1SDA067637R1 ABB XT2L 160 TMD 12.5-125 3P F F Moulded-Case Circuit Breaker

1SDA067637R1 ABB XT2L 160 TMD 12.5-125 3P F F Moulded-Case Circuit Breaker

ABB 1SDA067637R1 is a 12.5 A three-pole XT2L 160 moulded-case circuit breaker with an adjustable TMD thermomagnetic release, 125 A instantaneous short-circuit protection, fixed mounting and front terminals.

SKU: 1SDA067637R1MPN: 1SDA067637R1
Price
List Price £487.07 ex VAT
Your Price (ex VAT) Save 25%
£365.30 25% OFF
You save £121.77 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £365.30
Trade pricing is personalised to your account

Manufacturer Lead Time

£365.30

Why Choose the ABB XT2L 160 TMD 12.5-125 3P F F Circuit Breaker?

The ABB 1SDA067637R1 is a compact, high-performance moulded-case circuit breaker (MCCB) designed for reliable protection of low-voltage power distribution systems. As part of the ABB SACE Tmax XT series, the XT2L 160 combines a compact 160 A frame with a TMD thermomagnetic release to provide dependable overload and short-circuit protection.

This circuit breaker features a fixed three-pole configuration with front terminals and a TMD thermomagnetic release. Its adjustable thermal protection provides protection against sustained overload conditions, while the fixed magnetic release provides rapid operation during short-circuit faults, making the breaker suitable for industrial and commercial electrical distribution applications.

With a rated current of 12.5 A, an adjustable overload release setting of 8.75–12.5 A and an instantaneous short-circuit setting of 125 A, the XT2L 160 TMD 12.5-125 provides precise circuit protection. It supports operational voltages up to 690 V AC and offers a rated ultimate short-circuit breaking capacity of 120 kA at 415 V AC.

Key Advantages

  • Compact ABB Tmax XT2L moulded-case circuit breaker for power distribution.
  • 12.5 A rated current with adjustable thermal overload protection.
  • 125 A instantaneous magnetic release for rapid short-circuit protection.
  • High 120 kA breaking capacity at 415 V AC.
  • Three-pole fixed configuration with front terminals for straightforward panel integration.
  • Suitable for both AC and DC power distribution applications.

Key Features

  • ABB SACE Tmax XT2L 160 circuit breaker.
  • 12.5 A rated current.
  • 8.75–12.5 A adjustable overload release range.
  • 125 A instantaneous short-circuit setting.
  • TMD thermomagnetic trip unit.
  • Three-pole configuration.
  • Fixed mounting with front terminal connections.
  • IP20 front-side protection rating.

Reliable Protection for Low-Voltage Power Distribution

Thermomagnetic circuit breakers combine thermal and magnetic protection mechanisms to protect electrical installations against damaging overcurrent conditions. The adjustable thermal element responds to sustained overloads, while the instantaneous magnetic release operates rapidly when a high short-circuit current occurs.

The ABB Tmax XT range is designed for compact and dependable low-voltage circuit protection. The XT2L platform combines high short-circuit performance with flexible installation and connection options, making the 1SDA067637R1 suitable for protecting distribution circuits, cables and electrical equipment in demanding industrial and commercial installations.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Commercial electrical distribution systems.
  • Electrical switchboards and control panels.
  • Cable and feeder circuit protection.
  • Industrial machinery power distribution.
  • OEM electrical equipment and panel building.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Order code 1SDA067637R1
Product type Moulded-case circuit breaker (MCCB)
Frame size XT2
Frame rating (Iu) 160 A
Rated current (In) 12.5 A
Trip unit TMD thermomagnetic release
Overload release setting 8.75–12.5 A
Instantaneous short-circuit setting (Ii) 125 A
Number of poles 3
Current type AC / DC
Rated operational voltage 690 V AC / 500 V DC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated frequency 50 / 60 Hz
Breaking capacity class L
Rated ultimate breaking capacity (Icu) at 415 V AC 120 kA
Rated service breaking capacity (Ics) at 415 V AC 120 kA
Mounting type Fixed
Terminal type Front terminals
Operating element Toggle
Protection rating IP20 front side
Power loss 1.05 W per pole
Electrical durability 8,000 operations
Mechanical durability 25,000 operations
Dimensions (W × H × D) 90 × 130 × 82.5 mm
Weight approx. 1.2 kg
EAN 8015644695460
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA067637R1 used for?

The ABB 1SDA067637R1 is a moulded-case circuit breaker designed to provide overload and short-circuit protection for low-voltage AC and DC power distribution circuits.

What is the rated current of the ABB XT2L 160 TMD 12.5-125?

The circuit breaker has a rated current of 12.5 A, with an adjustable thermal overload setting range of 8.75–12.5 A.

What does TMD mean on this ABB circuit breaker?

TMD identifies the thermomagnetic release, combining adjustable thermal overload protection with instantaneous magnetic short-circuit protection.

What is the short-circuit setting of the ABB 1SDA067637R1?

The circuit breaker has a rated instantaneous short-circuit current setting of 125 A.

What is the breaking capacity of the ABB 1SDA067637R1?

The XT2L 160 has a rated ultimate short-circuit breaking capacity of 120 kA at 415 V AC for this configuration.

Trusted ABB Circuit Protection

ABB SACE Tmax XT moulded-case circuit breakers provide compact and dependable protection for industrial and commercial power distribution systems, combining thermomagnetic circuit protection with high short-circuit performance and flexible installation options.