1SDA067983R1 ABB XT2V 160 Ekip LSI In=63A 3p F F Moulded Case Circuit Breaker

1SDA067983R1 ABB XT2V 160 Ekip LSI In=63A 3p F F Moulded Case Circuit Breaker

ABB 1SDA067983R1 XT2V 160 Ekip LSI In=63A 3p F F is a 63 A three-pole fixed moulded case circuit breaker with an Ekip LSI solid-state electronic trip unit providing configurable overload and short-circuit protection for low-voltage AC distribution systems.

SKU: 1SDA067983R1MPN: 1SDA067983R1
Price
List Price £2,046.70 ex VAT
Your Price (ex VAT) Save 25%
£1,535.03 25% OFF
You save £511.68 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,535.03
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,535.03

Why Choose the ABB XT2V 160 Ekip LSI In=63A 3p F F Circuit Breaker?

The ABB XT2V 160 Ekip LSI In=63A 3p F F, order code 1SDA067983R1, is a high-performance three-pole moulded case circuit breaker (MCCB) designed for configurable protection of low-voltage AC power distribution systems. As part of the ABB SACE Tmax XT series, it combines the compact XT2 frame with an Ekip LSI solid-state electronic trip unit and the very high short-circuit performance of the XT2V configuration.

This circuit breaker is equipped with an Ekip LSI electronic release rated at 63 A. Its LSI protection functions provide long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection, allowing coordinated protection of conductors, feeders and electrical equipment in demanding industrial and commercial distribution systems.

The XT2V 160 Ekip LSI In=63A is a fixed three-pole circuit breaker with front terminals for straightforward integration into switchboards and distribution panels. It is rated for operation up to 690 V AC, while the XT2V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 415 V AC, making it suitable for installations with high prospective fault currents.

Key Advantages

  • Compact three-pole moulded case circuit breaker for low-voltage distribution.
  • 63 A rated current with solid-state electronic protection.
  • Ekip LSI trip unit provides long-time, short-time and instantaneous protection.
  • Electronic protection supports effective selectivity and circuit coordination.
  • High 150 kA ultimate breaking capacity at 415 V AC.
  • V-level interruption performance for installations with high prospective fault currents.
  • Rated for operation up to 690 V AC.
  • Fixed mounting with front terminals simplifies switchboard integration.

Key Features

  • ABB SACE Tmax XT2 series.
  • XT2V 160 configuration with V-level short-circuit performance.
  • Three-pole configuration.
  • 63 A rated current.
  • Ekip LSI solid-state electronic trip unit.
  • L function: long-time overload protection.
  • S function: short-time short-circuit protection.
  • I function: instantaneous short-circuit protection.
  • Instantaneous protection setting capability up to 10 × In.
  • 690 V AC rated voltage.
  • Fixed circuit-breaker construction with front terminal connections.

Configurable LSI Protection for Power Distribution

Electronic LSI moulded case circuit breakers combine several protection functions within a compact device. The ABB Ekip LSI release provides long-time overload protection together with short-time delayed and instantaneous short-circuit protection, allowing the protection characteristics to be coordinated with conductors, downstream devices and the electrical requirements of the installation.

The Tmax XT platform is designed for compact industrial switchboards and power distribution systems where dependable interruption of high prospective fault currents is essential. The XT2V configuration provides particularly high short-circuit performance, while its fixed front-connected construction supports efficient integration into switchboards, control panels and OEM electrical assemblies.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Electrical switchboards and distribution panels.
  • Feeder and branch-circuit protection.
  • Circuits requiring configurable LSI electronic protection.
  • Machinery and automation distribution panels.
  • Commercial and industrial building services.
  • OEM electrical equipment and panel building.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA067983R1
Product type Moulded case circuit breaker
Frame size XT2
Short-circuit performance level V
Number of poles 3
Rated current (In) 63 A
Frame current 160 A
Trip unit Ekip LSI
Release technology Solid-state electronic
Protection functions Long-time, short-time and instantaneous
Long-time function (L) Overload protection
Short-time function (S) Short-circuit protection with time delay
Instantaneous function (I) Instantaneous short-circuit protection
Instantaneous protection range up to 10 × In
Rated voltage 690 V AC
Rated frequency 50 / 60 Hz
Ultimate breaking capacity (Icu) at 415 V AC 150 kA
Mounting Fixed
Terminal connection Front
Net weight approx. 1.22 kg
EAN 8015644018795
Country of origin Italy
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA067983R1 used for?

The ABB 1SDA067983R1 is a three-pole moulded case circuit breaker designed to provide configurable electronic overload and short-circuit protection in low-voltage AC power distribution systems.

What current rating does the XT2V 160 Ekip LSI have?

The circuit breaker is fitted with a 63 A Ekip LSI electronic trip unit and uses the compact ABB XT2 160 frame.

What protection functions does the Ekip LSI trip unit provide?

The Ekip LSI trip unit provides long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection for coordinated electrical distribution protection.

What is the breaking capacity of the ABB XT2V 160?

The XT2V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 415 V AC, making it suitable for installations with high prospective fault currents.

How is the ABB 1SDA067983R1 installed?

The XT2V 160 Ekip LSI In=63A 3p F F is a fixed three-pole circuit breaker with front terminals, designed for integration into electrical switchboards, distribution panels and industrial equipment.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely used by panel builders, electrical engineers and industrial operators for compact, configurable and dependable protection of low-voltage electrical distribution systems.