1SDA068012R1 ABB XT2V 160 Ekip I 63A 4-Pole Moulded Case Circuit Breaker

1SDA068012R1 ABB XT2V 160 Ekip I 63A 4-Pole Moulded Case Circuit Breaker

ABB 1SDA068012R1 XT2V 160 is a 63 A four-pole Tmax XT moulded case circuit breaker with an Ekip I electronic trip unit, adjustable instantaneous short-circuit protection, fixed mounting, front terminals and 150 kA ultimate breaking capacity at 380–415 V AC.

SKU: 1SDA068012R1MPN: 1SDA068012R1
Price
List Price £1,620.84 ex VAT
Your Price (ex VAT) Save 25%
£1,215.63 25% OFF
You save £405.21 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,215.63
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,215.63

Why Choose the ABB XT2V 160 Ekip I In=63A 4p F F Circuit Breaker?

The ABB 1SDA068012R1 XT2V 160 Ekip I In=63A 4p F F is a high-performance four-pole moulded case circuit breaker (MCCB) designed for short-circuit protection and isolation in demanding low-voltage electrical systems. Part of the ABB SACE Tmax XT range, it combines the compact XT2 160 frame with a solid-state electronic release and exceptionally high short-circuit breaking capability.

This fixed circuit breaker is equipped with an ABB Ekip I electronic trip unit rated at 63 A. The Ekip I release provides adjustable instantaneous short-circuit protection over a 1–10 × In range, allowing the protection threshold to be configured from 63–630 A. This makes it suitable for applications where rapid and dependable interruption of high fault currents is required.

The XT2V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, with performance extending to 20 kA at 690 V AC. Its four-pole configuration, fixed mounting and front terminals make the 1SDA068012R1 particularly suitable for three-phase and neutral distribution systems, switchboards and industrial electrical assemblies.

Key Advantages

  • High-performance ABB SACE Tmax XT moulded case circuit breaker.
  • 63 A Ekip I electronic release for precise short-circuit protection.
  • 150 kA ultimate breaking capacity at 380–415 V AC for installations with high prospective fault currents.
  • Adjustable instantaneous protection over a 1–10 × In range.
  • Four-pole configuration for three-phase and neutral electrical systems.
  • Operational capability up to 690 V AC.
  • Fixed installation with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT2 series.
  • XT2V 160 frame with V short-circuit performance level.
  • 63 A rated current.
  • Ekip I solid-state electronic trip unit.
  • Adjustable instantaneous short-circuit protection.
  • 63–630 A instantaneous protection range.
  • Four-pole configuration.
  • 150 kA ultimate breaking capacity at 380–415 V AC.
  • 20 kA ultimate breaking capacity at 690 V AC.
  • Rated voltage up to 690 V AC.
  • Fixed mounting with front terminals.
  • Designed in accordance with IEC requirements.

Reliable Electronic Short-Circuit Protection

Moulded case circuit breakers such as the ABB Tmax XT2 provide essential fault protection and isolation within low-voltage electrical distribution systems. The Ekip I solid-state release provides adjustable instantaneous short-circuit protection, allowing the trip threshold to be coordinated with the characteristics of the installation while enabling rapid interruption of severe fault currents.

The XT2V combines this electronic protection with exceptionally high short-circuit interruption capability in a compact four-pole MCCB format. Its fixed configuration and front terminals make it particularly suitable for low-voltage switchboards and distribution assemblies where dependable fault protection, high breaking performance and efficient use of panel space are required.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Main and sub-distribution switchboards.
  • Three-phase and neutral distribution circuits.
  • Manufacturing and production facilities.
  • Commercial electrical distribution systems.
  • Machinery and automation power circuits.
  • Infrastructure and building electrical systems.
  • Installations with high prospective short-circuit currents.

Technical Specifications

Series SACE Tmax XT2
ABB product group T-Max XT 250 Range
Order code 1SDA068012R1
Product type Moulded case circuit breaker (MCCB)
Frame size XT2 160
Frame rated uninterrupted current 160 A
Short-circuit performance level V
Rated current 63 A
Trip unit Ekip I
Release type Electronic / solid-state
Protection function Instantaneous short-circuit protection
Instantaneous protection adjustment 1–10 × In
Instantaneous protection range 63–630 A
Rated voltage 690 V AC
Rated impulse withstand voltage 8 kV
Rated frequency 50 / 60 Hz
Ultimate breaking capacity at 220–230 V AC 200 kA
Ultimate breaking capacity at 380–415 V AC 150 kA
Ultimate breaking capacity at 440 V AC 150 kA
Ultimate breaking capacity at 500 V AC 70 kA
Ultimate breaking capacity at 690 V AC 20 kA
Number of poles 4
Mounting type Fixed
Terminal arrangement Front terminals
Dimensions (H × W × D) 130 × 120 × 82.5 mm
Weight approx. 1.6 kg
Country of origin Italy
EAN 8015644019082

Frequently Asked Questions

What is the ABB 1SDA068012R1 used for?

The ABB 1SDA068012R1 is a four-pole moulded case circuit breaker designed to provide adjustable electronic short-circuit protection and circuit isolation in demanding low-voltage power distribution systems.

What is the rated current of the ABB XT2V 160 1SDA068012R1?

The circuit breaker has a rated current of 63 A and is equipped with an ABB Ekip I solid-state electronic trip unit.

What is the breaking capacity of this circuit breaker?

The XT2V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, with a breaking capacity of 20 kA at 690 V AC.

What protection does the Ekip I trip unit provide?

The Ekip I electronic trip unit provides adjustable instantaneous short-circuit protection over a 1–10 × In range, corresponding to 63–630 A for this 63 A release.

How is the ABB 1SDA068012R1 installed?

The breaker is a fixed four-pole unit with front terminals, designed for installation within low-voltage switchboards, distribution panels and industrial electrical assemblies.

Trusted ABB Protection for Critical Electrical Systems

ABB SACE Tmax XT moulded case circuit breakers provide compact and dependable protection for industrial and commercial electrical systems where electronic fault protection, high breaking performance and reliable circuit isolation are required.