1SDA067947R1 ABB XT2L 160 Ekip LS/I 10A 4-Pole Moulded Case Circuit Breaker

1SDA067947R1 ABB XT2L 160 Ekip LS/I 10A 4-Pole Moulded Case Circuit Breaker

ABB 1SDA067947R1 XT2L 160 is a four-pole Tmax XT moulded case circuit breaker with a 10 A Ekip LS/I electronic trip unit, adjustable overload and short-circuit protection, fixed mounting and 120 kA ultimate breaking capacity at 415 V AC.

SKU: 1SDA067947R1MPN: 1SDA067947R1
Price
List Price £969.04 ex VAT
Your Price (ex VAT) Save 25%
£726.78 25% OFF
You save £242.26 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £726.78
Trade pricing is personalised to your account

Manufacturer Lead Time

£726.78

Why Choose the ABB XT2L 160 Ekip LS/I In=10A 4p F F Circuit Breaker?

The ABB 1SDA067947R1 XT2L 160 Ekip LS/I In=10A 4p F F is a high-performance four-pole moulded case circuit breaker (MCCB) designed for reliable protection and isolation in industrial and commercial low-voltage power distribution systems. As part of the advanced ABB SACE Tmax XT range, it combines the compact XT2 160 frame with an electronic trip unit and high short-circuit breaking performance.

This fixed circuit breaker is equipped with an ABB Ekip LS/I electronic trip unit rated at 10 A. The electronic release provides long-time overload protection together with short-circuit protection, offering an adjustable overload setting of 4–10 A and a short-circuit protection threshold of 10–100 A. This allows protection characteristics to be configured for the requirements of the connected circuit.

The XT2L performance level provides an ultimate short-circuit breaking capacity of 120 kA at 415 V AC. With a four-pole configuration, rated operational voltage up to 690 V AC, fixed mounting and front terminals, the 1SDA067947R1 is well suited to switchboards and distribution systems requiring precise electronic protection and high fault-clearing capability.

Key Advantages

  • Compact ABB SACE Tmax XT moulded case circuit breaker for power distribution.
  • 10 A Ekip LS/I electronic trip unit for configurable circuit protection.
  • 120 kA ultimate breaking capacity at 415 V AC for demanding fault conditions.
  • Adjustable 4–10 A overload protection range.
  • Adjustable 10–100 A short-circuit protection threshold.
  • Four-pole configuration for three-phase and neutral distribution systems.
  • Fixed installation with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT2 series.
  • XT2L 160 frame with L short-circuit performance level.
  • 10 A rated Ekip LS/I trip unit.
  • Electronic long-time overload protection.
  • Electronic short-circuit protection.
  • 4–10 A adjustable overload setting.
  • 10–100 A adjustable short-circuit setting.
  • Four-pole configuration.
  • 120 kA ultimate breaking capacity at 415 V AC.
  • Rated operational voltage up to 690 V AC.
  • Fixed mounting with front terminals.

Advanced Electronic Protection for Power Distribution

Moulded case circuit breakers such as the ABB Tmax XT2 protect electrical circuits and connected equipment against potentially damaging overload and short-circuit currents. The Ekip LS/I electronic release provides configurable long-time overload and short-circuit protection, allowing the breaker characteristics to be matched more closely to the requirements of the protected circuit.

The XT2L combines this electronic protection with high short-circuit interruption capability in a compact four-pole MCCB format. Its fixed configuration and front terminals make it particularly suitable for low-voltage switchboards and distribution assemblies where dependable protection, high fault-clearing performance and efficient use of panel space are required.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Main and sub-distribution switchboards.
  • Manufacturing and production facilities.
  • Commercial electrical distribution systems.
  • Machinery and automation power circuits.
  • Infrastructure and building electrical systems.
  • Four-pole circuits requiring electronic overload and short-circuit protection.

Technical Specifications

Series SACE Tmax XT2
ABB product group T-Max XT 250 Range
Order code 1SDA067947R1
Product type Moulded case circuit breaker (MCCB)
Frame size XT2 160
Short-circuit performance level L
Trip unit rated current 10 A
Trip unit Ekip LS/I
Release type Electronic / solid-state
Overload setting 4–10 A
Short-circuit setting 10–100 A
Rated operational voltage up to 690 V AC
Rated impulse withstand voltage 8 kV
Rated frequency 50 / 60 Hz
Ultimate breaking capacity at 415 V AC 120 kA
Ultimate breaking capacity at 440 V AC 100 kA
Ultimate breaking capacity at 500 V AC 60 kA
Ultimate breaking capacity at 690 V AC 18 kA
Number of poles 4
Mounting type Fixed
Terminal arrangement Front terminals
Terminal type Bolt
Standard IEC 60947-2
Dimensions (H × W × D) 130 × 120 × 82.5 mm
Weight approx. 1.5 kg
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA067947R1 used for?

The ABB 1SDA067947R1 is a four-pole moulded case circuit breaker designed to provide electronic overload and short-circuit protection in industrial and commercial low-voltage power distribution systems.

What is the rated current of the ABB XT2L 160 1SDA067947R1?

The circuit breaker is fitted with an Ekip LS/I trip unit rated at 10 A, with an adjustable overload setting of 4–10 A.

What is the breaking capacity of this circuit breaker?

The XT2L performance level provides an ultimate short-circuit breaking capacity of 120 kA at 415 V AC.

What protection does the Ekip LS/I trip unit provide?

The Ekip LS/I electronic trip unit provides long-time overload and short-circuit protection, with a 4–10 A overload setting and a 10–100 A short-circuit setting.

How is the ABB 1SDA067947R1 installed?

The breaker is a fixed four-pole unit with front terminals, designed for installation within low-voltage switchboards, distribution panels and industrial electrical assemblies.

Trusted ABB Protection for Critical Electrical Systems

ABB SACE Tmax XT moulded case circuit breakers are widely used in industrial and commercial power distribution systems where compact installation, configurable electronic protection and high short-circuit performance are required.