ABB 1SDA067965R1 XT2L 160 is a four-pole Tmax XT moulded case circuit breaker with a 10 A Ekip LSIG electronic trip unit, integrated earth-fault protection and 120 kA ultimate breaking capacity at 400 V AC.

SKU: 1SDA067965R1MPN: 1SDA067965R1
Price
List Price £1,804.44 ex VAT
Your Price (ex VAT) Save 25%
£1,353.33 25% OFF
You save £451.11 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,353.33
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,353.33

Why Choose the ABB XT2L 160 Ekip LSIG In=10A 4p F F Circuit Breaker?

The ABB 1SDA067965R1 XT2L 160 Ekip LSIG In=10A 4p F F is a high-performance four-pole moulded case circuit breaker (MCCB) designed for comprehensive protection and isolation in industrial and commercial low-voltage power distribution systems. As part of the advanced ABB SACE Tmax XT range, it combines the compact XT2 160 frame with electronic protection and high short-circuit breaking capability.

This fixed circuit breaker is equipped with an ABB Ekip LSIG electronic trip unit rated at 10 A. The LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, delivering comprehensive electronic protection for critical distribution circuits. Its overload release setting is adjustable from 4–10 A, while both short-time delayed and instantaneous short-circuit settings cover 10–100 A.

The XT2L performance level provides an ultimate short-circuit breaking capacity of 120 kA at 400 V AC. With a rated voltage range of 220–690 V AC, four-pole configuration, fixed mounting and front terminals, the 1SDA067965R1 is well suited to switchboards and distribution systems requiring precise electronic protection, integrated earth-fault protection and high fault-clearing capability.

Key Advantages

  • Compact ABB SACE Tmax XT moulded case circuit breaker for demanding power distribution applications.
  • 10 A Ekip LSIG electronic trip unit for comprehensive circuit protection.
  • 120 kA ultimate breaking capacity at 400 V AC for high prospective fault currents.
  • Long-time, short-time, instantaneous and earth-fault protection.
  • Adjustable 4–10 A overload release setting.
  • Adjustable 10–100 A short-circuit protection settings.
  • Four-pole configuration for three-phase and neutral distribution systems.
  • Fixed installation with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT2 series.
  • XT2L 160 frame with L short-circuit performance level.
  • 10 A rated Ekip LSIG trip unit.
  • Electronic long-time overload protection.
  • Electronic short-time short-circuit protection.
  • Electronic instantaneous short-circuit protection.
  • Integrated electronic earth-fault protection.
  • 4–10 A adjustable overload setting.
  • 10–100 A short-time and instantaneous short-circuit settings.
  • Four-pole configuration.
  • 120 kA ultimate breaking capacity at 400 V AC.
  • Rated voltage range of 220–690 V AC.
  • Fixed mounting with front terminals.

Comprehensive LSIG Protection for Power Distribution

Moulded case circuit breakers such as the ABB Tmax XT2 protect electrical circuits and connected equipment against potentially damaging overloads, short circuits and earth faults. The Ekip LSIG electronic release provides four principal protection functions, allowing the breaker to respond appropriately to long-duration overloads, delayed short-circuit conditions, severe instantaneous faults and earth-fault currents.

The XT2L combines this comprehensive electronic protection with high short-circuit interruption capability in a compact four-pole MCCB format. Its integrated earth-fault protection, configurable trip characteristics, fixed configuration and front terminals make it particularly suitable for low-voltage switchboards where dependable protection, coordination and efficient use of panel space are required.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Main and sub-distribution switchboards.
  • Manufacturing and production facilities.
  • Commercial electrical distribution systems.
  • Machinery and automation power circuits.
  • Infrastructure and building electrical systems.
  • Four-pole circuits requiring integrated earth-fault protection.

Technical Specifications

Series SACE Tmax XT2
ABB product group T-Max XT 250 Range
Order code 1SDA067965R1
Product type Moulded case circuit breaker (MCCB)
Frame size XT2 160
Short-circuit performance level L
Trip unit rated current 10 A
Rated uninterrupted current 160 A
Trip unit Ekip LSIG
Release type Electronic / solid-state
Protection functions Long-time, short-time, instantaneous and earth-fault (LSIG)
Overload release setting 4–10 A
Short-time delayed short-circuit setting 10–100 A
Instantaneous short-circuit setting 10–100 A
Integrated earth-fault protection Yes
Rated voltage 220–690 V AC
Rated frequency 50 / 60 Hz
Ultimate breaking capacity at 400 V AC 120 kA
Number of poles 4
Mounting type Fixed
Terminal arrangement Front terminals
Motor operator Optional
Electrical durability 8,000 cycles
Mechanical durability 25,000 cycles
Dimensions (H × W × D) 130 × 120 × 82.5 mm
Weight approx. 1.5 kg

Frequently Asked Questions

What is the ABB 1SDA067965R1 used for?

The ABB 1SDA067965R1 is a four-pole moulded case circuit breaker designed to provide electronic overload, short-circuit and earth-fault protection in industrial and commercial low-voltage power distribution systems.

What is the rated current of the ABB XT2L 160 1SDA067965R1?

The circuit breaker is fitted with an Ekip LSIG trip unit rated at 10 A, with an adjustable overload release setting of 4–10 A.

What is the breaking capacity of this circuit breaker?

The XT2L performance level provides an ultimate short-circuit breaking capacity of 120 kA at 400 V AC.

What protection does the Ekip LSIG trip unit provide?

The Ekip LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection.

Does the ABB 1SDA067965R1 include earth-fault protection?

Yes. The Ekip LSIG trip unit includes integrated earth-fault protection, in addition to overload and short-circuit protection functions.