1sda064773r1  t7s 1000 ul pr332/p li in=1000a 4 pole abb mccb

1sda064773r1 t7s 1000 ul pr332/p li in=1000a 4 pole abb mccb

ABB 1SDA064773R1 SACE Tmax T7S moulded case circuit breaker with PR332/P-LI electronic trip unit, 1000 A rated current and four-pole fixed configuration for industrial power distribution.

SKU: 1SDA064773R1Alt SKU: T7S 1000 UL PR332/P LI In=1000A 4p F FMPN: 1SDA064773R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA064773R1 Tmax T7S Moulded Case Circuit Breaker?

The ABB 1SDA064773R1 is a heavy-duty Tmax T7S moulded case circuit breaker (MCCB) engineered to deliver dependable protection for industrial and commercial low voltage power distribution systems. Part of the trusted ABB SACE Tmax T series, this four-pole breaker combines high interrupting performance with advanced electronic protection, making it ideal for critical electrical installations requiring long-term reliability.

This model is equipped with the intelligent PR332/P-LI electronic trip unit, providing adjustable long-time and instantaneous protection functions for enhanced system protection and improved operational continuity. Its fixed front terminal configuration enables straightforward installation within switchboards, motor control centres and distribution panels.

With a 1000 A rated current, 600 V AC operational voltage and robust four-pole construction, the ABB 1SDA064773R1 is ideally suited to protecting feeders, transformers, generators and major industrial distribution circuits where dependable circuit protection is essential.

Key Advantages

  • High-performance ABB Tmax T7S moulded case circuit breaker.
  • 1000 A rated current for demanding industrial installations.
  • Advanced PR332/P-LI electronic trip unit.
  • Four-pole fixed design for complete circuit isolation.
  • Excellent short-circuit and overload protection.
  • Fixed front terminals simplify installation.
  • Designed for long service life in industrial environments.

Key Features

  • ABB SACE Tmax T7S series.
  • Product ID: 1SDA064773R1.
  • 1000 A rated current.
  • PR332/P-LI electronic release.
  • Long-time and instantaneous protection functions.
  • Four-pole fixed breaker.
  • Front terminal connections.
  • Suitable for industrial low voltage distribution.
  • High mechanical durability.
  • UL/CSA compliant construction.

Reliable Protection for Industrial Power Distribution

The ABB Tmax T7S range is designed to protect critical electrical infrastructure by delivering accurate electronic protection against overloads and fault conditions. Its advanced trip technology improves installation reliability while helping minimise downtime and protect valuable equipment.

With its robust construction and configurable electronic protection, the 1SDA064773R1 is well suited to industrial manufacturing, utilities, commercial facilities and OEM switchgear applications where dependable performance is required.

Typical Applications

  • Main low voltage switchboards.
  • Industrial power distribution systems.
  • Motor control centres.
  • Generator protection.
  • Transformer protection.
  • Commercial buildings.
  • Manufacturing facilities.
  • Critical infrastructure installations.

Technical Specifications

Tick the specs you need, then view products that match.

Current 1000 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T
Model T7S 1000 UL PR332/P LI In1000A 4P FF
Product ID 1SDA064773R1
Product type Moulded Case Circuit Breaker (MCCB)
Rated current (In) 1000 A
Rated uninterrupted current (Iu) 1000 A
Rated operational voltage 600 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Trip unit PR332/P-LI electronic release
Number of poles 4
Terminal connection Fixed front terminals
Protection rating IP20
Mechanical durability 10,000 operating cycles
Dimensions (H × W × D) Approx. 268 × 280 × 154 mm
Weight Approx. 12.5 kg

Frequently Asked Questions

What is the ABB 1SDA064773R1 used for?

It is a moulded case circuit breaker designed to protect industrial electrical distribution systems against overloads and short circuits.

What current rating does this circuit breaker have?

The breaker has a 1000 A rated current for high-power industrial applications.

What trip unit is fitted?

This breaker is fitted with the ABB PR332/P-LI electronic trip unit, providing long-time and instantaneous protection functions.

How many poles does this breaker have?

The ABB 1SDA064773R1 is supplied as a 4-pole fixed circuit breaker with front terminal connections.

Where is this breaker typically installed?

It is commonly installed in industrial switchboards, distribution boards, generator systems and motor control centres.

Trusted by Electrical Professionals Worldwide