1SDA067924R1 ABB XT2L 160 Ekip LSI 10A 3-Pole Moulded Case Circuit Breaker

1SDA067924R1 ABB XT2L 160 Ekip LSI 10A 3-Pole Moulded Case Circuit Breaker

ABB 1SDA067924R1 XT2L 160 is a three-pole Tmax XT moulded case circuit breaker with a 10 A Ekip LSI electronic trip unit, fixed mounting, front terminals and 120 kA ultimate breaking capacity at 400–415 V AC.

SKU: 1SDA067924R1MPN: 1SDA067924R1
Price
List Price £1,334.16 ex VAT
Your Price (ex VAT) Save 25%
£1,000.62 25% OFF
You save £333.54 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,000.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,000.62

Why Choose the ABB XT2L 160 Ekip LSI In=10A 3p F F Circuit Breaker?

The ABB 1SDA067924R1 XT2L 160 Ekip LSI In=10A 3p F F is a high-performance three-pole moulded case circuit breaker (MCCB) designed for dependable protection and isolation in industrial and commercial low-voltage power distribution systems. As part of the ABB SACE Tmax XT range, it combines the compact XT2 160 frame with an electronic trip unit and high short-circuit breaking performance.

This fixed circuit breaker is equipped with an ABB Ekip LSI electronic trip unit, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection. With a rated trip-unit current of 10 A, the breaker is particularly suited to lower-current circuits that require the robust construction and high fault-clearing capability of the Tmax XT2 platform.

The XT2L performance level provides an ultimate short-circuit breaking capacity of 120 kA at 400–415 V AC. Its three-pole configuration, fixed mounting and front terminals make the 1SDA067924R1 suitable for integration into switchboards, distribution panels, machinery and other electrical installations where precise electronic protection and high breaking performance are required.

Key Advantages

  • Compact ABB SACE Tmax XT moulded case circuit breaker for power distribution.
  • 10 A Ekip LSI electronic trip unit for comprehensive circuit protection.
  • 120 kA ultimate breaking capacity at 400–415 V AC for demanding fault conditions.
  • Long-time, short-time and instantaneous LSI protection functions.
  • Three-pole configuration for three-phase electrical systems.
  • Fixed installation with front terminals for convenient switchboard integration.

Key Features

  • ABB SACE Tmax XT2 series.
  • XT2L 160 frame with L breaking-performance level.
  • 10 A rated Ekip LSI trip unit.
  • Electronic long-time overload protection.
  • Electronic short-time short-circuit protection.
  • Electronic instantaneous short-circuit protection.
  • Three-pole configuration.
  • 120 kA ultimate breaking capacity at 400–415 V AC.
  • Rated operational voltage up to 690 V AC.
  • Fixed mounting with front terminals.

Advanced Electronic Protection for Power Distribution

Moulded case circuit breakers such as the ABB Tmax XT2 protect electrical circuits and connected equipment against potentially damaging overcurrents and short circuits. The Ekip LSI electronic release provides separate long-time, short-time and instantaneous protection functions, enabling more precise circuit protection than a basic instantaneous-only release.

The XT2L version combines this electronic protection with high short-circuit interruption capability in a compact frame. Its fixed configuration and front terminals make it well suited to low-voltage switchboards and distribution assemblies where dependable fault protection, selective coordination and efficient use of panel space are important.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Main and sub-distribution switchboards.
  • Manufacturing and production equipment.
  • Commercial electrical distribution systems.
  • Machinery and automation power circuits.
  • Infrastructure and building electrical systems.
  • Low-current circuits requiring high short-circuit breaking capability.

Technical Specifications

Series SACE Tmax XT2
ABB product group T-Max XT 250 Range
Order code 1SDA067924R1
Product type Moulded case circuit breaker (MCCB)
Frame size XT2 160
Short-circuit performance level L
Trip unit rated current 10 A
Trip unit Ekip LSI
Release type Electronic / solid-state
Protection functions Long-time, short-time and instantaneous (LSI)
Overload release setting 4–10 A
Short-time short-circuit setting 10–100 A
Instantaneous short-circuit setting 10–100 A
Rated operational voltage up to 690 V AC
Ultimate breaking capacity at 400–415 V AC 120 kA
Number of poles 3
Mounting type Fixed
Terminal arrangement Front terminals
Integrated earth-fault protection No
Motor operator Optional
Net weight approx. 1.2 kg
GTIN / EAN 8015644018207

Frequently Asked Questions

What is the ABB 1SDA067924R1 used for?

The ABB 1SDA067924R1 is a three-pole moulded case circuit breaker designed to provide electronic overload and short-circuit protection in industrial and commercial low-voltage power distribution systems.

What is the rated current of the ABB XT2L 160 1SDA067924R1?

The circuit breaker is fitted with an Ekip LSI trip unit rated at 10 A, providing adjustable electronic protection for lower-current circuits.

What is the breaking capacity of this circuit breaker?

The XT2L performance level provides an ultimate short-circuit breaking capacity of 120 kA at 400–415 V AC.

What protection does the Ekip LSI trip unit provide?

The Ekip LSI electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

How is the ABB 1SDA067924R1 installed?

The breaker is a fixed three-pole unit with front terminals, designed for installation within low-voltage switchboards, distribution panels and electrical assemblies.

Trusted ABB Protection for Critical Electrical Systems

ABB SACE Tmax XT moulded case circuit breakers are widely used in industrial and commercial power distribution systems where compact installation, configurable electronic protection and high short-circuit performance are required.