ABB XT2H 160 4 pole High MCCB Electronic trip unit LS/I Ii=160A

ABB XT2H 160 4 pole High MCCB Electronic trip unit LS/I Ii=160A

ABB 1SDA067895R1 Tmax XT2H 160 moulded case circuit breaker with Ekip LS/I electronic trip unit, four poles, 160 A rated current and 70 kA breaking capacity.

SKU: 1SDA067895R1Alt SKU: XT2H 160 Ekip Dip LS/I In=160A 4pFF InN=100%MPN: 1SDA067895R1
Price
List Price £1,146.17 ex VAT
Your Price (ex VAT) Save 25%
£859.63 25% OFF
You save £286.54 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £859.63
Trade pricing is personalised to your account

Manufacturer Lead Time

£859.63

Why Choose the ABB 1SDA067895R1 Tmax XT2H 160 Circuit Breaker?

The ABB 1SDA067895R1 is a premium Tmax XT2H 160 moulded case circuit breaker (MCCB) engineered to provide dependable protection for industrial and commercial low-voltage electrical distribution systems. As part of the renowned ABB SACE Tmax XT range, it delivers excellent protection against overloads and short circuits while maintaining a compact, panel-friendly design.

Featuring an advanced Ekip LS/I electronic trip unit, this circuit breaker provides accurate long-time and instantaneous protection to maximise system reliability. The fully rated neutral design makes it particularly suitable for modern three-phase installations where neutral conductor protection is required.

With a rated current of 160 A, a 70 kA breaking capacity at 415 V AC and a four-pole fixed configuration, the ABB 1SDA067895R1 is ideal for demanding electrical installations, switchboards and OEM equipment where high fault protection and operational reliability are essential.

Key Advantages

  • High-performance ABB Tmax XT2H 160 moulded case circuit breaker.
  • 160 A rated current for industrial and commercial power distribution.
  • 70 kA breaking capacity at 415 V AC.
  • Advanced Ekip LS/I electronic trip unit.
  • Fully rated neutral (100%) four-pole configuration.
  • Compact fixed design with front terminals for straightforward installation.

Key Features

  • ABB SACE Tmax XT series.
  • XT2H 160 frame size.
  • 160 A rated current.
  • Four-pole moulded case circuit breaker.
  • Ekip LS/I electronic release.
  • Long-time and instantaneous protection functions.
  • Front terminal connections.
  • Fixed mounting configuration.

Reliable Protection for Critical Power Distribution

The ABB Tmax XT2H series is designed to protect low-voltage electrical installations against overload and short-circuit faults. The electronic trip unit provides precise protection characteristics, helping to reduce downtime while protecting valuable electrical infrastructure and connected equipment.

Its compact dimensions, high interruption capacity and fully rated neutral configuration make the ABB 1SDA067895R1 an excellent choice for industrial switchboards, commercial buildings and OEM machinery requiring dependable circuit protection.

Typical Applications

  • Industrial switchboards.
  • Commercial electrical distribution systems.
  • Motor control centres.
  • OEM machinery and equipment.
  • Power distribution panels.
  • Critical infrastructure installations.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Trip Unit LS/I
Current 160 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 70 kA
Manufacturer ABB
Series SACE Tmax XT
Model XT2H 160 Ekip LS/I In=160A 4p F F InN=100%
Product ID 1SDA067895R1
Product type Moulded case circuit breaker
Rated current 160 A
Number of poles 4-pole
Trip unit Ekip LS/I electronic release
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Breaking capacity (Icu) 70 kA at 415 V AC
Frequency 50 / 60 Hz
Mounting type Fixed
Terminal connection Front terminals
EAN 8015644017910
Dimensions (H × W × D) 130 × 120 × 82.5 mm
Weight Approx. 1.6 kg
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA067895R1 used for?

It protects low-voltage electrical systems against overloads and short circuits in industrial and commercial installations.

What is the rated current of this MCCB?

The ABB 1SDA067895R1 has a rated current of 160 A.

How many poles does this circuit breaker have?

This model features a four-pole fixed configuration with a fully rated neutral.

What trip unit is installed?

It is fitted with an Ekip LS/I electronic trip unit providing long-time and instantaneous protection.

Where is this MCCB typically installed?

It is commonly installed in switchboards, panelboards, motor control centres and industrial power distribution equipment.

Trusted by Electrical Professionals Worldwide

ABB Tmax XT moulded case circuit breakers are trusted worldwide for delivering dependable protection, high interrupting capacity and long service life in demanding industrial and commercial electrical installations.