ABB XT2S 160 4 pole Standard MCCB Adjustable Thermal/Fixed Magnetic Release In=63A Ii=200A

ABB XT2S 160 4 pole Standard MCCB Adjustable Thermal/Fixed Magnetic Release In=63A Ii=200A

ABB XT2S 160 TMG 63-200 4P F F moulded case circuit breaker with thermomagnetic trip unit, 63 A rated current and four-pole fixed configuration for industrial power distribution.

SKU: 1SDA067755R1Alt SKU: XT2S 160 TMG 63-200 4p F FMPN: 1SDA067755R1
Price
List Price £504.72 ex VAT
Your Price (ex VAT) Save 25%
£378.54 25% OFF
You save £126.18 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £378.54
Trade pricing is personalised to your account

Manufacturer Lead Time

£378.54

Why Choose the ABB 1SDA067755R1 XT2S 160 TMG 63-200 4P MCCB?

The ABB 1SDA067755R1 is a high-performance SACE Tmax XT2S moulded case circuit breaker (MCCB) designed to provide dependable protection for low voltage electrical distribution systems. Featuring a fixed four-pole configuration with a thermomagnetic (TMG) trip unit, it delivers reliable protection against overloads and short circuits in industrial and commercial installations.

As part of the trusted ABB SACE Tmax XT series, this MCCB combines excellent breaking performance with a compact design, making it ideal for switchboards, control panels, OEM equipment and generator protection applications. Its front terminal arrangement simplifies installation while maintaining excellent electrical performance.

With a 63 A rated current, 690 V AC operating voltage and a 160 A frame size, the ABB 1SDA067755R1 offers dependable circuit protection for demanding power distribution systems where safety, reliability and long service life are essential.

Key Advantages

  • Compact ABB SACE Tmax XT2S moulded case circuit breaker.
  • 63 A rated current with thermomagnetic protection.
  • Four-pole fixed configuration for comprehensive circuit isolation.
  • High breaking capacity for demanding industrial installations.
  • Suitable for generator, distribution and machinery protection.
  • Front terminal design enables straightforward installation.

Key Features

  • Manufacturer: ABB
  • SACE Tmax XT2S series.
  • Model: XT2S 160 TMG 63-200 4P F F.
  • 63 A rated current (In).
  • 160 A frame size.
  • Four-pole fixed construction.
  • Thermomagnetic (TMG) trip unit.
  • Front terminal connections.
  • Suitable for AC and DC applications.
  • Designed in accordance with IEC 60947-2.

Reliable Protection for Low Voltage Power Distribution

The ABB XT2S range has been engineered to provide dependable protection for electrical distribution systems by automatically disconnecting power during overload or short circuit conditions. This helps safeguard cables, motors, switchgear and connected equipment while improving overall system reliability.

Its compact footprint, robust mechanical construction and high interrupting capability make the XT2S series suitable for industrial machinery, commercial installations, panel building and generator protection where dependable operation is essential.

Typical Applications

  • Industrial switchboards.
  • Power distribution panels.
  • Generator protection systems.
  • Motor control centres.
  • OEM machinery.
  • Commercial electrical installations.
  • Industrial automation systems.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Generator protection
Current 63 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 50 kA
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax XT
Model XT2S 160 TMG 63-200 4P F F
Product code 1SDA067755R1
Product type Moulded Case Circuit Breaker (MCCB)
Frame size XT2 160
Rated current (In) 63 A
Rated uninterrupted current (Iu) 160 A
Number of poles 4
Trip unit Thermomagnetic (TMG)
Rated operational voltage Up to 690 V AC / 500 V DC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Breaking capacity Up to 50 kA at 415 V AC
Frequency 50 / 60 Hz
Terminal type Front terminals
Mounting Fixed
Standards IEC 60947-2
Dimensions (H × W × D) Approx. 130 × 120 × 82.5 mm
Weight Approx. 1.45 kg
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA067755R1 used for?

It is a moulded case circuit breaker designed to protect low voltage electrical distribution systems against overloads and short circuits.

How many poles does this circuit breaker have?

This model features a four-pole (4P) fixed configuration.

What is the rated current?

The breaker has a 63 A rated current (In) with a 160 A frame size.

What type of trip unit is fitted?

The breaker is equipped with an integrated thermomagnetic (TMG) trip unit providing overload and magnetic short circuit protection.

Where is this MCCB commonly installed?

It is commonly installed in switchboards, distribution panels, industrial machinery, generator systems and commercial electrical installations.