1SDA067932R1 ABB XT2L 160 Ekip LSIG In=100A 3P Fixed Circuit Breaker

1SDA067932R1 ABB XT2L 160 Ekip LSIG In=100A 3P Fixed Circuit Breaker

ABB 1SDA067932R1 is an XT2L 160 three-pole fixed moulded case circuit breaker with front terminals, a 100 A rated current and an Ekip DIP LSIG electronic trip unit for comprehensive low-voltage power distribution protection.

SKU: 1SDA067932R1MPN: 1SDA067932R1
Price
List Price £1,820.44 ex VAT
Your Price (ex VAT) Save 25%
£1,365.33 25% OFF
You save £455.11 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,365.33
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,365.33

Why Choose the ABB XT2L 160 Ekip LSIG In=100A 3P Fixed Circuit Breaker?

The ABB XT2L 160 Ekip LSIG In=100A 3P F F is a high-performance moulded case circuit breaker (MCCB) designed for comprehensive protection of low-voltage power distribution circuits. As part of the ABB SACE Tmax XT2 series, it combines the compact XT2 frame with an Ekip DIP LSIG solid-state electronic trip unit for accurate protection in demanding industrial and commercial electrical installations.

This XT2L configuration features a fixed three-pole construction with front terminals, providing a practical arrangement for integration into switchboards, distribution panels and electrical control assemblies. Its L short-circuit performance level provides an ultimate short-circuit breaking capacity of 120 kA at 415 V AC, delivering robust fault-clearing capability for demanding low-voltage networks.

With a rated current of 100 A and an Ekip DIP LSIG electronic trip unit, the breaker provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. Its adjustable overload release range of 40–100 A, electronic protection technology and rated operational voltage up to 690 V AC make it suitable for modern distribution systems requiring comprehensive and configurable circuit protection.

Key Advantages

  • High-performance ABB SACE Tmax XT2L moulded case circuit breaker.
  • 100 A rated current for industrial and commercial power distribution.
  • Ekip DIP LSIG electronic trip unit provides comprehensive circuit protection.
  • Long-time, short-time, instantaneous and earth-fault protection functions.
  • High 120 kA ultimate breaking capacity at 415 V AC.
  • Three-pole fixed construction with front terminals for efficient switchboard integration.

Key Features

  • ABB SACE Tmax XT2 series.
  • XT2L 160 frame configuration.
  • 100 A rated current.
  • 40–100 A overload release adjustment range.
  • Ekip DIP LSIG solid-state electronic protection release.
  • LSIG protection functions for overload, short-circuit and earth-fault protection.
  • Three-pole configuration.
  • Fixed mounting arrangement.
  • Front terminal connections.
  • Rated operational voltage up to 690 V AC.

Comprehensive Electronic Protection for Power Distribution

Moulded case circuit breakers such as the ABB Tmax XT2 protect electrical distribution systems by automatically disconnecting circuits when damaging overload, short-circuit or earth-fault conditions occur. The Ekip LSIG electronic trip unit provides long-time overload protection, short-time short-circuit protection, instantaneous short-circuit protection and ground-fault protection for comprehensive system protection.

The XT2L combines configurable electronic protection with high short-circuit interruption performance in a compact breaker frame. Its fixed three-pole construction and front terminal arrangement make it well suited to industrial switchboards, commercial distribution panels and OEM electrical assemblies requiring accurate protection, reliable fault interruption and efficient panel integration.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Commercial electrical distribution panels.
  • Feeder and branch circuit protection.
  • Circuits requiring integrated earth-fault protection.
  • Industrial machinery and automation panels.
  • Infrastructure and building electrical distribution systems.
  • OEM switchgear and electrical distribution assemblies.

Technical Specifications

Series SACE Tmax XT2
ABB order code 1SDA067932R1
Product type Moulded case circuit breaker
Frame size XT2
Rated uninterrupted current (Iu) 160 A
Rated current (In) 100 A
Protection release Ekip DIP LSIG solid-state electronic
Protection functions L, S, I and G
Overload release adjustment 40–100 A
Short-time short-circuit adjustment 100–1000 A
Instantaneous short-circuit adjustment 100–1000 A
Ground-fault protection Integrated
Number of poles 3
Mounting Fixed
Terminal arrangement Front terminals
Current type AC
Rated operational voltage 220–690 V AC
Rated impulse withstand voltage (Uimp) 8 kV
Rated frequency 50 / 60 Hz
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 120 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 18 kA
Short-circuit performance level L
Standard IEC 60947-2
Dimensions (H × W × D) 130 × 90 × 82.5 mm
Product net weight approx. 1.22 kg
EAN 8015644018283

Frequently Asked Questions

What is the ABB 1SDA067932R1?

The ABB 1SDA067932R1 is an XT2L 160 three-pole fixed moulded case circuit breaker with front terminals, a 100 A rated current and an Ekip DIP LSIG electronic protection release.

What is the rated current of this XT2L circuit breaker?

This XT2L configuration has a rated current of 100 A, with an overload release adjustment range of 40–100 A.

What does LSIG mean on the Ekip trip unit?

LSIG identifies long-time overload protection, short-time short-circuit protection, instantaneous short-circuit protection and ground or earth-fault protection.

Does the ABB 1SDA067932R1 provide earth-fault protection?

Yes. The G protection function of the Ekip LSIG electronic trip unit provides integrated earth-fault protection.

What is the breaking capacity of the ABB XT2L 160?

This XT2L configuration provides an ultimate short-circuit breaking capacity of 120 kA at 415 V AC.

How is the ABB 1SDA067932R1 installed?

The breaker is supplied in a fixed three-pole configuration with front terminals for integration into suitable low-voltage switchboards, distribution panels and electrical assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely used by panel builders, electrical engineers and industrial operators for dependable electronic circuit protection, compact switchboard integration and high-performance low-voltage power distribution.