1SDA065796R1 ABB T8V 3200 PR232/P LSI 3200 A 4-Pole Circuit Breaker

1SDA065796R1 ABB T8V 3200 PR232/P LSI 3200 A 4-Pole Circuit Breaker

ABB 1SDA065796R1 T8V 3200 four-pole fixed moulded-case circuit breaker with a 3200 A rating, PR232/P-T8 LSI electronic trip unit, rear vertical terminals and 130 kA breaking capacity at 415 V AC.

SKU: 1SDA065796R1MPN: 1SDA065796R1
Price
List Price £40,623.63 ex VAT
Your Price (ex VAT) Save 25%
£30,467.72 25% OFF
You save £10,155.91 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £30,467.72
Trade pricing is personalised to your account

Manufacturer Lead Time

£30,467.72

Why Choose the ABB T8V 3200 PR232/P LSI 1SDA065796R1 Circuit Breaker?

The ABB T8V 3200 PR232/P LSI 1SDA065796R1 is a high-capacity four-pole moulded-case circuit breaker (MCCB) designed for protection and switching of low-voltage power distribution systems. As part of the ABB SACE Tmax T8 series, it combines a robust 3200 A breaker frame with an electronic LSI protection trip unit for dependable protection of industrial installations, transformers, generators and distribution equipment.

This T8V circuit breaker incorporates the PR232/P-T8 LSI electronic trip unit, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection. The electronic protection system is designed to support selective and coordinated protection schemes while helping safeguard cables, busbars and connected electrical equipment against damaging overcurrents and fault conditions.

With a rated uninterrupted current of 3200 A, a four-pole fixed configuration and rear vertical terminals, the 1SDA065796R1 is intended for high-current fixed installations within switchboards and power distribution assemblies. The T8V performance level provides a rated ultimate short-circuit breaking capacity of 130 kA at 415 V AC, making it suitable for demanding installations with high prospective fault currents.

Key Advantages

  • High-capacity 3200 A moulded-case circuit breaker for industrial power distribution.
  • Four-pole configuration enables switching and protection across four conductors.
  • Integrated PR232/P-T8 LSI electronic trip unit for long-time, short-time and instantaneous protection.
  • 130 kA ultimate breaking capacity at 415 V AC for demanding fault-current conditions.
  • Fixed installation with rear vertical terminals for integration into switchboards and distribution assemblies.
  • ABB Tmax construction provides dependable circuit protection for critical low-voltage installations.

Key Features

  • ABB SACE Tmax T8V 3200 series.
  • 3200 A rated uninterrupted current.
  • Four poles.
  • PR232/P-T8 LSI electronic protection trip unit.
  • Long-time overload, short-time short-circuit and instantaneous short-circuit protection.
  • 130 kA Icu at 415 V AC.
  • 690 V AC rated operational voltage.
  • Fixed breaker construction with rear vertical main terminals.
  • IP20 protection rating.

Reliable Circuit Protection for High-Current Power Distribution

Moulded-case circuit breakers such as the ABB Tmax T8 protect electrical distribution systems against overloads and short circuits while also providing a means of isolating circuits for operation and maintenance. High breaking capacity is particularly important in industrial switchboards where prospective short-circuit currents can be substantial.

The PR232/P-T8 LSI electronic trip unit provides long-time protection against sustained overloads together with short-time and instantaneous protection against short-circuit conditions. This combination makes the T8V suitable for coordinated protection schemes in large industrial and commercial low-voltage distribution systems.

Typical Applications

  • Main incoming circuit protection in industrial switchboards.
  • High-current low-voltage power distribution systems.
  • Transformer secondary and distribution protection.
  • Generator and installation protection.
  • Busbar and feeder circuit protection.
  • Manufacturing plants and process-industry electrical systems.
  • Commercial and infrastructure power distribution assemblies.

Technical Specifications

Series SACE Tmax T8
ABB order code 1SDA065796R1
ABB product group 310511-T-Max T4 - T8
Product type Moulded-case circuit breaker
Rated uninterrupted current (Iu) 3200 A
Number of poles 4
Rated operational voltage 690 V AC
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 130 kA
Trip unit PR232/P-T8 LSI electronic trip unit
Protection functions LSI – long-time, short-time and instantaneous
Installation Fixed
Main terminal position Rear
Terminal orientation Vertical (VR)
Main circuit connection Bolted connection
Protection rating IP20

Frequently Asked Questions

What is the ABB 1SDA065796R1 used for?

This ABB Tmax T8V circuit breaker is used for high-current protection and switching in low-voltage power distribution systems, including switchboards, transformer circuits, generator installations and industrial feeders.

What current rating does the ABB T8V 3200 have?

The 1SDA065796R1 has a rated uninterrupted current of 3200 A.

What protection functions are provided by the PR232/P-T8 trip unit?

The PR232/P-T8 LSI electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the 1SDA065796R1?

The T8V version has an ultimate short-circuit breaking capacity of 130 kA at 415 V AC.

How is this circuit breaker installed?

The 1SDA065796R1 is a four-pole fixed circuit breaker designed for switchboard installation and is supplied with rear vertical main terminals.

Trusted for Industrial Power Distribution

ABB SACE Tmax circuit breakers are widely used in industrial and commercial power distribution systems to provide dependable overload and short-circuit protection, high breaking performance and flexible integration into low-voltage switchboards.