ABB XT2N 160 4 pole Normal MCCB Adjustable Thermal-Magnetic Release In=125A Ii=1250A

ABB XT2N 160 4 pole Normal MCCB Adjustable Thermal-Magnetic Release In=125A Ii=1250A

ABB XT2N 160 TMA 125-1250 four-pole moulded case circuit breaker with thermal magnetic trip unit, 125 A rated current and 36 kA breaking capacity for industrial power distribution.

SKU: 1SDA067040R1Alt SKU: XT2N 160 TMA 125-1250 4p F F InN=50%MPN: 1SDA067040R1
Price
List Price £637.15 ex VAT
Your Price (ex VAT) Save 25%
£477.86 25% OFF
You save £159.29 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £477.86
Trade pricing is personalised to your account

Manufacturer Lead Time

£477.86

Why Choose the ABB 1SDA067040R1 XT2N 160 Moulded Case Circuit Breaker?

The ABB 1SDA067040R1 is a premium moulded case circuit breaker (MCCB) from the ABB SACE Tmax XT series, engineered to provide dependable protection for industrial and commercial low voltage power distribution systems. This model is configured as XT2N 160 TMA 125-1250 4p F F InN=50%, offering robust overload and short-circuit protection together with a reduced neutral rating for balanced distribution applications.

Equipped with a thermal magnetic TMA trip unit, the breaker provides reliable protection against overloads and fault currents while maintaining a compact footprint. The fixed four-pole design with front terminals allows straightforward installation in switchboards, motor control centres and electrical distribution panels.

With a 125 A rated current, a 160 A frame size and a 36 kA breaking capacity at 415 V AC, the ABB 1SDA067040R1 delivers dependable circuit protection for demanding industrial environments while complying with IEC 60947-2 requirements.

Key Advantages

  • Compact ABB SACE Tmax XT moulded case circuit breaker.
  • 125 A rated current within the XT2N 160 frame.
  • Thermal magnetic TMA release for dependable overload and short-circuit protection.
  • 36 kA breaking capacity at 415 V AC.
  • Four-pole fixed construction with front terminals.
  • Neutral rated at 50% of phase current for suitable distribution applications.

Key Features

  • ABB SACE Tmax XT series.
  • XT2N 160 TMA 125-1250 4p F F InN=50%.
  • 125 A rated current.
  • 160 A frame size.
  • Thermal magnetic trip unit.
  • Fixed four-pole configuration.
  • Front terminal connections.
  • Suitable for AC and DC distribution systems.

Reliable Protection for Low Voltage Distribution

The ABB 1SDA067040R1 protects electrical installations against overloads and short-circuit faults, helping to safeguard cables, switchgear, transformers and connected equipment. Its thermal magnetic release offers fast and dependable operation while reducing downtime and maintenance requirements.

As part of the ABB SACE Tmax XT range, this MCCB provides proven reliability, compact dimensions and excellent electrical performance for industrial control panels, switchboards and commercial electrical installations.

Typical Applications

  • Industrial power distribution systems.
  • Electrical switchboards.
  • Commercial distribution panels.
  • Motor control centres.
  • Machine control panels.
  • Infrastructure and building services.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Current 125 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 36 kA
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax XT
Model XT2N 160 TMA 125-1250 4p F F InN=50%
Product ID 1SDA067040R1
Product type Moulded case circuit breaker
Number of poles 4P
Rated current 125 A
Rated uninterrupted current 160 A
Trip unit Thermal magnetic TMA
Trip setting range 87.5...125 A
Instantaneous trip setting 625...1250 A
Neutral rating 50% of phase current
Rated operational voltage Up to 690 V AC / 500 V DC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Breaking capacity 36 kA at 415 V AC
Frequency 50 / 60 Hz
Terminal type Front terminals
Mounting Fixed
Protection standard IEC 60947-2
Dimensions (H × W × D) approx. 130 × 120 × 82.5 mm
Weight approx. 1.45 kg
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA067040R1 used for?

It provides overload and short-circuit protection for low voltage industrial and commercial electrical distribution systems.

What is the rated current of this MCCB?

The ABB 1SDA067040R1 has a rated current of 125 A within the XT2N 160 frame.

What type of trip unit does it use?

This breaker is fitted with a thermal magnetic TMA trip unit with an instantaneous trip setting of 625 to 1250 A.

What breaking capacity does it provide?

The breaker provides a rated short-circuit breaking capacity of 36 kA at 415 V AC.