ABB XT1B 160 4 pole Basic MCCB Fixed Thermal/Adjustable Magnetic Release In=125A Ii=1250A

ABB XT1B 160 4 pole Basic MCCB Fixed Thermal/Adjustable Magnetic Release In=125A Ii=1250A

ABB 1SDA066888R1 XT1B 160 TMD 125-1250 4P F F InN=100% moulded case circuit breaker with 125 A rated current, four poles, fully rated neutral, thermomagnetic TMD release and fixed front terminals for low voltage power distribution.

SKU: 1SDA066888R1Alt SKU: XT1B 160 TMD 125-1250 4p F F InN=100%MPN: 1SDA066888R1
Price
List Price £546.23 ex VAT
Your Price (ex VAT) Save 25%
£409.67 25% OFF
You save £136.56 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £409.67
Trade pricing is personalised to your account

Manufacturer Lead Time

£409.67

Why Choose the ABB XT1B 160 TMD 125-1250 4P F F InN=100% Moulded Case Circuit Breaker?

The ABB 1SDA066888R1 XT1B 160 TMD 125-1250 4P F F InN=100% is a compact and dependable moulded case circuit breaker (MCCB) from the ABB SACE Tmax XT series. Designed for low voltage power distribution, it provides reliable protection against overloads and short circuits in industrial, commercial and OEM electrical installations.

This four-pole MCCB is fitted with an adjustable thermomagnetic TMD trip unit, combining thermal overload protection with magnetic short circuit protection. The fully rated neutral design provides InN=100%, making it suitable for applications where the neutral pole must carry the full rated phase current.

With a 125 A rated current, XT1 160 A frame size and 18 kA breaking capacity at 415 V AC, the ABB XT1B 160 TMD 125-1250 4P F F InN=100% is well suited to feeder protection, distribution boards, machinery supplies and general low voltage electrical systems.

Key Advantages

  • Compact ABB SACE Tmax XT moulded case circuit breaker.
  • 125 A rated current for dependable low voltage protection.
  • Four-pole configuration with fully rated neutral.
  • InN=100% neutral pole rating for full neutral current capability.
  • Thermomagnetic TMD release for overload and short circuit protection.
  • 18 kA breaking capacity at 415 V AC.
  • Fixed MCCB with front terminal connections.
  • Designed in accordance with IEC 60947-2.

Key Features

  • ABB SACE Tmax XT series.
  • Model: XT1B 160 TMD 125-1250 4P F F InN=100%.
  • Product ID: 1SDA066888R1.
  • 125 A rated current.
  • 160 A frame size.
  • Four-pole MCCB construction.
  • Neutral rating: 100% of phase current.
  • Adjustable thermomagnetic TMD trip unit.
  • Front terminal connection type.
  • Fixed mounting version for panel installation.

Reliable Protection for Low Voltage Power Distribution

The ABB XT1B range is engineered to protect electrical circuits by disconnecting power during overload or short circuit conditions. The thermomagnetic release provides a dependable combination of time-delayed overload protection and rapid magnetic fault interruption, helping protect cables, equipment and downstream devices.

Its compact fixed format, four-pole arrangement and fully rated neutral make this MCCB suitable for panel builders, electrical contractors and machine manufacturers requiring reliable protection in demanding low voltage installations.

Typical Applications

  • Industrial power distribution systems.
  • Commercial switchboards and distribution panels.
  • OEM machinery and control cabinets.
  • Feeder circuit protection.
  • Manufacturing and process equipment.
  • Building services and infrastructure systems.
  • Low voltage AC and DC electrical protection.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Current 125 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 18 kA
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax XT
Model XT1B 160 TMD 125-1250 4P F F InN=100%
Product code 1SDA066888R1
EAN 8015644007911
Product type Moulded Case Circuit Breaker (MCCB)
Frame size XT1 160
Rated current (In) 125 A
Rated uninterrupted current (Iu) 160 A
Neutral rating 100% of phase current
Number of poles 4
Trip unit Thermomagnetic TMD
Thermal setting range 87.5 to 125 A
Instantaneous magnetic setting 1250 A
Rated operational voltage Up to 690 V AC / 500 V DC
Rated insulation voltage 800 V
Rated impulse withstand voltage 8 kV
Breaking capacity (Icu) 18 kA at 415 V AC
Terminal type Front terminals
Mounting type Fixed
Frequency 50 / 60 Hz
Standards IEC 60947-2
Protection rating IP20 device rating
Dimensions (H × W × D) approx. 130 × 101.6 × 70 mm
Weight approx. 1.4 kg
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA066888R1 used for?

It is used to protect low voltage electrical circuits against overloads and short circuits in industrial, commercial and OEM power distribution systems.

What is the rated current of this MCCB?

The ABB 1SDA066888R1 has a 125 A rated current and is built on the XT1 160 A frame size.

What does InN=100% mean on this breaker?

InN=100% means the neutral pole is fully rated and can carry 100% of the phase current.

What type of trip unit is included?

The breaker is fitted with an adjustable thermomagnetic TMD trip unit for overload and short circuit protection.

What terminals does the XT1B 160 TMD 125-1250 4P F F InN=100% use?

This fixed MCCB uses front terminals, making it suitable for standard installation in switchboards, control panels and distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are trusted by panel builders, electrical contractors and industrial engineers for dependable circuit protection, compact installation and long service life in demanding low voltage systems.