1SDA065797R1 ABB T8V 3200 PR331/P LSIG 3200 A 4-Pole Circuit Breaker

1SDA065797R1 ABB T8V 3200 PR331/P LSIG 3200 A 4-Pole Circuit Breaker

ABB 1SDA065797R1 T8V 3200 four-pole fixed moulded-case circuit breaker with a 3200 A rating, PR331/P LSIG electronic trip unit, rear vertical terminals and 130 kA ultimate breaking capacity at 415 V AC.

SKU: 1SDA065797R1MPN: 1SDA065797R1
Price
List Price £41,456.88 ex VAT
Your Price (ex VAT) Save 25%
£31,092.66 25% OFF
You save £10,364.22 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £31,092.66
Trade pricing is personalised to your account

Manufacturer Lead Time

£31,092.66

Why Choose the ABB T8V 3200 PR331/P LSIG 1SDA065797R1 Circuit Breaker?

The ABB T8V 3200 PR331/P LSIG 1SDA065797R1 is a high-capacity four-pole moulded-case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage power distribution systems. As part of the ABB SACE Tmax T8 series, it combines a 3200 A current rating with an electronic LSIG protection trip unit for comprehensive protection of industrial switchboards, feeders and distribution equipment.

This circuit breaker incorporates the PR331/P LSIG solid-state electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. The combination of these protection functions makes the breaker particularly suitable for coordinated distribution systems where selective fault protection and earth-fault detection are required.

With a rated uninterrupted current of 3200 A, a four-pole fixed configuration and rear vertical terminals, the T8V 3200 is designed for high-current installation within low-voltage switchboards and power distribution assemblies. The T8V performance level provides an ultimate short-circuit breaking capacity of 130 kA at 415 V AC, supporting installations with high prospective fault currents.

Key Advantages

  • High-capacity 3200 A moulded-case circuit breaker for industrial power distribution.
  • Four-pole configuration for comprehensive switching and circuit protection.
  • PR331/P LSIG electronic trip unit provides advanced adjustable protection.
  • LSIG functionality includes overload, selective short-circuit, instantaneous and earth-fault protection.
  • 130 kA ultimate short-circuit breaking capacity at 415 V AC for demanding electrical installations.
  • Fixed construction with rear vertical terminals for switchboard integration.

Key Features

  • ABB SACE Tmax T8V 3200 series.
  • 3200 A rated uninterrupted current.
  • Four-pole fixed circuit breaker.
  • PR331/P LSIG solid-state electronic release.
  • Long-time overload protection.
  • Short-time selective short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • 130 kA Icu at 415 V AC.
  • 690 V AC rated operational voltage.
  • Rear vertical main terminals for fixed switchboard installation.

Advanced LSIG Protection for Power Distribution

Moulded-case circuit breakers such as the ABB Tmax T8 protect electrical distribution systems against damaging overload and short-circuit currents while providing circuit switching and isolation. The high breaking performance of the T8V makes it particularly suitable for major distribution points where high prospective fault currents can occur.

The PR331/P LSIG electronic trip unit extends protection to include earth faults alongside long-time overload, short-time selective and instantaneous short-circuit protection. This comprehensive protection arrangement helps engineers coordinate upstream and downstream protective devices while safeguarding cables, busbars and connected electrical equipment.

Typical Applications

  • Main incoming circuit protection in industrial switchboards.
  • High-current low-voltage power distribution systems.
  • Transformer secondary distribution protection.
  • Industrial feeder and busbar protection.
  • Systems requiring integrated earth-fault protection.
  • Manufacturing and process-industry electrical installations.
  • Commercial and infrastructure power distribution assemblies.

Technical Specifications

Series SACE Tmax T8
ABB order code 1SDA065797R1
ABB product group 310511-T-Max T4 - T8
Product type Moulded-case circuit breaker
Rated uninterrupted current (Iu) 3200 A
Number of poles 4
Rated operational voltage 690 V AC
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 130 kA
Trip unit PR331/P LSIG electronic trip unit
Protection functions LSIG – long-time, short-time, instantaneous and earth fault
Complete device with protection unit Yes
Integrated earth-fault protection Yes
Installation Fixed
Main terminal position Rear
Terminal orientation Vertical (VR)
EAN 8015644687083

Frequently Asked Questions

What is the ABB 1SDA065797R1 used for?

The ABB 1SDA065797R1 is used for high-current protection and switching in low-voltage power distribution systems, including industrial switchboards, main feeders and distribution assemblies.

What current rating does the ABB T8V 3200 have?

The circuit breaker has a rated uninterrupted current of 3200 A.

What protection functions does the PR331/P LSIG trip unit provide?

The PR331/P LSIG electronic trip unit provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection.

What is the breaking capacity of the ABB 1SDA065797R1?

The T8V version has an ultimate short-circuit breaking capacity of 130 kA at 415 V AC.