ABB XT2N 160 3 pole Normal MCCB Adjustable Thermal-Magnetic Release In=125A Ii=1250A

ABB XT2N 160 3 pole Normal MCCB Adjustable Thermal-Magnetic Release In=125A Ii=1250A

ABB 1SDA067019R1 Tmax XT2N 160 moulded case circuit breaker, 125 A three pole fixed MCCB with front terminals and TMA thermal-magnetic release for low voltage circuit protection.

SKU: 1SDA067019R1Alt SKU: XT2N 160 TMA 125-1250 3p F FMPN: 1SDA067019R1
Price
List Price £414.59 ex VAT
Your Price (ex VAT) Save 25%
£310.94 25% OFF
You save £103.65 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £310.94
Trade pricing is personalised to your account

Manufacturer Lead Time

£310.94

Why Choose the ABB 1SDA067019R1 Tmax XT2N 160 MCCB?

The ABB 1SDA067019R1 is a reliable moulded case circuit breaker (MCCB) from the ABB Tmax XT range, designed to provide dependable protection for low voltage electrical distribution systems. Identified as XT2N 160 TMA 125-1250 3p F F, this fixed three-pole circuit breaker is suitable for industrial and commercial applications requiring robust overload and short-circuit protection.

This ABB Tmax XT2N MCCB is fitted with a thermal-magnetic TMA release, providing protection against sustained overloads and high fault currents. Its adjustable magnetic protection range allows engineers to configure short-circuit protection according to the requirements of the installation.

With a rated current of 125 A, a 160 A frame size and front terminal connections, the 1SDA067019R1 is ideal for switchboards, distribution panels, machinery protection and panel building applications. Its compact fixed design supports efficient integration into modern low voltage electrical assemblies.

Key Advantages

  • Reliable ABB Tmax XT moulded case circuit breaker for low voltage protection.
  • 125 A rated current for industrial and commercial distribution circuits.
  • Three-pole fixed configuration suitable for three-phase electrical systems.
  • Thermal-magnetic TMA release for overload and short-circuit protection.
  • Front terminal connection for straightforward panel wiring.
  • Compact XT2 frame design for efficient switchboard installation.

Key Features

  • ABB Tmax XT2N 160 MCCB.
  • 125 A rated current.
  • Three-pole circuit breaker for three-phase systems.
  • Fixed mounting configuration.
  • Front terminals for standard cable connection.
  • TMA thermal-magnetic trip unit.
  • Adjustable magnetic protection range of 625-1250 A.
  • Designed for power distribution, switchboards and machinery protection.

Reliable Circuit Protection for Low Voltage Systems

Moulded case circuit breakers such as the ABB 1SDA067019R1 are used to protect cables, electrical circuits and connected equipment from damage caused by overloads and short circuits. When a fault condition occurs, the breaker disconnects the circuit to help protect equipment, reduce downtime and support safe electrical operation.

The ABB Tmax XT range is widely used in industrial power distribution panels, commercial switchboards, machinery control systems and motor control centres. Its compact construction, adjustable protection and proven ABB design make it a dependable choice for professional low voltage installations.

Typical Applications

  • Industrial power distribution boards.
  • Commercial electrical switchboards.
  • Motor control centres and machinery panels.
  • Building services and infrastructure systems.
  • Three-phase power protection circuits.
  • Panel builder and OEM electrical assemblies.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Current 125 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Breaking Capacity 36 kA
Trip Unit Thermal-magnetic
Manufacturer ABB
Series Tmax XT
Model XT2N 160 TMA 125-1250 3p F F
Product ID 1SDA067019R1
Product type Moulded case circuit breaker
Frame size XT2N 160
Rated current 125 A
Number of poles 3 pole
Release type Thermal-magnetic TMA
Magnetic setting range 625-1250 A
Mounting type Fixed
Terminal type Front terminals
Rated operational voltage up to 690 V AC
Breaking capacity 36 kA at 415 V AC
EAN 8015644009250
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA067019R1 used for?

The ABB 1SDA067019R1 is used to protect low voltage three-phase electrical circuits against overloads and short circuits.

What type of circuit breaker is the 1SDA067019R1?

It is an ABB Tmax XT2N moulded case circuit breaker with a fixed three-pole configuration and front terminals.

What is the rated current of this MCCB?

The 1SDA067019R1 has a rated current of 125 A.

What trip unit does this MCCB use?

This circuit breaker uses a TMA thermal-magnetic release for overload and short-circuit protection.

Where is this ABB MCCB typically installed?

It is typically installed in electrical panels, switchboards, power distribution systems and industrial control assemblies.

Trusted by Electrical Professionals Worldwide

ABB Tmax XT moulded case circuit breakers are trusted by panel builders, electrical contractors and industrial engineers for dependable circuit protection, compact installation and long-term performance in low voltage distribution systems.