ABB XT2H 160 3 pole High MCCB Adjustable Thermal-Magnetic Release In=40A Ii=400A

ABB XT2H 160 3 pole High MCCB Adjustable Thermal-Magnetic Release In=40A Ii=400A

ABB 1SDA067598R1 XT2H 160 TMA 40-400 3p F F moulded case circuit breaker, a 40 A three-pole fixed MCCB with front terminals, TMA thermomagnetic release and 70 kA breaking capacity for low voltage circuit protection.

SKU: 1SDA067598R1Alt SKU: XT2H 160 TMA 40-400 3p F FMPN: 1SDA067598R1
Price
List Price £481.44 ex VAT
Your Price (ex VAT) Save 25%
£361.08 25% OFF
You save £120.36 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £361.08
Trade pricing is personalised to your account

Manufacturer Lead Time

£361.08

Why Choose the ABB 1SDA067598R1 XT2H 160 TMA 40-400 3p F F MCCB?

The ABB 1SDA067598R1 is a high-performance SACE Tmax XT moulded case circuit breaker designed for reliable protection of low voltage electrical distribution systems. Part of the ABB Tmax XT2H series, this MCCB is suitable for industrial, commercial and panel building applications where compact three-pole circuit protection with high breaking capacity is required.

This breaker is supplied in a fixed three-pole configuration with front terminals, making it suitable for installation in distribution boards, switchgear panels and electrical control cabinets. Its integrated TMA thermomagnetic release provides adjustable overload and short-circuit protection, helping safeguard cables, equipment and downstream circuits.

With a rated current of 40 A, an adjustable instantaneous magnetic trip setting range of 200-400 A and a high breaking capacity of 70 kA at 415 V AC, the ABB 1SDA067598R1 is ideal for demanding three-phase installations. The XT2H 160 frame combines compact dimensions with robust fault interruption performance for reliable low voltage protection.

Key Advantages

  • High-performance ABB Tmax XT moulded case circuit breaker.
  • 40 A rated current for low voltage distribution circuits.
  • Three-pole fixed MCCB for three-phase circuit protection.
  • TMA thermomagnetic release for adjustable overload and short-circuit protection.
  • Front terminal connection for practical panel wiring.
  • 70 kA breaking capacity at 415 V AC for demanding installations.

Key Features

  • ABB SACE Tmax XT2H 160 series.
  • 40 A rated current.
  • Three-pole configuration.
  • Fixed mounting design.
  • Front terminals for cable or busbar connection.
  • TMA thermomagnetic trip unit.
  • 200-400 A adjustable magnetic protection range.
  • Designed for dependable AC and DC low voltage circuit protection.

Reliable Three-Pole Circuit Protection

Moulded case circuit breakers such as the ABB 1SDA067598R1 are used to protect electrical installations from overloads and short circuits. By safely interrupting fault currents, they help reduce equipment damage, improve operational safety and support reliable power distribution.

The XT2H 160 frame is designed for installations requiring compact dimensions and higher short-circuit performance. This makes the ABB 1SDA067598R1 suitable for industrial switchboards, distribution boards, machinery panels and commercial electrical systems requiring dependable three-phase protection.

Typical Applications

  • Low voltage power distribution boards.
  • Industrial switchboards and control cabinets.
  • Three-phase circuit protection.
  • Commercial electrical distribution systems.
  • Motor control centres and automation panels.
  • OEM machinery and panel building projects.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Current 40 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Breaking Capacity 70 kA
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax XT
Frame XT2H 160
Model XT2H 160 TMA 40-400 3p F F
Product ID 1SDA067598R1
EAN 8015644014940
Product type Moulded case circuit breaker
Rated current 40 A
Number of poles 3 pole
Mounting type Fixed
Terminal type Front terminals
Trip unit TMA thermomagnetic release
Magnetic trip setting 200-400 A
Rated voltage 690 V AC
Rated operational voltage 690 V AC / 500 V DC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Rated frequency 50 / 60 Hz
Breaking capacity 70 kA at 415 V AC
Dimensions (H × W × D) approx. 130 × 90 × 82.5 mm
Weight approx. 1.4 kg
Standards IEC 60947-2
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA067598R1 used for?

The ABB 1SDA067598R1 is used to protect low voltage electrical circuits from overloads and short circuits in industrial, commercial and panel building applications.

What current rating does this MCCB have?

This moulded case circuit breaker has a rated current of 40 A.

How many poles does the ABB 1SDA067598R1 have?

The ABB 1SDA067598R1 is a three-pole MCCB, making it suitable for three-phase electrical systems.

What type of trip unit is fitted?

This breaker is fitted with a TMA thermomagnetic release, providing adjustable overload and short-circuit protection.

What is the breaking capacity of this MCCB?

The ABB 1SDA067598R1 has a breaking capacity of 70 kA at 415 V AC.

Trusted by Panel Builders Worldwide

ABB Tmax XT moulded case circuit breakers are trusted by electrical engineers, contractors and panel builders for reliable low voltage circuit protection in demanding industrial and commercial environments.