1SDA063072R1 ABB T7L 1600 PR332/P LSIRc 1600A 4P Circuit Breaker

1SDA063072R1 ABB T7L 1600 PR332/P LSIRc 1600A 4P Circuit Breaker

ABB 1SDA063072R1 is a SACE Tmax T7L 1600 A four-pole fixed moulded-case circuit breaker with a PR332/P LSIRc electronic trip unit and 120 kA ultimate short-circuit breaking capacity at 380–415 V AC for comprehensive overload, short-circuit and residual-current protection.

SKU: 1SDA063072R1MPN: 1SDA063072R1
Price
List Price £20,811.16 ex VAT
Your Price (ex VAT) Save 25%
£15,608.37 25% OFF
You save £5,202.79 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £15,608.37
Trade pricing is personalised to your account

Manufacturer Lead Time

£15,608.37

Why Choose the ABB T7L 1600 PR332/P LSIRc 1600A Circuit Breaker?

The ABB 1SDA063072R1, designated T7L 1600 PR332/P LSIRc In=1600A 4p F F, is a high-performance four-pole moulded-case circuit breaker (MCCB) designed for demanding low-voltage power distribution systems. Part of the established ABB SACE Tmax T7 series, it combines a rated uninterrupted current of 1600 A with the advanced PR332/P LSIRc solid-state electronic trip unit.

The T7L performance level provides substantial fault interruption capability, with an ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC. The PR332/P LSIRc release provides long-time, short-time and instantaneous protection together with residual-current protection, delivering comprehensive protection against overloads, short circuits and earth leakage conditions.

Configured as a fixed four-pole breaker with front terminals, the 1SDA063072R1 uses a manual lever operating mechanism and is suitable for three-phase and neutral distribution networks. Its combination of 1600 A current capability, four-pole switching, electronic LSIRc protection and high breaking capacity makes it particularly suitable for industrial, commercial and infrastructure power distribution.

Key Advantages

  • High-current 1600 A moulded-case circuit breaker for demanding low-voltage distribution systems.
  • 120 kA ultimate short-circuit breaking capacity at 380–415 V AC.
  • Advanced PR332/P LSIRc solid-state electronic trip unit.
  • Combines long-time, short-time and instantaneous protection with residual-current protection.
  • Four-pole configuration suitable for three-phase and neutral distribution networks.
  • Fixed construction with front terminals and manual lever operation for dependable switchboard integration.

Key Features

  • ABB SACE Tmax T7L 1600 series.
  • 1600 A rated uninterrupted current.
  • PR332/P LSIRc electronic protection trip unit.
  • LSIRc protection: long-time, short-time, instantaneous and residual-current protection.
  • 120 kA Icu at 380–415 V AC.
  • Four-pole configuration.
  • 640–1600 A adjustable long-time overload range.
  • 2400–24000 A short-circuit protection adjustment range.
  • Residual-current protection for enhanced earth-leakage fault detection.
  • Rated operational voltage up to 690 V AC.
  • Fixed installation with front main-circuit terminals.
  • Manual lever operating mechanism.

Advanced Overload, Short-Circuit and Residual-Current Protection

The ABB Tmax T7L platform is engineered for high-current low-voltage systems where substantial fault interruption capability and configurable electronic protection are required. With a rated uninterrupted current of 1600 A and an ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, the 1SDA063072R1 provides robust protection for main distribution circuits and high-current feeders.

The PR332/P LSIRc electronic trip unit combines long-time overload, short-time and instantaneous short-circuit protection with residual-current protection. This enables the breaker to respond to a broad range of electrical fault conditions while its four-pole construction makes it particularly suitable for three-phase and neutral distribution systems requiring comprehensive high-current circuit protection.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process plants.
  • Commercial buildings and infrastructure installations.
  • Transformer secondary and high-current feeder protection.
  • Three-phase and neutral distribution networks.
  • High fault-level systems requiring integrated residual-current protection.

Technical Specifications

Series SACE Tmax T7
ABB order code 1SDA063072R1
ABB product group 310511-T-Max T4 - T8
EAN / GTIN 8015644656218
Product type Moulded-case circuit breaker (MCCB)
Frame T7L 1600
Short-circuit performance level L
Rated uninterrupted current Iu 1600 A
Number of poles 4
Trip unit PR332/P LSIRc
Release type Solid-state electronic
Protection functions LSIRc – long-time, short-time, instantaneous and residual-current protection
Long-time overload setting range 640–1600 A
Short-circuit protection adjustment up to 24000 A
Residual-current protection Integrated
Rated operational voltage up to 690 V AC
Ultimate short-circuit breaking capacity Icu at 220–230 V AC 200 kA
Ultimate short-circuit breaking capacity Icu at 380–415 V AC 120 kA
Ultimate short-circuit breaking capacity Icu at 440 V AC 100 kA
Ultimate short-circuit breaking capacity Icu at 500 V AC 85 kA
Ultimate short-circuit breaking capacity Icu at 690 V AC 50 kA
Service short-circuit breaking capacity Ics at 380–415 V AC 120 kA
Service short-circuit breaking capacity Ics at 440 V AC 100 kA
Service short-circuit breaking capacity Ics at 500 V AC 64 kA
Service short-circuit breaking capacity Ics at 690 V AC 37.5 kA
Rated short-time withstand current Icw 20 kA for 1 s
Installation Fixed
Terminal position Front
Operating mechanism Manual lever
Dimensions (W × H × D) 280 × 268 × 154 mm
Net weight 12.5 kg

Frequently Asked Questions

What is the ABB 1SDA063072R1 used for?

The ABB 1SDA063072R1 is a 1600 A four-pole moulded-case circuit breaker designed for switching and protection against overload, short-circuit and residual-current faults in high-current low-voltage power distribution systems.

What trip unit is fitted to the ABB T7L 1600 1SDA063072R1?

The breaker is fitted with an ABB PR332/P LSIRc solid-state electronic trip unit, providing long-time, short-time, instantaneous and residual-current protection functions.

What is the breaking capacity of the ABB 1SDA063072R1?

The ABB T7L 1600 1SDA063072R1 has an ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, with an Icu of 200 kA at 220–230 V AC and 50 kA at 690 V AC.

What does LSIRc mean on the PR332/P trip unit?

LSIRc denotes long-time, short-time, instantaneous and residual-current protection, providing comprehensive electronic protection against overloads, short circuits and residual-current or earth-leakage faults.

Where is the ABB 1SDA063072R1 typically installed?

The breaker is typically installed in main low-voltage switchboards, industrial distribution panels, transformer secondary circuits and infrastructure power systems requiring 1600 A four-pole protection, high short-circuit interruption performance and integrated residual-current protection.

Trusted Protection from ABB

ABB Tmax moulded-case circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems, providing dependable circuit protection, flexible electronic trip functionality and high short-circuit interruption performance.