ABB XT2H 160 4 pole High MCCB Adjustable Thermal-Magnetic Release In=160A Ii=1600A

ABB XT2H 160 4 pole High MCCB Adjustable Thermal-Magnetic Release In=160A Ii=1600A

ABB 1SDA067627R1 XT2H 160 TMA 160-1600 4p F F InN=100% moulded case circuit breaker, a four-pole SACE Tmax XT MCCB with thermomagnetic release, fully rated neutral and front terminals for low-voltage circuit protection.

SKU: 1SDA067627R1Alt SKU: XT2H 160 TMA 160-1600 4p F F InN=100%MPN: 1SDA067627R1
Price
List Price £886.35 ex VAT
Your Price (ex VAT) Save 25%
£664.76 25% OFF
You save £221.59 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £664.76
Trade pricing is personalised to your account

Manufacturer Lead Time

£664.76

Why Choose the ABB 1SDA067627R1 XT2H 160 TMA 160-1600 4p F F InN=100% MCCB?

The ABB 1SDA067627R1 is a high-performance SACE Tmax XT moulded case circuit breaker (MCCB) designed for reliable low-voltage protection in industrial, commercial and panel-building applications. As part of the ABB Tmax XT2 series, it provides dependable overload and short-circuit protection for demanding electrical distribution systems.

This ABB XT2H 160 TMA 160-1600 4p F F InN=100% features a fixed four-pole construction with front terminals, making it suitable for switchboards, control panels and machinery supply circuits. Its thermomagnetic TMA release provides adjustable protection, while the fully rated neutral supports installations where neutral conductor protection is required.

With a rated current of 160 A, an instantaneous short-circuit setting range of 800–1600 A and a robust four-pole design, the ABB 1SDA067627R1 is ideal for installations requiring reliable isolation, high breaking capacity and long-term operational safety.

Key Advantages

  • ABB SACE Tmax XT2 moulded case circuit breaker for low-voltage distribution.
  • 160 A rated current suitable for demanding industrial and commercial circuits.
  • Four-pole configuration with fully rated neutral protection.
  • Thermomagnetic TMA release for overload and short-circuit protection.
  • 800–1600 A instantaneous short-circuit setting range for fault protection.
  • Fixed front-terminal design for straightforward panel installation.

Key Features

  • ABB SACE Tmax XT series.
  • XT2H 160 frame size.
  • 160 A rated current.
  • Four-pole MCCB construction.
  • Fully rated neutral, InN=100%.
  • TMA thermomagnetic release.
  • I3 short-circuit setting range of 800–1600 A.
  • Front terminals for fixed installation.

Reliable Circuit Protection for Low-Voltage Distribution

Moulded case circuit breakers such as the ABB XT2H 160 protect electrical installations from overloads and short circuits by disconnecting the circuit during fault conditions. This helps protect cables, switchgear and connected equipment while improving operational safety and reducing downtime.

The ABB 1SDA067627R1 is well suited to panel builders, electrical contractors and maintenance engineers requiring a dependable four-pole MCCB with fully rated neutral protection for switchboards, machinery circuits and industrial distribution panels.

Typical Applications

  • Low-voltage electrical distribution panels.
  • Industrial switchboards and control cabinets.
  • Machinery supply and protection circuits.
  • Commercial building power distribution.
  • Three-phase systems requiring neutral protection.
  • Electrical isolation and circuit protection systems.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Current 160 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 70 kA
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax XT
Model XT2H 160 TMA 160-1600 4p F F InN=100%
Product ID 1SDA067627R1
EAN 8015644015237
Product type Moulded case circuit breaker
Frame size XT2
Rated current 160 A
Number of poles 4 pole
Neutral rating Fully rated neutral, 100%
Release type Thermomagnetic TMA
Instantaneous short-circuit setting 800–1600 A
Rated operational voltage up to 690 V AC
Rated frequency 50 / 60 Hz
Breaking capacity 70 kA at 415 V AC
Mounting type Fixed
Terminal type Front terminals
Standard IEC 60947-2
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA067627R1 used for?

The ABB 1SDA067627R1 is used for overload and short-circuit protection in low-voltage industrial and commercial electrical distribution systems.

What type of circuit breaker is the 1SDA067627R1?

It is an ABB SACE Tmax XT moulded case circuit breaker with a thermomagnetic TMA release.

How many poles does this MCCB have?

The ABB 1SDA067627R1 is a four-pole moulded case circuit breaker.

What is the rated current of this breaker?

This breaker has a rated current of 160 A.

What does InN=100% mean on this ABB MCCB?

InN=100% means the neutral pole is fully rated, making the breaker suitable for applications where the neutral conductor requires the same current rating as the phase poles.