ABB XT2S 160 3 pole Standard MCCB Adjustable Thermal-Magnetic Release In=125A Ii=1250A

ABB XT2S 160 3 pole Standard MCCB Adjustable Thermal-Magnetic Release In=125A Ii=1250A

ABB 1SDA067559R1 XT2S 160 TMA 125-1250 3p F F moulded case circuit breaker, a 125 A three-pole fixed MCCB with front terminals and TMA thermomagnetic release for low voltage circuit protection.

SKU: 1SDA067559R1Alt SKU: XT2S 160 TMA 125-1250 3p F FMPN: 1SDA067559R1
Price
List Price £461.31 ex VAT
Your Price (ex VAT) Save 25%
£345.98 25% OFF
You save £115.33 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £345.98
Trade pricing is personalised to your account

Manufacturer Lead Time

£345.98

Why Choose the ABB 1SDA067559R1 XT2S 160 TMA 125-1250 3p F F MCCB?

The ABB 1SDA067559R1 is a high-performance SACE Tmax XT moulded case circuit breaker designed for dependable protection of low voltage electrical distribution systems. Part of the advanced ABB Tmax XT2 series, this MCCB provides reliable overload and short-circuit protection for commercial, industrial and panel building applications.

This circuit breaker is supplied in a fixed three-pole configuration with front terminals, making it suitable for installation in distribution boards, switchgear panels and machine control assemblies. Its integrated TMA thermomagnetic release provides effective protection with adjustable magnetic trip settings for improved application flexibility.

With a rated current of 125 A and an Icu breaking capacity of 50 kA at 415 V AC, the ABB 1SDA067559R1 is ideal for demanding installations where safe, compact and reliable circuit protection is required. The XT2S frame supports robust performance while maintaining a compact footprint for efficient panel design.

Key Advantages

  • High-quality ABB Tmax XT moulded case circuit breaker.
  • 125 A rated current for low voltage power distribution.
  • Three-pole fixed MCCB for three-phase circuit protection.
  • TMA thermomagnetic release for overload and short-circuit protection.
  • Front terminal connection for straightforward panel wiring.
  • Compact XT2 frame design suitable for switchboards and control panels.

Key Features

  • ABB SACE Tmax XT2S 160 series.
  • 125 A rated current.
  • Three-pole configuration.
  • Fixed mounting design.
  • Front terminals for cable or busbar connection.
  • TMA thermomagnetic trip unit.
  • Adjustable instantaneous magnetic protection range.
  • Designed for reliable protection in low voltage distribution systems.

Reliable Circuit Protection for Electrical Distribution

Moulded case circuit breakers such as the ABB 1SDA067559R1 are used to protect electrical systems from overloads and short circuits. By interrupting fault currents safely, they help prevent equipment damage, reduce downtime and support safer operation of low voltage installations.

The ABB Tmax XT range is widely used by panel builders, contractors and electrical engineers because it combines compact dimensions, dependable protection and flexible installation options. The XT2S 160 frame is particularly well suited to industrial panels, distribution boards and OEM electrical systems requiring robust three-phase protection.

Typical Applications

  • Low voltage power distribution panels.
  • Industrial switchboards and control cabinets.
  • Three-phase machinery protection.
  • Commercial electrical distribution systems.
  • Motor control centres and automation panels.
  • OEM equipment and panel building projects.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Current 125 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Breaking Capacity 50 kA
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax XT
Frame XT2S 160
Model XT2S 160 TMA 125-1250 3p F F
Product ID 1SDA067559R1
Product type Moulded case circuit breaker
Rated current 125 A
Number of poles 3 pole
Mounting type Fixed
Terminal type Front terminals
Trip unit TMA thermomagnetic release
Magnetic trip setting 625-1250 A
Rated AC voltage up to 690 V AC
Rated DC voltage up to 500 V DC
Breaking capacity 50 kA at 415 V AC
Standards IEC
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA067559R1 used for?

The ABB 1SDA067559R1 is used to protect low voltage electrical circuits from overloads and short circuits in industrial and commercial distribution systems.

What current rating does this MCCB have?

This moulded case circuit breaker has a rated current of 125 A.

How many poles does the ABB 1SDA067559R1 have?

The ABB 1SDA067559R1 is a three-pole MCCB, making it suitable for three-phase electrical systems.

What type of trip unit is fitted?

This breaker is fitted with a TMA thermomagnetic release, providing overload and short-circuit protection.

Where is this circuit breaker typically installed?

It is typically installed in distribution boards, switchgear panels, industrial control cabinets and low voltage electrical assemblies.

Trusted by Panel Builders Worldwide

ABB Tmax XT moulded case circuit breakers are trusted by electrical engineers, contractors and panel builders for dependable low voltage circuit protection in demanding industrial and commercial environments.