ABB XT2H 160 3 pole High MCCB Fixed Thermal/Adjustable Magnetic Release In=5A Ii=50A

ABB XT2H 160 3 pole High MCCB Fixed Thermal/Adjustable Magnetic Release In=5A Ii=50A

ABB XT2H 160 TMD 5-50 3P F F moulded case circuit breaker with thermal magnetic trip unit, 5 A rated current, three poles and high breaking capacity for industrial power distribution.

SKU: 1SDA067589R1Alt SKU: XT2H 160 TMD 5-50 3p F FMPN: 1SDA067589R1
Price
List Price £481.44 ex VAT
Your Price (ex VAT) Save 25%
£361.08 25% OFF
You save £120.36 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £361.08
Trade pricing is personalised to your account

Manufacturer Lead Time

£361.08

Why Choose the ABB 1SDA067589R1 XT2H 160 TMD 5-50 3P F F MCCB?

The ABB 1SDA067589R1 is a high-performance SACE Tmax XT2H moulded case circuit breaker (MCCB) designed to provide dependable protection against overloads and short circuits in industrial and commercial electrical distribution systems. As part of the proven ABB SACE Tmax XT series, this circuit breaker delivers excellent breaking performance, long operational life and reliable protection for critical installations.

Featuring a 160 A frame size with a thermal magnetic TMD trip unit adjustable from 3.5 to 5 A, the XT2H is suitable for protecting low current feeders, control circuits and specialised industrial applications. The fixed three-pole configuration with front terminals allows straightforward installation within switchboards and distribution panels.

Designed in accordance with IEC 60947-2, the ABB XT2H offers outstanding interrupting capacity, robust mechanical construction and compact dimensions, making it an excellent solution for machine builders, panel manufacturers and industrial facilities requiring dependable circuit protection.

Key Advantages

  • High-performance moulded case circuit breaker for industrial power distribution.
  • 160 A frame size with adjustable thermal magnetic protection.
  • High (H) breaking capacity for demanding applications.
  • Three-pole fixed configuration with front terminals.
  • Reliable overload and short-circuit protection.
  • Compact design simplifies panel installation.

Key Features

  • ABB SACE Tmax XT2H series.
  • Product code: 1SDA067589R1.
  • Thermal magnetic TMD trip unit.
  • Rated current: 5 A.
  • Adjustable thermal setting: 3.5 to 5 A.
  • Rated operational voltage: up to 690 V AC.
  • Three-pole fixed breaker.
  • Front terminal connections.
  • Designed to IEC 60947-2.
  • Suitable for industrial switchboards and control panels.

Reliable Protection for Electrical Distribution Systems

The ABB XT2H moulded case circuit breaker is engineered to safeguard electrical systems by automatically disconnecting circuits during overload or fault conditions. Its thermal magnetic trip unit provides dependable protection while maintaining operational continuity for industrial equipment and power distribution systems.

The SACE Tmax XT range combines high interrupting performance, compact dimensions and dependable mechanical durability, making it suitable for switchboards, OEM machinery, industrial control panels and commercial electrical installations.

Typical Applications

  • Industrial switchboards.
  • Electrical distribution panels.
  • OEM machinery.
  • Motor control centres.
  • Commercial electrical installations.
  • Industrial automation systems.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Current 5 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Breaking Capacity 70 kA
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax XT
Model XT2H 160 TMD 5-50 3P F F
Product code 1SDA067589R1
Product type Moulded case circuit breaker (MCCB)
Frame size XT2 160
Number of poles 3
Trip unit Thermal magnetic (TMD)
Rated current (In) 5 A
Thermal adjustment range 3.5 to 5 A
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Breaking capacity Up to 70 kA at 415 V AC
Frequency 50 / 60 Hz
Terminal type Front terminals
Mounting Fixed
Dimensions (H × W × D) Approx. 130 × 90 × 82.5 mm
Weight Approx. 1.1 kg
Standards IEC 60947-2
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA067589R1 used for?

This moulded case circuit breaker protects electrical circuits against overloads and short circuits in industrial and commercial power distribution systems.

How many poles does this MCCB have?

The ABB 1SDA067589R1 is supplied as a three-pole fixed circuit breaker.

What trip unit is fitted?

The breaker incorporates an adjustable thermal magnetic TMD trip unit with a thermal setting range of 3.5 to 5 A.

What is the rated operational voltage?

The XT2H is designed for operation on systems up to 690 V AC.