1sda064886r1  t7s 1200 ul pr231/p ls/i=1200a 4 pole abb mccb

1sda064886r1 t7s 1200 ul pr231/p ls/i=1200a 4 pole abb mccb

ABB 1SDA064886R1 Tmax T7S 1200 UL moulded case circuit breaker with PR231/P LS/I electronic release, 1200 A rated current, four-pole fixed configuration, front terminals and stored energy operating mechanism for low-voltage circuit protection.

SKU: 1SDA064886R1Alt SKU: T7S 1200 UL PR231/P LS/I=1200A 4p F F MMPN: 1SDA064886R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA064886R1 Tmax T7S 1200 MCCB?

The ABB 1SDA064886R1 is a high-performance Tmax T7S moulded case circuit breaker designed for reliable low-voltage circuit protection in demanding industrial and commercial power distribution systems. Manufactured by ABB, this fixed four-pole MCCB is built for switchboards, distribution panels and high-current electrical installations requiring dependable protection and robust construction.

This ABB T7S 1200 UL MCCB is fitted with a PR231/P LS/I electronic release, providing long-time, short-time and instantaneous protection functions for effective overload and short-circuit fault management. Its fixed configuration with front terminals and stored energy operating mechanism supports practical integration into low-voltage electrical panels and switchgear assemblies.

With a rated current of 1200 A, a four-pole configuration and robust ABB Tmax construction, the 1SDA064886R1 is suitable for main distribution boards, feeder circuits and industrial switchgear where high current capacity, selective protection and long-term ABB performance are required.

Key Advantages

  • High-current ABB Tmax T7S moulded case circuit breaker.
  • 1200 A rated current for demanding power distribution systems.
  • Four-pole fixed MCCB with front terminal connections.
  • PR231/P LS/I electronic trip unit for long-time, short-time and instantaneous protection.
  • Stored energy operating mechanism for controlled breaker operation.
  • Designed for reliable feeder, switchboard and heavy-load circuit protection.

Key Features

  • ABB Tmax T7S 1200 series.
  • 1200 A nominal current rating.
  • Four-pole circuit breaker.
  • PR231/P LS/I electronic release.
  • Fixed mounting configuration.
  • Front terminal connection.
  • Stored energy operating mechanism.
  • Suitable for industrial switchgear and low-voltage distribution systems.

Reliable Protection for High-Current Distribution Systems

Moulded case circuit breakers such as the ABB Tmax T7S are used to protect low-voltage electrical circuits against overloads and short-circuit faults. The PR231/P LS/I electronic release provides dependable protection functions, helping engineers achieve reliable fault response across industrial power distribution systems.

The 1SDA064886R1 is designed for use in switchgear, main distribution panels and feeder circuits where high current capacity, dependable protection and ABB build quality are required. Its four-pole construction makes it suitable for applications where neutral switching or full four-pole isolation is needed.

Typical Applications

  • Main low-voltage distribution panels.
  • Industrial switchboards and feeder protection.
  • Power distribution in manufacturing facilities.
  • Protection of high-current electrical loads.
  • Commercial and industrial building services.
  • OEM electrical panel and switchgear assemblies.

Technical Specifications

Tick the specs you need, then view products that match.

Current 1200 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Trip Unit Electronic
Manufacturer ABB
Series Tmax T7S
Model T7S 1200 UL PR231/P LS/I In=1200A 4p F F M
Product type Moulded case circuit breaker
Manufacturer part number 1SDA064886R1
EAN 8015644677855
Rated current 1200 A
Number of poles 4 pole
Trip unit PR231/P LS/I
Release type Electronic
Protection functions Long-time, short-time and instantaneous
Mounting type Fixed
Terminal type Front terminals
Operating mechanism Stored energy mechanism
Standards UL
Utilisation Low-voltage circuit protection and power distribution

Frequently Asked Questions

What is the ABB 1SDA064886R1 used for?

The ABB 1SDA064886R1 is used for low-voltage circuit protection in industrial distribution panels, switchboards and high-current electrical systems.

What current rating does this MCCB have?

This ABB Tmax T7S MCCB has a rated current of 1200 A.

How many poles does the 1SDA064886R1 have?

The breaker is a four-pole moulded case circuit breaker.

What trip unit is fitted to this breaker?

The 1SDA064886R1 is fitted with an ABB PR231/P LS/I electronic release.

What type of terminals does this MCCB use?

This model is a fixed breaker with front terminals, designed for installation in electrical panels and switchgear assemblies.

Trusted by Electrical Engineers Worldwide

ABB Tmax moulded case circuit breakers are widely specified by electrical engineers, panel builders and industrial maintenance teams for dependable protection, robust construction and proven performance in low-voltage power distribution systems.