ABB 1SDA067714R1 XT2V 160 is a 125 A four-pole Tmax XT moulded case circuit breaker with a TMA thermomagnetic trip unit, fully rated neutral and 150 kA breaking capacity at 415 V AC.
£948.62
The ABB 1SDA067714R1 XT2V 160 TMA 125-1250 4p F F InN=100% is a high-performance four-pole moulded case circuit breaker (MCCB) designed for protection and isolation in industrial and commercial low-voltage power distribution systems. As part of the ABB SACE Tmax XT range, it combines compact dimensions with high short-circuit breaking performance for demanding electrical installations.
This fixed circuit breaker is equipped with an ABB TMA thermomagnetic trip unit providing overload and short-circuit protection. Its rated current is 125 A, while the instantaneous magnetic protection setting covers 625–1250 A. The four-pole design incorporates a fully rated neutral at 100%, providing protection and switching across all four conductors.
The XT2V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 415 V AC, making the breaker suitable for installations with high prospective fault currents. With fixed mounting, front terminals and a rated operational voltage of up to 690 V AC, the 1SDA067714R1 provides dependable circuit protection in switchboards, distribution panels and industrial electrical systems.
Moulded case circuit breakers such as the ABB Tmax XT2 protect electrical circuits and connected equipment against overloads and short circuits. The thermomagnetic TMA release combines thermal overload protection with rapid magnetic operation during high-current fault conditions, helping minimise damage to cables, switchgear and downstream equipment.
The XT2V version is engineered for installations requiring particularly high short-circuit interruption capability. Its compact frame, fixed configuration and front terminals make it well suited to switchboards and distribution assemblies where dependable protection, high fault-clearing performance and efficient use of panel space are required.
| Series | SACE Tmax XT2 |
|---|---|
| ABB product group | T-Max XT 250 Range |
| Order code | 1SDA067714R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame size | XT2 160 |
| Rated current | 125 A |
| Rated operational voltage | up to 690 V AC |
| Ultimate breaking capacity (415 V AC) | 150 kA |
| Trip unit | TMA thermomagnetic |
| Instantaneous magnetic setting | 625–1250 A |
| Number of poles | 4 |
| Neutral rating | 100% fully rated neutral |
| Mounting type | Fixed |
| Terminal arrangement | Front terminals |
| Application | Power distribution |
| Electrical durability | 8,000 cycles |
| Mechanical durability | 25,000 cycles |
| Dimensions (W × H × D) | 120 × 130 × 82.5 mm |
| Net weight | 1.6 kg |
| EAN | 8015644016104 |
The ABB 1SDA067714R1 is a four-pole moulded case circuit breaker designed to provide overload and short-circuit protection in industrial and commercial low-voltage power distribution systems.
The circuit breaker has a rated current of 125 A and uses a TMA thermomagnetic trip unit.
The XT2V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 415 V AC.
InN=100% indicates that the fourth pole has a fully rated neutral at 100% of the breaker rated current.
The breaker uses an ABB TMA thermomagnetic trip unit with a 125 A rated current and an instantaneous magnetic protection setting of 625–1250 A.
ABB SACE Tmax XT moulded case circuit breakers are widely used in industrial and commercial power distribution systems where compact installation, dependable circuit protection and high short-circuit performance are required.