1SDA067712R1 ABB XT2V 160 TMA 125-1250 4P Fixed Circuit Breaker InN=50%

1SDA067712R1 ABB XT2V 160 TMA 125-1250 4P Fixed Circuit Breaker InN=50%

ABB 1SDA067712R1 is an XT2V 160 four-pole fixed moulded case circuit breaker with front terminals, a 125 A TMA thermomagnetic trip unit and a 50% neutral rating for low-voltage power distribution.

SKU: 1SDA067712R1MPN: 1SDA067712R1
Price
List Price £1,264.83 ex VAT
Your Price (ex VAT) Save 25%
£948.62 25% OFF
You save £316.21 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £948.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£948.62

Why Choose the ABB XT2V 160 TMA 125-1250 4P Fixed Circuit Breaker?

The ABB XT2V 160 TMA 125-1250 4P F F InN=50% is a high-performance moulded case circuit breaker (MCCB) designed for reliable protection of low-voltage power distribution circuits. As part of the ABB SACE Tmax XT2 series, it combines the compact XT2 160 frame with a TMA thermomagnetic trip unit for overload and short-circuit protection in demanding industrial and commercial electrical installations.

This XT2V configuration features a fixed four-pole construction with front terminals, providing a practical arrangement for integration into switchboards and distribution assemblies. The V performance level delivers an ultimate short-circuit breaking capacity of 150 kA at 415 V AC, making the breaker suitable for installations with high prospective fault currents.

With a rated current of 125 A and a TMA 125-1250 thermomagnetic trip unit, the breaker provides adjustable thermal overload protection together with adjustable magnetic short-circuit protection. This specific four-pole version has the neutral pole rated at 50% of the phase current (InN=50%), providing a configuration suited to four-wire distribution systems where a reduced neutral rating is appropriate.

Key Advantages

  • High-performance ABB SACE Tmax XT2V moulded case circuit breaker.
  • 125 A rated current for low-voltage power distribution applications.
  • TMA thermomagnetic trip unit provides overload and short-circuit protection.
  • High 150 kA ultimate breaking capacity at 415 V AC.
  • Four-pole configuration with 50% neutral rating for suitable four-wire systems.
  • Fixed mounting with front terminals supports straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT2 series.
  • XT2V 160 frame configuration.
  • 125 A rated current.
  • TMA 125-1250 thermomagnetic trip unit.
  • Adjustable thermal overload protection.
  • Adjustable magnetic short-circuit protection.
  • Four-pole configuration.
  • Neutral pole rated at 50% (InN=50%).
  • Fixed mounting arrangement.
  • Front terminal connections.

Reliable Circuit Protection for Power Distribution

Moulded case circuit breakers such as the ABB Tmax XT2 protect electrical distribution systems by automatically disconnecting circuits when overload or short-circuit conditions occur. The TMA thermomagnetic trip unit combines adjustable thermal overload protection with adjustable magnetic short-circuit protection, allowing the protective response to be matched to the requirements of the protected circuit.

The XT2V version is engineered for installations requiring high fault interruption performance within a compact breaker frame. This four-pole version incorporates a 50% neutral rating and is particularly suited to appropriate three-phase four-wire distribution systems, while its fixed construction and front terminals simplify integration into low-voltage switchboards and electrical assemblies.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Commercial electrical distribution systems.
  • Three-phase four-wire power distribution circuits.
  • Machinery and automation electrical panels.
  • Feeder and branch circuit protection.
  • Systems with high prospective short-circuit currents.
  • OEM switchgear and electrical distribution assemblies.

Technical Specifications

Series SACE Tmax XT2
ABB order code 1SDA067712R1
Product type Moulded case circuit breaker
Frame size XT2
Rated uninterrupted current (Iu) 160 A
Rated current (In) 125 A
Protection release TMA thermomagnetic
Trip unit designation TMA 125-1250
Thermal protection Adjustable
Magnetic protection Adjustable
Number of poles 4
Neutral rating 50% of phase current (InN=50%)
Mounting Fixed
Terminal arrangement Front terminals
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated frequency 50 / 60 Hz
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 150 kA
Short-circuit performance level V
Standard IEC 60947-2
EAN 8015644016081

Frequently Asked Questions

What is the ABB 1SDA067712R1?

The ABB 1SDA067712R1 is an XT2V 160 four-pole fixed moulded case circuit breaker with front terminals, a 125 A TMA 125-1250 thermomagnetic trip unit and a 50% neutral rating.

What is the rated current of this XT2V circuit breaker?

This XT2V configuration has a rated current of 125 A and uses the compact ABB XT2 160 frame.

What does TMA 125-1250 mean on this circuit breaker?

The TMA 125-1250 designation identifies the thermomagnetic trip unit fitted to the breaker, providing adjustable thermal overload protection and adjustable magnetic short-circuit protection for the 125 A configuration.

What does InN=50% mean on the ABB 1SDA067712R1?

InN=50% means the neutral pole is rated at 50% of the phase current, distinguishing this version from four-pole configurations with a full-rated neutral.

What is the breaking capacity of the ABB XT2V 160?

The XT2V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 415 V AC.

How is the ABB 1SDA067712R1 installed?

The circuit breaker is supplied in a fixed four-pole configuration with front terminals for integration into suitable low-voltage switchboards and electrical distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely used by panel builders, electrical engineers and industrial operators for dependable circuit protection, compact switchboard integration and high-performance low-voltage power distribution.