1SDA067677R1 ABB XT2V 160 TMD 5-50 3p F F Moulded-Case Circuit Breaker

1SDA067677R1 ABB XT2V 160 TMD 5-50 3p F F Moulded-Case Circuit Breaker

ABB 1SDA067677R1 XT2V 160 TMD 5-50 3p F F is a fixed three-pole moulded-case circuit breaker with front terminals, a 5 A TMD thermomagnetic trip unit, a 50 A magnetic short-circuit setting and a 150 kA-class ultimate short-circuit breaking capacity.

SKU: 1SDA067677R1MPN: 1SDA067677R1
Price
List Price £926.69 ex VAT
Your Price (ex VAT) Save 25%
£695.02 25% OFF
You save £231.67 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £695.02
Trade pricing is personalised to your account

Manufacturer Lead Time

£695.02

Why Choose the ABB XT2V 160 TMD 5-50 3p F F Circuit Breaker?

The ABB 1SDA067677R1 is an ABB SACE Tmax XT2V 160 three-pole moulded-case circuit breaker equipped with a TMD thermomagnetic trip unit. Rated at 5 A, it combines thermal overload protection with a 50 A magnetic short-circuit release for dependable protection of low-voltage electrical circuits.

The XT2V is the very-high-breaking-capacity version of the XT2 frame, with an ultimate short-circuit breaking capacity (Icu) class of 150 kA. This makes it particularly suitable for installations where high prospective fault currents require robust interruption capability from a compact moulded-case circuit breaker.

Configured as a fixed three-pole circuit breaker with front terminals, the 1SDA067677R1 is designed for straightforward integration into industrial and commercial distribution equipment. Its XT2 frame is rated at 160 A, while the fitted TMD release has a rated current of 5 A and a 50 A magnetic short-circuit setting.

Key Advantages

  • Complete ABB SACE Tmax XT2V moulded-case circuit breaker for low-voltage circuit protection.
  • 5 A TMD thermomagnetic trip unit provides overload and short-circuit protection.
  • 50 A magnetic short-circuit trip setting for rapid fault protection.
  • High 150 kA XT2V breaking-capacity class for demanding electrical installations.
  • Three-pole configuration suitable for three-phase circuits.
  • Fixed installation with front terminals for conventional switchboard and panel mounting.
  • Thermomagnetic protection operates without requiring an electronic trip-unit power supply.
  • Compact XT2 construction helps optimise space within low-voltage distribution equipment.
  • Part of ABB's established SACE Tmax XT circuit breaker platform.

Key Features

  • ABB SACE Tmax XT2V 160 moulded-case circuit breaker.
  • TMD thermomagnetic trip unit.
  • 5 A rated current (In).
  • 50 A magnetic short-circuit trip setting.
  • 160 A XT2 frame size (Iu).
  • 150 kA XT2V ultimate breaking-capacity class.
  • Three-pole construction.
  • Fixed (F) installation.
  • Front terminals (F).
  • Thermal protection against sustained overload conditions.
  • Magnetic protection against short-circuit faults.
  • Suitable for AC and DC low-voltage system-protection applications subject to the applicable ABB ratings.
  • Designed for system protection in accordance with the IEC/EN 60947-2 circuit breaker standard.

High-Capacity Thermomagnetic Circuit Protection

The ABB TMD trip unit combines two established protection principles within the circuit breaker. Its thermal element responds to sustained overload currents that could otherwise cause excessive heating of cables and connected equipment, while the magnetic element provides rapid operation when a high-current short-circuit fault occurs.

For the 1SDA067677R1, the TMD release has a rated current of 5 A with a magnetic short-circuit setting of 50 A. Combined with the very-high-breaking-capacity XT2V platform, this provides dependable protection for low-current circuits installed within electrical systems where substantial prospective short-circuit currents may be present.

Typical Applications

  • Low-voltage electrical distribution panels.
  • Industrial switchboards and control panels.
  • Commercial electrical distribution systems.
  • Three-phase low-current circuits.
  • Cable and feeder protection.
  • Machinery and equipment power circuits.
  • Generator and power distribution protection where correctly coordinated.
  • Installations with high prospective short-circuit currents.
  • Fixed ABB SACE Tmax XT circuit breaker assemblies.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Order code 1SDA067677R1
Product type Moulded-case circuit breaker (MCCB)
Frame XT2
Breaking-capacity version V
Frame rated current (Iu) 160 A
Trip unit TMD thermomagnetic
Rated current (In) 5 A
Magnetic short-circuit trip setting 50 A
XT2V ultimate short-circuit breaking capacity class 150 kA
Number of poles 3
Installation Fixed (F)
Terminal arrangement Front terminals (F)
Protection functions Thermal overload and magnetic short-circuit protection
Reference standard IEC/EN 60947-2
Product net weight 1.1 kg
GTIN / EAN 8015644015732
Customs tariff number 85362090

Frequently Asked Questions

What is the ABB 1SDA067677R1?

The ABB 1SDA067677R1 is an XT2V 160 three-pole moulded-case circuit breaker with a TMD thermomagnetic trip unit rated at 5 A and a 50 A magnetic short-circuit trip setting.

What does TMD 5-50 mean on the ABB XT2V?

TMD identifies the thermomagnetic trip unit. The circuit breaker has a rated current of 5 A and a magnetic short-circuit trip setting of 50 A.

What is the breaking capacity of the ABB XT2V 1SDA067677R1?

The ABB XT2V belongs to the 150 kA ultimate short-circuit breaking-capacity class, providing very high fault interruption capability for demanding low-voltage installations.

What do 3p F F mean in the ABB product description?

3p means the circuit breaker has three poles. The first F identifies a fixed installation and the second F identifies front terminals.

What protection does the ABB 1SDA067677R1 provide?

The TMD trip unit provides thermal overload protection and magnetic short-circuit protection, while the XT2V breaking part provides the high interruption capability required to safely disconnect severe fault currents.

Trusted Circuit Protection from ABB

ABB SACE Tmax XT moulded-case circuit breakers combine compact construction, dependable thermomagnetic protection and high short-circuit interruption capability for demanding industrial and commercial low-voltage electrical installations.