronic |
| Protection functions | Long-time, short-time and instantaneous |
| Short-circuit setting range | 1–10 × In |
| Rated operational voltage | up to 690 V AC |
| Ultimate breaking capacity Icu at 230 V AC | 200 kA |
| Ultimate breaking capacity Icu at 240 V AC | 200 kA |
| Ultimate breaking capacity Icu at 380 V AC | 150 kA |
| Ultimate breaking capacity Icu at 415 V AC | 150 kA |
| Ultimate breaking capacity Icu at 440 V AC | 150 kA |
| Ultimate breaking capacity Icu at 500 V AC | 70 kA |
| Ultimate breaking capacity Icu at 525 V AC | 50 kA |
| Ultimate breaking capacity Icu at 690 V AC | 20 kA |
| Mounting type | Fixed |
| Terminal arrangement | Front terminals |
| Terminal type | Bolt |
| Terminal tightening torque | 6 N·m |
| Standard | IEC 60947-2 |
| Product net width | 120 mm |
| Product net height | 130 mm |
| Product net depth | 82.5 mm |
| Product net weight | 1.5 kg |
| EAN | 8015644019129 |
| Customs tariff number | 85362090 |
The ABB 1SDA068016R1 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overload and short-circuit faults using an Ekip LSI electronic trip unit.
The Ekip LSI electronic release fitted to this circuit breaker has a rated current of 10 A, while the XT2 frame has a rated uninterrupted current of 160 A.
The Ekip DIP LSI electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection for accurate protection and coordination of low-voltage circuits.
The 1SDA068016R1 provides an ultimate short-circuit breaking capacity of 150 kA at 415 V AC and up to 200 kA at 230–240 V AC, making it suitable for installations with high prospective fault currents.
This model is a fixed four-pole circuit breaker with front bolt terminals, designed for installation within low-voltage switchboards, distribution panels and industrial electrical assemblies.
ABB SACE Tmax XT moulded case circuit breakers combine compact construction, advanced Ekip electronic protection and high short-circuit interruption performance to provide dependable protection for modern industrial, commercial and infrastructure electrical distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.