1sda064778r1  t7s 1000 ul pr331/p lsig in=1000a 3 pole abb mccb

1sda064778r1 t7s 1000 ul pr331/p lsig in=1000a 3 pole abb mccb

ABB 1SDA064778R1 SACE Tmax T7S moulded case circuit breaker with PR331/P-LSIG electronic trip unit, 1000 A rated current, three-pole fixed design, stored energy mechanism and front terminals for industrial power distribution.

SKU: 1SDA064778R1Alt SKU: T7S 1000 UL PR331/P LSIG In1000A 3p FF MMPN: 1SDA064778R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA064778R1 Tmax T7S Moulded Case Circuit Breaker?

The ABB 1SDA064778R1 is a high-capacity Tmax T7S moulded case circuit breaker (MCCB) designed for reliable protection in demanding industrial and commercial low voltage power distribution systems. Part of the trusted ABB SACE Tmax T series, this three-pole fixed circuit breaker combines robust construction, advanced electronic protection and dependable switching performance for critical electrical installations.

This model is fitted with the PR331/P-LSIG electronic trip unit, providing long-time, short-time, instantaneous and ground fault protection. This makes it suitable for applications requiring precise protection coordination, improved selectivity and enhanced safety across high-current distribution circuits.

With a 1000 A rated current, 600 V AC rated operational voltage and stored energy operating mechanism, the ABB 1SDA064778R1 is well suited to protecting main feeders, transformers, generators, switchboards and major industrial loads where reliable fault protection is essential.

Key Advantages

  • High-performance ABB Tmax T7S moulded case circuit breaker.
  • 1000 A rated current for demanding industrial power systems.
  • PR331/P-LSIG electronic trip unit with ground fault protection.
  • Long-time, short-time, instantaneous and ground fault protection functions.
  • Three-pole fixed design for industrial distribution boards.
  • Stored energy operating mechanism for reliable switching.
  • Front terminal configuration for efficient panel installation.

Key Features

  • ABB SACE Tmax T7S series.
  • Product ID: 1SDA064778R1.
  • 1000 A rated current.
  • PR331/P-LSIG electronic release.
  • Adjustable LSIG protection for overload, short-circuit and ground fault protection.
  • Three-pole fixed circuit breaker.
  • Fixed front terminal connections.
  • Stored energy operating mechanism.
  • Suitable for UL/CSA low voltage applications.
  • Robust construction for long service life.

Advanced Protection for Critical Power Distribution

The ABB Tmax T7S range is engineered to protect high-current electrical distribution systems where accuracy, durability and operational reliability are essential. Its electronic trip technology helps detect overload, short-circuit and ground fault conditions, supporting safe operation and reducing the risk of equipment damage.

The PR331/P-LSIG trip unit provides flexible protection settings for improved selectivity across low voltage networks. This makes the 1SDA064778R1 a strong choice for panel builders, electrical contractors and industrial facilities requiring robust protection for main distribution circuits and critical loads.

Typical Applications

  • Main low voltage switchboards.
  • Industrial power distribution systems.
  • Motor control centres.
  • Generator protection panels.
  • Transformer protection circuits.
  • Commercial distribution boards.
  • Manufacturing facilities.
  • Critical infrastructure and utility installations.

Technical Specifications

Tick the specs you need, then view products that match.

Current 1000 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T
Model T7S 1000 UL PR331/P LSIG In1000A 3P FF M
Product ID 1SDA064778R1
EAN 8015644676735
Product type Moulded Case Circuit Breaker (MCCB)
Rated current (In) 1000 A
Rated uninterrupted current (Iu) 1000 A
Rated operational voltage 600 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Interrupting capacity 65 kA at 240 V AC, 50 kA at 480 V AC, 25 kA at 600 V AC
Trip unit PR331/P-LSIG electronic release
Protection functions L, S, I and G
Number of poles 3
Short-circuit performance level S
Terminal connection Fixed front terminals
Mounting type Fixed
Protection rating IP20
Operating mechanism Stored energy
Mechanical durability 10,000 operating cycles
Dimensions (H × W × D) 268 × 210 × 178 mm
Weight Approximately 12.5 kg

Frequently Asked Questions

What is the ABB 1SDA064778R1 used for?

It is a moulded case circuit breaker used to protect industrial and commercial low voltage distribution systems against overloads, short circuits and ground faults.

What current rating does this breaker have?

The ABB 1SDA064778R1 has a 1000 A rated current, making it suitable for high-current industrial power distribution applications.

Which trip unit is fitted to this MCCB?

This model is fitted with the ABB PR331/P-LSIG electronic trip unit, providing long-time, short-time, instantaneous and ground fault protection functions.

How many poles does the ABB 1SDA064778R1 have?

The breaker is supplied as a 3-pole fixed circuit breaker with front terminal connections.

Where is this breaker typically installed?

It is commonly installed in industrial switchboards, commercial distribution panels, generator systems, transformer protection circuits and motor control centres.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax moulded case circuit breakers are trusted by panel builders, OEMs and electrical engineers worldwide for dependable circuit protection, advanced electronic trip technology and long-term reliability in demanding power distribution applications.