1SDA065762R1 ABB T8L 2500 PR332/P-LSIG 2500 A 3P MCCB

1SDA065762R1 ABB T8L 2500 PR332/P-LSIG 2500 A 3P MCCB

ABB 1SDA065762R1 is a 2500 A three-pole fixed SACE Tmax T8L moulded case circuit breaker with a PR332/P-LSIG electronic trip unit providing long-time, short-time, instantaneous and ground-fault protection for high-current industrial power distribution.

SKU: 1SDA065762R1MPN: 1SDA065762R1
Price
List Price £23,253.06 ex VAT
Your Price (ex VAT) Save 25%
£17,439.80 25% OFF
You save £5,813.27 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £17,439.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£17,439.80

Why Choose the ABB 1SDA065762R1 T8L 2500 Circuit Breaker?

The ABB 1SDA065762R1 is a high-current SACE Tmax T8L 2500 moulded case circuit breaker (MCCB) designed for demanding industrial power distribution systems. Identified by ABB as T8L 2500 PR332/P LSIG In=2500A 3p F F, it combines a 2500 A rated current, three-pole construction and an advanced PR332/P-LSIG electronic trip unit.

The PR332/P-LSIG trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection. These electronic protection functions make the breaker suitable for high-current distribution networks requiring comprehensive protection against overloads, short circuits and earth faults.

The T8L 2500 platform is designed for high-power low-voltage distribution and offers a rated operational voltage up to 690 V AC. The 1SDA065762R1 features fixed mounting with front terminals, providing a robust configuration for integration into industrial switchboards, main distribution panels and other high-current electrical installations.

Key Advantages

  • High-current ABB SACE Tmax T8L 2500 MCCB for demanding industrial distribution.
  • 2500 A rated current for large electrical loads and main distribution circuits.
  • PR332/P-LSIG electronic trip unit for comprehensive circuit protection.
  • Long-time, short-time, instantaneous and ground-fault protection.
  • Three-pole configuration for three-phase power distribution systems.
  • Fixed construction with front terminals for permanent switchboard installation.

Key Features

  • ABB SACE Tmax T8L 2500 circuit breaker.
  • 2500 A rated current (In).
  • Three-pole configuration.
  • PR332/P-LSIG electronic trip unit.
  • L: long-time overload protection.
  • S: short-time short-circuit protection.
  • I: instantaneous short-circuit protection.
  • G: ground-fault protection.
  • Suitable for systems with operational voltage up to 690 V AC.
  • Fixed installation with front main-circuit connections.

Advanced PR332/P-LSIG Protection for High-Current Distribution

High-current distribution systems require protection capable of responding appropriately to sustained overloads, short-duration fault currents, severe short circuits and ground faults. The ABB PR332/P-LSIG electronic trip unit provides these four protection functions within the Tmax T8 platform, allowing the circuit breaker to protect demanding industrial distribution circuits against a broad range of electrical fault conditions.

The ABB 1SDA065762R1 combines this electronic protection with a 2500 A three-pole T8L circuit breaker. Its fixed construction and front connections make it particularly suitable for permanent installation in main switchboards and power distribution assemblies where high current capacity and comprehensive electronic protection are required.

Typical Applications

  • Industrial main power distribution switchboards.
  • High-current three-phase distribution systems.
  • Manufacturing and process industry electrical infrastructure.
  • Distribution systems requiring electronic ground-fault protection.
  • Transformer secondary and main distribution circuits.
  • Commercial and industrial low-voltage switchgear assemblies.

Technical Specifications

Series SACE Tmax T8
Breaker version T8L 2500
ABB product group 310511-T-Max T4 - T8
Order code / SKU 1SDA065762R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 2500 A
Frame / breaker size T8 2500
Number of poles 3
Trip unit PR332/P-LSIG
Trip-unit technology Electronic
Protection functions Long-time, short-time, instantaneous and ground-fault (LSIG)
Rated operational voltage Up to 690 V AC
Mounting Fixed
Main-circuit connection Front terminals
Application High-current low-voltage power distribution

Frequently Asked Questions

What is the ABB 1SDA065762R1?

The ABB 1SDA065762R1 is a 2500 A three-pole SACE Tmax T8L moulded case circuit breaker with a PR332/P-LSIG electronic trip unit for high-current industrial power distribution.

What is the current rating of the ABB 1SDA065762R1?

The ABB 1SDA065762R1 has a rated current (In) of 2500 A.

What trip unit does the ABB 1SDA065762R1 use?

The breaker uses an ABB PR332/P-LSIG electronic trip unit, providing configurable electronic protection for compatible high-current distribution applications.

What does LSIG mean on the ABB PR332/P trip unit?

LSIG identifies long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection functions.

How is the ABB 1SDA065762R1 installed?

The 1SDA065762R1 is a fixed three-pole circuit breaker with front terminals, intended for permanent installation within compatible industrial switchboards and low-voltage power distribution assemblies.

Trusted High-Current Circuit Protection from ABB

ABB SACE Tmax T8 circuit breakers combine high current capacity with advanced electronic protection, providing dependable overload, short-circuit and ground-fault protection for demanding industrial switchboards and low-voltage power distribution systems.